In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system

被引:0
|
作者
Rui Lima
Shigeo Wada
Shuji Tanaka
Motohiro Takeda
Takuji Ishikawa
Ken-ichi Tsubota
Yohsuke Imai
Takami Yamaguchi
机构
[1] Tohoku University,Department of Bioengineering and Robotics, Graduate School of Engineering
[2] ESTiG,Department of Mechanical Tech
[3] Braganca Polyt.,Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science
[4] Osaka University,Department of Nanomechanics, Graduate School of Engineering
[5] Tohoku University,Division of Surgical Oncology, Graduate School of Medicine
[6] Tohoku University,Yamaguchi and Ishikawa Lab. (PFSL), Department of Bioengineering and Robotics, Graduate School of Engineering
[7] Tohoku University,undefined
来源
Biomedical Microdevices | 2008年 / 10卷
关键词
Microcirculation; Confocal micro-PIV; PDMS microchannel; Red blood cells; Mesoscopic blood flow;
D O I
暂无
中图分类号
学科分类号
摘要
Progress in microfabricated technologies has attracted the attention of researchers in several areas, including microcirculation. Microfluidic devices are expected to provide powerful tools not only to better understand the biophysical behavior of blood flow in microvessels, but also for disease diagnosis. Such microfluidic devices for biomedical applications must be compatible with state-of-the-art flow measuring techniques, such as confocal microparticle image velocimetry (PIV). This confocal system has the ability to not only quantify flow patterns inside microchannels with high spatial and temporal resolution, but can also be used to obtain velocity measurements for several optically sectioned images along the depth of the microchannel. In this study, we investigated the ability to obtain velocity measurements using physiological saline (PS) and in vitro blood in a rectangular polydimethysiloxane (PDMS) microchannel (300 μm wide, 45 μm deep) using a confocal micro-PIV system. Applying this combination, measurements of trace particles seeded in the flow were performed for both fluids at a constant flow rate (Re = 0.02). Velocity profiles were acquired by successive measurements at different depth positions to obtain three-dimensional (3-D) information on the behavior of both fluid flows. Generally, the velocity profiles were found to be markedly blunt in the central region, mainly due to the low aspect ratio (h/w = 0.15) of the rectangular microchannel. Predictions using a theoretical model for the rectangular microchannel corresponded quite well with the experimental micro-PIV results for the PS fluid. However, for the in vitro blood with 20% hematocrit, small fluctuations were found in the velocity profiles. The present study clearly shows that confocal micro-PIV can be effectively integrated with a PDMS microchannel and used to obtain blood velocity profiles along the full depth of the microchannel because of its unique 3-D optical sectioning ability. Advantages and disadvantages of PDMS microchannels over glass capillaries are also discussed.
引用
收藏
页码:153 / 167
页数:14
相关论文
共 50 条
  • [1] In vitro blood flow in a rectangular PDMS microchannel:: experimental observations using a confocal micro-PIV system
    Lima, Rui
    Wada, Shigeo
    Tanaka, Shuji
    Takeda, Motohiro
    Ishikawa, Takuji
    Tsubota, Ken-ichi
    Imai, Yohsuke
    Yamaguchi, Takami
    [J]. BIOMEDICAL MICRODEVICES, 2008, 10 (02) : 153 - 167
  • [2] Velocity measurements of blood flow in a rectangular PDMS microchannel assessed by confocal micro-PIV system
    Lima, Rui
    Wada, Shigeo
    Tanaka, Shuji
    Takeda, Motohiro
    Tsubota, Ken-Ichi
    Ishikawa, Takuji
    Yamaguchi, Takami
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 283 - +
  • [3] Micro-PIV measurements of blood flow in a microchannel
    Park, CW
    Kim, GB
    Lee, SJ
    [J]. OPTICAL DIAGNOSTICS AND SENSING IV, 2004, 5325 : 70 - 77
  • [4] Confocal micro-PIV velocity measurements of physiological fluids in a rectangular microchannel
    Lima, R
    Wada, S
    Tsubota, K
    Yamaguchi, T
    [J]. PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 301 - 306
  • [5] Velocity fields of blood flow in microchannels using a confocal micro-PIV system
    Lima, Rui
    Ishikawa, Takuji
    Tanaka, Shuji
    Takeda, Motohiro
    Tsubota, Ken-Ichi
    Wada, Shigeo
    Yamaguchi, Takami
    [J]. FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS, 2006, : 973 - +
  • [6] In vitro confocal micro-PIV measurements of blood flow in a square microchannel: The effect of the haematocrit on instantaneous velocity profiles
    Lima, Rui
    Wada, Shigeo
    Takeda, Motohiro
    Tsubota, Ken-ichi
    Yamaguchi, Takami
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (12) : 2752 - 2757
  • [7] Experimental investigation on flow characteristics in open rectangular microgrooves using micro-PIV
    Yu, Dong
    Guo, Chaohong
    Xie, Ningning
    Wang, Tao
    Hu, Xuegong
    Tang, Dawei
    [J]. APPLIED THERMAL ENGINEERING, 2016, 106 : 906 - 915
  • [8] Velocity measurement of flow in the microchannel with barriers using micro-PIV
    Wang, RJ
    Lin, JZ
    Xie, HB
    [J]. JOURNAL OF VISUALIZATION, 2006, 9 (02) : 209 - 217
  • [9] Velocity measurement of flow in the microchannel with barriers using Micro-PIV
    R. J. Wang
    J. Z. Lin
    H. B. Xie
    [J]. Journal of Visualization, 2006, 9 : 209 - 217
  • [10] Micro-PIV investigation of the internal flow transitions inside droplets traveling in a rectangular microchannel
    Liu, Zhaomiao
    Zhang, Longxiang
    Pang, Yan
    Wang, Xiang
    Li, Mengqi
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2017, 21 (12)