Safety and Efficacy of a Bolus Injection of Landiolol Hydrochloride as a Premedication for Multidetector-Row Computed Tomography Coronary Angiography

被引:22
|
作者
Osawa, Kazuhiro [1 ]
Miyoshi, Toru [2 ]
Sato, Shuhei [3 ]
Akagi, Noriaki [3 ]
Morimitsu, Yusuke [3 ]
Nakamura, Kazufumi [1 ]
Kohno, Kunihisa [1 ]
Kusano, Kengo [1 ]
Kanazawa, Susumu [3 ]
Ito, Hiroshi [1 ]
机构
[1] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Cardiovasc Med, Okayama 7008558, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Cardiovasc Therapeut, Okayama 7008558, Japan
[3] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Radiol, Okayama 7008558, Japan
关键词
beta-blocker; Coronary angiography; Landiolol; Multidetector-row computed tomography; ATRIAL-FIBRILLATION; BETA-BLOCKER; NONINVASIVE ASSESSMENT; CARDIAC-FUNCTION; ARTERY-DISEASE; IMAGE QUALITY; CT; ESMOLOL;
D O I
10.1253/circj.CJ-12-0663
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We evaluated the safety and efficacy of a bolus injection of landiolol hydrochloride, an ultrashort-acting beta 1-selective antagonist, as an additional treatment after premedication with an oral p-blocker to reduce heart rate prior to multidetector-row computed tomography (MDCT) coronary angiography (CAG). Methods and Results: A total of 458 patients who underwent MDCT CAG were retrospectively enrolled. Image quality and hemodynamic parameters were compared in patients before and after approval of landiolol hydrochloride. If heart rate reduction was insufficient after premedication with an oral beta-blocker, a bolus injection of landiolol hydrochloride (n=66) or other drugs (n=30) was used. The percentage of evaluable images per segment in patients after approval of landiolol (99.3%) was greater than that in patients before approval of landiolol (97.4%, P<0.01). Heart rates before scanning in patients receiving landiolol hydrochloride were similar to those receiving other drugs. Heart rate was significantly reduced approximately 5 min after injection of landiolol hydrochloride and increased shortly. No decrease in systolic blood pressure or other adverse effects was observed. Conclusions: Bolus injection of landiolol hydrochloride sufficiently reduced heart rate without significantly reducing systolic blood pressure and produced a high percentage of evaluable images, suggesting that bolus injection of landiolol hydrochloride as an additional pretreatment is feasible in MDCT CAG. (Circ J 2013; 77:146-152)
引用
收藏
页码:146 / 152
页数:7
相关论文
共 50 条
  • [1] Bolus Injection of Landiolol Hydrochloride, Ultrashort-Acting β1-Selective Antagonist, is Excellent Premedication for Multidetector-Row Computed Tomography Coronary Angiography
    Osawa, Kazuhiro
    Miyoshi, Toru
    Nagase, Satoshi
    Nakamura, Kazufumi
    Kohno, Kunihisa
    Morita, Hiroshi
    Kusano, Kengo
    Ito, Hiroshi
    CIRCULATION, 2012, 126 (21)
  • [2] Landiolol Hydrochloride: A New Premedication for Multislice Computed Tomography Coronary Angiography
    Isobe, Satoshi
    Ando, Hirohiko
    Takeuchi, Toyonari
    Sato, Kimihide
    Ohashi, Toshio
    Kobayashi, Mikiko
    Ishii, Hideki
    Murohara, Toyoaki
    CIRCULATION, 2010, 122 (21)
  • [3] Efficacy of bolus injections of landiolol hydrochloride as premedication in coronary artery CT angiography
    Barwig, Mark
    Janisch, Michael
    Gessl, Johannes
    Kuebler, Wolfgang
    Koenig, Christopher
    Schwantzer, Gerold
    Schoellnast, Helmut
    INSIGHTS INTO IMAGING, 2025, 16 (01):
  • [4] Multidetector-row computed tomography of coronary atherosclerosis
    Nikolaou, K
    Becker, CR
    Wintersperger, BJ
    Rist, C
    Trumm, C
    Leber, A
    Babaryka, G
    Reiser, MF
    RADIOLOGE, 2004, 44 (02): : 130 - +
  • [5] Multidetector-row computed tomography
    El-Khoury, GY
    Bennett, DL
    Ondr, GJ
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (01) : 1 - 5
  • [6] Feasibility and safety of intravenous administration of landiolol hydrochloride in multislice computed tomography coronary angiography
    Isobe, S.
    Sato, K.
    Sugiura, K.
    Mimura, T.
    Kobayashi, M.
    Meno, C.
    Kato, M.
    Ishii, H.
    Murohara, T.
    EUROPEAN HEART JOURNAL, 2008, 29 : 244 - 244
  • [7] Feasibility and Safety of Intravenous Administration of Landiolol Hydrochloride in Multislice Computed Tomography Coronary Angiography
    Isobe, S.
    Sato, K.
    Sugiura, K.
    Mimura, T.
    Kobayashi, M.
    Meno, C.
    Kato, M.
    Ishii, H.
    Murohara, T.
    CURRENT ADVANCES IN HEART DISEASE, 2008, : 107 - 114
  • [8] Usefulness of multidetector-row computed tomography
    Su, Chieh-Shou
    Tsai, I-Chen
    Lin, Wei-Wen
    Lee, Tain
    Ting, Chih-Tai
    Liang, Kae-Woei
    TEXAS HEART INSTITUTE JOURNAL, 2008, 35 (03) : 349 - 351
  • [9] Occlusion of coronary aneurysms demonstrated by multidetector-row computed tomography
    Komatsu, S.
    Achenbach, S.
    Ropers, D.
    Daniel, W. G.
    Ueda, Y.
    Pflederer, T.
    Kuhlmann, A.
    Wechsel, M.
    Hirayama, A.
    Kodama, K.
    CLINICAL RESEARCH IN CARDIOLOGY, 2007, 96 (08) : 575 - 578
  • [10] Occlusion of coronary aneurysms demonstrated by multidetector-row computed tomography
    Sei Komatsu
    Stephan Achenbach
    Dieter Ropers
    Werner G. Daniel
    Yasunori Ueda
    Tobias Pflederer
    Alexander Kuhlmann
    Martin Wechsel
    Atsushi Hirayama
    Kazuhisa Kodama
    Clinical Research in Cardiology, 2007, 96 : 575 - 578