A HIGH TEMPERATURE HIGH BANDWIDTH FAST RESPONSE TOTAL PRESSURE PROBE FOR MEASUREMENTS IN A MULTISTAGE AXIAL COMPRESSOR

被引:0
|
作者
Mersinligil, Mehmet [1 ]
Brouckaert, Jean-Francois [1 ]
Courtiade, Nicolas
Ottavy, Xavier
机构
[1] von Karman Inst Fluid Dynam, Turbomachinery & Prop Dept, B-1640 Rhode St Genese, Belgium
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Over the last decades, fast response aerodynamic probes have been recognized as a robust measurement technique to provide time-resolved flow field data in turbomachinery environments. Still, most of the existing probe designs are restricted to low temperature applications (< 120 degrees C) either because of sensor temperature range limitations or packaging issues. Measurements in turbomachines also require a small probe size often with a very high bandwidth which are conflictual constraints difficult to satisfy simultaneously. This contribution therefore presents the development of a novel miniature (empty set 2.5 mm) high temperature single sensor total pressure probe, designed for operation up to 250 degrees C with a very high bandwidth of 250 kHz. The probe main element is a 1.7 mm diameter commercial piezoresistive transducer placed in a Pitot type arrangement with a flush mounted sensor to provide the highest bandwidth. The details of the probe design are presented as well as the probe calibrations in pressure and in temperature. The effects of using a thermal compensation module or a sense resistor to monitor the temperature drift are described in the context of measurement uncertainty. The probes were characterized in terms of aerodynamic characteristics versus flow angle and Mach number Shock tube tests have shown a dynamic response of the probe with sensor resonance frequencies well over 300 kHz, with a flat frequency range up to 250 kHz. Two probe prototypes were manufactured and first used in the 31/2-stage high speed axial compressor CREATE of the LMFA at Ecole Centrale de Lyon in France. The probes were traversed at each inter blade row plane up to temperatures of 180 degrees C and absolute pressure of 3 bar The probe was able to resolve the high blade passing frequencies (similar to 16 kHz) and several harmonics including rotor-stator interaction frequencies up to 200 kHz. Besides the average total pressure distributions from the radial traverses, phase-locked averages and random unsteadiness are presented. The probe spatial and temporal resolutions are discussed in the context of those results.
引用
收藏
页码:117 / 131
页数:15
相关论文
共 50 条
  • [41] A FAST-RESPONSE HIGH-TEMPERATURE HIGH-PRESSURE SURFACE THERMOCOUPLE
    CHARLES, E
    LORIVAL, R
    BOYER, A
    MALBRUNOT, P
    SENSORS AND ACTUATORS, 1984, 6 (02): : 135 - 142
  • [42] High-Temperature-High-Pressure NMR Probe for Self-Diffusion Measurements in Molten Salts
    Matenaar, U.
    Richter, J.
    Zeidler, M. D.
    Journal of Magnetic Resonance - Series A, 122 (01):
  • [43] NMR PROBE FOR HIGH-PRESSURE AND HIGH-TEMPERATURE
    DELANGEN, M
    PRINS, KO
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (11): : 5218 - 5221
  • [44] Unsteady Pressure Measurements in a High-Speed Centrifugal Compressor
    N.Bulot
    X.Ottavy
    I.Trebinjac
    JournalofThermalScience, 2010, 19 (01) : 34 - 41
  • [45] Rheology measurements at high pressure and temperature
    Weidner, DJ
    Wang, YB
    Chen, GL
    Ando, J
    Vaughan, MT
    PROPERTIES OF EARTH AND PLANETARY MATERIALS AT HIGH PRESSURE AND TEMPERATURE, 1998, 101 : 473 - 482
  • [46] Unsteady Pressure Measurements in a High-Speed Centrifugal Compressor
    Bulot, N.
    Ottavy, X.
    Trebinjac, I.
    JOURNAL OF THERMAL SCIENCE, 2010, 19 (01) : 34 - 41
  • [47] Unsteady pressure measurements in a high-speed centrifugal compressor
    N. Bulot
    Xavier Ottavy
    I. Trebinjac
    Journal of Thermal Science, 2010, 19 : 34 - 41
  • [48] PROBE MEASUREMENTS IN HIGH-CURRENT HIGH-PRESSURE ARC
    BAKSHT, FG
    BORODIN, VS
    VORONOV, AM
    ZHURAVLEV, VN
    RUTBERG, FG
    ZHURNAL TEKHNICHESKOI FIZIKI, 1990, 60 (11): : 190 - 193
  • [49] RHEOLOGY MEASUREMENTS AT HIGH PRESSURE AND TEMPERATURE
    Ando, J.
    Weidner, D. J.
    Wang, Y.
    Chen, G.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C543 - C543
  • [50] Study on the total pressure and total temperature distortion of axial flow compressor based on different rain ingestion forms
    Yu, Yonghao
    Chu, Shuguang
    Wang, Ziyi
    Ooi, Kim Tiow
    Luo, Mingcong
    Zheng, Qun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2024,