TES microcalorimeter development for future Japanese X-ray astronomy missions

被引:3
|
作者
Fujimoto, R
Mitsuda, K
Yamasaki, NY
Iyomoto, N
Oshima, T
Takei, Y
Futamoto, K
Ichitsubo, T
Fujimori, T
Yoshida, K
Ishisaki, Y
Morita, U
Koga, T
Shinozaki, K
Sato, K
Takai, N
Ohashi, T
Kudo, H
Sato, H
Arakawa, T
Kobayashi, H
Izumi, T
Ohtsuka, S
Mori, K
Shoji, S
Osaka, T
Homma, T
Kuroda, Y
Onishi, M
Goto, M
Beppu, F
Tanaka, T
Morooka, T
Nakayama, S
Chinone, K
机构
[1] ISAS, Sagamihara, Kanagawa 2298510, Japan
[2] Tokyo Metropolitan Univ, Tokyo 1920397, Japan
[3] Waseda Univ, Tokyo 1698555, Japan
[4] Mitsubishi Heavy Ind Co Ltd, Aichi 4858561, Japan
[5] Panason Commun Co LTD, Kumamoto 8650193, Japan
[6] Seiko Instruments Inc, Matsudo, Chiba 2702222, Japan
关键词
X-ray astronomy; microcalorimeter; transition edge sensor;
D O I
10.1016/j.nima.2003.11.356
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We are developing a Ti/Au TES microcalorimeter array for future Japanese X-ray astronomy missions. The goal is an energy resolution of 2-5 eV at 6 keV, and an array of 100-1000 pixels to achieve a geometrical area of >1 cm(2) and a moderate spatial resolution simultaneously. The energy resolution was improved to similar to6 eV at 6 keV with a very fast time constant (<100 mus). To achieve a high coverage fraction, it is necessary to fabricate mushroom-shaped X-ray microabsorbers. We are developing an electrodeposition fabrication technique that is suitable for our process. Sn was used as absorber material, but the energy resolution was not good due to the existence of long-lived quasiparticles. Bi is also used, and the process is under optimization now. The readout strategy is to multiplex signals in the frequency domain, using a bridge circuit. So far, we succeeded in multiplexing two pixels modulated with 50 and 20 kHz at 440 mK. The energy resolution obtained at 110 mK was 33 eV (25 kHz). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:431 / 434
页数:4
相关论文
共 50 条
  • [21] A TES X-ray microcalorimeter-array for imaging spectroscopy
    de Korte, PAJ
    Hoevers, HFC
    den Herder, JWA
    Bleeker, JAM
    Tiest, WMB
    Bruijn, MP
    Ridder, ML
    Wiegerink, RJ
    Kaastra, JS
    van der Kuur, J
    Mels, WA
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 779 - 789
  • [22] Processing pulses from TES microcalorimeter X-ray detectors
    Thurgate, Stephen
    Jach, Terrence
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021, 1014
  • [23] Development of a high energy resolution X-ray microcalorimeter using Ti/Au TES
    Kudo, H
    Yokoyama, Y
    Shoji, S
    DESIGN, CHARACTERIZATION, AND PACKAGING FOR MEMS AND MICROELECTRONICS, 1999, 3893 : 241 - 249
  • [24] X-RAY ASTRONOMY IN THE FUTURE
    CULHANE, JL
    SPACE SCIENCE REVIEWS, 1981, 30 (1-4) : 537 - 564
  • [25] Development of Dielectric X-Ray Microcalorimeter
    Sekiya, N.
    Yamasaki, N. Y.
    Mitsuda, K.
    Kawasaki, S.
    Takei, Y.
    Yoshitake, H.
    Sakai, K.
    Sato, K.
    Maehata, K.
    Takashima, H.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (3-4) : 435 - 441
  • [26] Development of Dielectric X-Ray Microcalorimeter
    N. Sekiya
    N. Y. Yamasaki
    K. Mitsuda
    S. Kawasaki
    Y. Takei
    H. Yoshitake
    K. Sakai
    K. Sato
    K. Maehata
    H. Takashima
    Journal of Low Temperature Physics, 2012, 167 : 435 - 441
  • [27] Development of Superconducting Multilayer Wiring for a 400-Pixel TES X-ray Microcalorimeter Array
    Ezoe, Yuichiro
    Oishi, Shihoko
    Yamada, Shinya
    Enokijima, Yosuke
    Iijima, Noriko
    Toba, Reina
    Ishisaki, Yoshitaka
    Ohashi, Takaya
    Mitsuda, Kazuhisa
    Morooka, Toshimitsu
    Tanaka, Keiichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [28] Design and Development of a 224-pixel TES X-Ray Microcalorimeter System for Microanalysis with STEM
    Hayashi, Tasuku
    Miyagawa, Rikuta
    Yagi, Yuta
    Tanaka, Keita
    Ota, Ryo
    Yamasaki, Noriko Y.
    Mitsuda, Kazuhisa
    Maehata, Keisuke
    Hara, Toru
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2024, 217 (3-4) : 341 - 349
  • [29] Development of Multilayer Readout Wiring for Large-Format TES X-Ray Microcalorimeter Arrays
    Ezoe, Yuichiro
    Ishisaki, Yoshitaka
    Oishi, Shihoko
    Abe, Yuki
    Ohashi, Takaya
    Yoshitake, Hiroshi
    Sekiya, Norio
    Mitsuda, Kazuhisa
    Morooka, Toshimitsu
    Tanaka, Keiichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 246 - 249
  • [30] Study of Multilayer X-ray Absorbers to Improve Detection Efficiency of TES X-ray Microcalorimeter Arrays
    Hayashi, T.
    Nagayoshi, K.
    Muramatsu, H.
    Yamasaki, N. Y.
    Mitsuda, K.
    Saito, M.
    Homma, T.
    Hara, T.
    Noda, H.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2016, 184 (1-2) : 257 - 262