EXPERIMENTAL INVESTIGATION ON FLUID FLOW IN AN INCLINED OPEN RECTANGULAR MICROGROOVES HEAT SINK WITH MICRO-PIV

被引:0
|
作者
Yu, Dong [1 ]
Hu, Xuegong [1 ]
Guo, Chaohong [1 ]
Tang, Dawei [1 ]
Sun, Fangyuan [1 ]
Hu, Linghong [2 ]
Gao, Fei [2 ]
Zhao, Tao [3 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
[2] Guizhou Yonghong Aviat Machinery Co, Guiyang 550025, Peoples R China
[3] Wuxi Mashan Yonghong Heat Exchanger Co Ltd, Wuxi 214092, Peoples R China
关键词
micro-PIV; rectangular microgroove; velocity profile; accommodation stage; corner flow stage; MODEL;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The paper investigates the fluid flow in an inclined open rectangular microgrooves heat sink using La Vision-assembled micro-PlV system. The images of the accommodation stage and the corner flow stage at inclined 15 degrees angle with heat flux of 0.09W/cm(2) were recorded by a CCD camera with the speed of 10 frames per second The velocity profile at inclined 15 degrees angle with heat flux of 0.14W/cm(2) was acquired by using the analyzing software DaVis 8.1. In accommodation stage, X-Y-Z scanning table was adjusted vertically and horizontally to investigate the velocity field of different focused planes. Results show that the experimental images of the accommodation stage and the corner flow stage verify) the predictions proposed by Catton and Stroes that there exist accommodation stage and corner flow stage and no jump-like stage proposed by Nilson et al. Flow in microgroove driven by capillary force is very slow and the velocity is less than 1mm per second In evaporating thin film region, from the left side to the right side of the microgroove, the velocity increases and velocity of the interface is the highest. In lower meniscus region, the velocity increases and then decreases.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Experimental investigation on flow characteristics in open rectangular microgrooves using micro-PIV
    Yu, Dong
    Guo, Chaohong
    Xie, Ningning
    Wang, Tao
    Hu, Xuegong
    Tang, Dawei
    [J]. APPLIED THERMAL ENGINEERING, 2016, 106 : 906 - 915
  • [2] EXPERIMENTAL INVESTIGATION ON SHAPE OF THE MENISCUS IN OPEN RECTANGULAR MICROGROOVES HEAT SINKS WITH MICRO-PIV
    Yu, Dong
    Hu, Xuegong
    Guo, Chaohong
    Tang, Dawei
    Nie, Xuelei
    Hu, Linghong
    Gao, Fei
    Zhao, Tao
    [J]. PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2013, 2013,
  • [3] Investigation on meniscus shape and flow characteristics in open rectangular microgrooves heat sinks with micro-PIV
    Yu, Dong
    Hu, Xuegong
    Guo, Chaohong
    Wang, Tao
    Xu, Xianfeng
    Tang, Dawei
    Nie, Xuelei
    Hu, Linghong
    Gao, Fei
    Zhao, Tao
    [J]. APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 716 - 727
  • [4] Study on the characteristics of the capillary wetting and flow in open rectangular microgrooves heat sink
    Tang, Jinchen
    Yu, Yingying
    Hu, Xuegong
    Mo, Xiaobao
    Zhou, Wenbin
    Dai, Xinlong
    Shan, Long
    Yu, Dong
    [J]. APPLIED THERMAL ENGINEERING, 2018, 143 : 90 - 99
  • [5] Micro-PIV of viscoelastic fluid flow in media
    Ibezim, Victor C.
    Dennis, David J. C.
    Poole, Robert J.
    [J]. JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2024, 332
  • [6] Micro-PIV investigation of the internal flow transitions inside droplets traveling in a rectangular microchannel
    Liu, Zhaomiao
    Zhang, Longxiang
    Pang, Yan
    Wang, Xiang
    Li, Mengqi
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2017, 21 (12)
  • [7] Micro-PIV investigation of the internal flow transitions inside droplets traveling in a rectangular microchannel
    Zhaomiao Liu
    Longxiang Zhang
    Yan Pang
    Xiang Wang
    Mengqi Li
    [J]. Microfluidics and Nanofluidics, 2017, 21
  • [8] Experimental Investigation on Flow Characteristics of Chicken Blood in a Micro Tube Using a Micro-PIV Technique
    Yeo, Chang Sub
    Ji, Ho Seong
    Lee, Sang Joon
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (11) : 1027 - 1034
  • [9] In vitro blood flow in a rectangular PDMS microchannel:: experimental observations using a confocal micro-PIV system
    Lima, Rui
    Wada, Shigeo
    Tanaka, Shuji
    Takeda, Motohiro
    Ishikawa, Takuji
    Tsubota, Ken-ichi
    Imai, Yohsuke
    Yamaguchi, Takami
    [J]. BIOMEDICAL MICRODEVICES, 2008, 10 (02) : 153 - 167
  • [10] In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system
    Rui Lima
    Shigeo Wada
    Shuji Tanaka
    Motohiro Takeda
    Takuji Ishikawa
    Ken-ichi Tsubota
    Yohsuke Imai
    Takami Yamaguchi
    [J]. Biomedical Microdevices, 2008, 10 : 153 - 167