The CO Concentrations Research Based on the Gaussian Plume Diffusion Model of the High-rise Building Fire Smoke

被引:0
|
作者
Jiang Wei [1 ]
Wei Yuan [1 ]
Hou Long-fei
机构
[1] Zhongnan Univ Econ & Law, Sch Informat & Safety Engn, Wuhan, Peoples R China
关键词
CO concentrations; Fitting analysis; Gas diffusion; High-rise building fire;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
For the sake of measuring the safety distance of high-rise buildings fires in theory, based on Bei-pei building fire, using fire dynamic software-FDS to build the high-rise building fire epidermis model, combining with the Gaussian model which is widespread applied in environmental monitoring, do normal distribution hypothesis on the high temperature flue gas in fire, and exports hypothesis function. Then count the CO concentrations in a high plane x axis after the fire turns into the stable stage. By means of statics analysis software-SPSS, according to export function, do a fitting analysis to get the distribution function about the concentration of CO. From the correlation inspection, get the goodness of fit which was 0.996, this meets the normal distribution hypothesis. The experimental results provide the basis to research further flue gas diffusion mode function by using normal distribution hypothesis.
引用
收藏
页码:420 / 425
页数:6
相关论文
共 50 条
  • [21] Fire and Smoke Protection Measures for High-Rise Buildings
    Murakami, Suminao
    Murosaki, Yoshiteru
    [J]. JOURNAL OF DISASTER RESEARCH, 2011, 6 (06) : 629 - 643
  • [22] Simulation of fire and evacuation in high-rise building
    Xing Zhixiang
    Tang Yong
    [J]. 2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 705 - 709
  • [23] Research on Blasting Vibration Response of High-rise Building Based on Model Simplification
    Wang L.-T.
    Gao W.-X.
    Zhang F.-C.
    Cao X.-L.
    [J]. 2018, China Ordnance Industry Corporation (39): : 121 - 134
  • [24] The effect of damper leakage and fire size on the performance of smoke control system in high-rise building
    Kun Hyuk Sung
    Hyun Ju Shin
    Dabin Baek
    Hong Sun Ryou
    [J]. Journal of Mechanical Science and Technology, 2017, 31 : 4029 - 4034
  • [25] The effect of damper leakage and fire size on the performance of smoke control system in high-rise building
    Sung, Kun Hyuk
    Shin, Hyun Ju
    Baek, Dabin
    Ryou, Hong Sun
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (08) : 4029 - 4034
  • [26] Performance assessment of stairwell smoke prevention techniques in a model high-rise building
    Sharma, Ankit
    Mishra, Kirti Bhushan
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53
  • [27] Study on Smoke-proof Measures of Elevator Evacuation During High-rise Building Fire
    Liu, Jianmin
    [J]. ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 914 - 917
  • [28] High-rise building fire pre-warning model based on the support vector regression
    张立宁
    张奇
    安晶
    [J]. Journal of Beijing Institute of Technology, 2015, 24 (03) : 285 - 290
  • [29] High-rise building fire pre-warning model based on the support vector regression
    State Key Laboratory of Explosion Science and Technology, Beijing Institute of Technology, Beijing
    100081, China
    不详
    101601, China
    [J]. J Beijing Inst Technol Engl Ed, 3 (285-290):
  • [30] Evaluating method for fire prevention of high-rise building
    Wang Rui
    Jin Shan
    Zhang Xiangyang
    Zhuang Damin
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 686 - 689