Radiation dose reduction for chest CT with non-linear adaptive filters

被引:9
|
作者
Singh, Sarabjeet [1 ]
Digumarthy, Subba R. [1 ]
Back, Anni [2 ]
Shepard, Jo-anne O. [1 ]
Kalra, Mannudeep K. [1 ]
机构
[1] Massachusetts Gen Hosp Imaging, Boston, MA USA
[2] ContextVis AB, Linkoping, Sweden
关键词
CT radiation dose reduction; non-linear adaptive filters; postprocessing software; chest CT image quality; low dose chest CT; image noise reduction; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; ABDOMEN; ADULTS;
D O I
10.1258/ar.2012.120045
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT radiation dose reduction results in increased noise or graininess of images which affects the diagnostic information. One of the approaches to lower radiation exposure to patients is to reduce image noise with the use of image processing software in low radiation dose images. Purpose: To assess image quality and accuracy of non-linear adaptive filters (NLAF) at low dose chest CT. Material and Methods: In an IRB approved prospective study, 24 patients (mean age, 63 +/- 7.3 years; M: F ratio, 11: 13) gave informed consent for acquisition of four additional chest CT image series at 150, 110, 75, and 40 mAs (baseline image series) on a 64-slice MDCT over an identical 10-cm length. NLAF was used to process three low dose (110, 75, and 40 mAs) image series (postprocessed image series). Two radiologists reviewed baseline and postprocessed images in a blinded manner for image quality. Objective noise, CT attenuation values, patient weight, transverse diameters, CTDIvol, and DLP were recorded. Statistical analysis was performed using parametric and non-parametric tests for comparing postprocessed and baseline images. Results: No lesions were missed on baseline or postprocessed CT images (n = 80 lesions, 73 lesions <1 cm). At 40 mAs, subjective noise in mediastinal window settings were graded as unacceptable in baseline images and acceptable in postprocessed images. Visibility of smaller structures improved from suboptimal visibility in baseline images at 40 mAs to excellent in postprocessed images at 40 mAs. No major artifacts were seen due to NLAF postprocessing, except for minor beam hardening artifacts not affecting diagnostic decision-making (14/22) in both baseline and postprocessed image series. Diagnostic confidence for chest CT was improved to fully confident in postprocessed images at 40 mAs. Compared to baseline images, postprocessing reduced objective noise by 26% (14.2 +/- 4.7/19.2 +/- 6.4), 31.5% (15.2 +/- 4.7/22.2 +/- 5.7), and 41.5% (16.9 +/- 6/28.9 +/- 10.2) at 110 mAs, 75 mAs, and 40 mAs tube current-time product levels. Conclusion: Applications of NLAF can help reduce tube current down to 40 mAs for chest CT while maintaining lesion conspicuity and image quality.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [41] Radiation Dose Reduction for Pulmonary Nodule Follow-Up on Subsequent Chest CT
    Gallardo, L.
    Tien, H.
    Farah, M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [42] Emphysema quantification using chest CT: influence of radiation dose reduction and reconstruction technique
    den Harder A.M.
    de Boer E.
    Lagerweij S.J.
    Boomsma M.F.
    Schilham A.M.R.
    Willemink M.J.
    Milles J.
    Leiner T.
    Budde R.P.J.
    de Jong P.A.
    [J]. European Radiology Experimental, 2 (1)
  • [43] NON-LINEAR REDUCTION OF DATA
    EINBU, JM
    [J]. COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1983, 22 (02): : 260 - 267
  • [44] Lesion detection on reduced radiation dose CT images processed with noise reduction filters
    Kalra, MK
    Maher, MM
    Lucey, BC
    Blake, MA
    Karau, K
    Saini, S
    [J]. RADIOLOGY, 2002, 225 : 645 - 646
  • [45] CT radiation dose and radiation reduction strategies
    Park, Michael Yong
    Jung, Seung Eun
    [J]. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2011, 54 (12): : 1262 - 1268
  • [46] Non-linear Dynamic Modeling of Glucose in Type 1 Diabetes with Kernel Adaptive Filters
    Georga, Eleni I.
    Principe, Jose C.
    Polyzos, Demosthenes
    Fotiadis, Dimitrios I.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 5897 - 5900
  • [47] Multi-channel spline adaptive filters for non-linear active noise control
    Patel, Vinal
    George, Nithin, V
    [J]. APPLIED ACOUSTICS, 2020, 161
  • [48] Evaluating Popular Non-Linear Image Processing Filters for their Use in Regularized Iterative CT
    Xu, Wei
    Mueller, Klaus
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2864 - 2865
  • [49] ON OPTIMUM NON-LINEAR EXTRACTION AND CODING FILTERS
    BALAKRISHNAN, AV
    DRENICK, R
    [J]. IRE TRANSACTIONS ON INFORMATION THEORY, 1956, 2 (03): : 166 - 172
  • [50] Image restoration by multiresolution non-linear filters
    Hirata, R
    Brun, M
    Barrera, J
    Dougherty, ER
    [J]. NONLINEAR IMAGE PROCESSING AND PATTERN ANALYSIS XII, 2001, 4304 : 256 - 264