A calibration round-robin protocol for nanoindentation measurements of thin film coatings

被引:2
|
作者
Cabibbo, M. [1 ]
Spigarelli, S. [1 ]
机构
[1] Univ Politecn Marche, Dipartimento Ingn Ind & Sci Matemat DIISM, I-60131 Ancona, Italy
关键词
Nanoindentation; calibration; round-robin; thin films; coatings; Hardness; ELASTIC-MODULUS; MECHANICAL-PROPERTIES; INDENTATION; HARDNESS; LOAD;
D O I
10.1016/j.phpro.2012.12.001
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Nanoindentation has become a common technique for measuring hardness and elastic-plastic properties of materials, including coatings and thin films. In recent years, different nanoindenter instruments have been commercialized and used for this purpose. Every instrument is equipped with his own analysis software for the derivation of the hardness from the raw data. These data are mostly analyzed through the Oliver and Pharr method. In all cases, the calibration of compliance and area function are mandatory. The present work illustrates and describes a calibration procedure and an analysis approach of the raw data carried out in TiN and DLC coatings, for height different nanoindentation instruments, through several round robin experiments. Three different indenters were used: Berkovich, cube corner, spherical. It was clearly shown that the use of these common procedures consistently limited the hardness data spreading compared to same measurements performed using the instrument specific procedures. The following key recommendation for nanoindentation calibration must be followed: a) set a cut-off upper value for the penetration depth below which measurements must be considered unreliable, b) perform stiffness measurement specifically for each instrument/indenter couple, c) use a function, rather than a single value, for the stiffness, d) use a unique protocol and software of raw data analysis to limiting the data spread related to the instruments, and making the hardness data intercomparable. (c) 2013 The Authors. Published by Elsevier B.V. Selection and/or peer-review under responsibility of VINF
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Particle Filtering for Nonlinear Systems with Round-Robin Protocol and Uniform Quantization
    Shi, Miaomiao
    Niu, Yichun
    Sheng, Li
    Gao, Ming
    PROCEEDINGS OF THE 33RD CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2021), 2021, : 7144 - 7149
  • [32] FAULT ESTIMATION FOR TIME-VARYING SYSTEMS WITH ROUND-ROBIN PROTOCOL
    Fu, Haijing
    Dong, Hongli
    Song, Jinbo
    Hou, Nan
    Li, Gongfa
    KYBERNETIKA, 2020, 56 (01) : 107 - 126
  • [33] A Round-robin Test on Effectiveness of a VHF LISN for Radiated Emission Measurements
    Miyazaki, Chiharu
    Tanakajima, Katsuyuki
    Yamaguchi, Masanori
    Endo, Kiyoshi
    Muramatsu, Hidenori
    Kawano, Jiro
    2011 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2011, : 405 - 410
  • [34] Results of a "Round-Robin"-experiment on reflectivity measurements at a wavelength of 1.06 μm
    Nickel, D
    Fleig, C
    Erhard, A
    Letsch, A
    Giesen, A
    Jupé, M
    Starke, K
    Ristau, D
    Wilhelm, O
    Huber, RA
    Haspel, R
    Schuhmann, U
    Scharfenorth, C
    Eichler, HJ
    Gliech, S
    Duparré, A
    Schulz-Grosser, M
    Krasilnikova, A
    Haise, A
    Riede, W
    Balachninaite, O
    Grigonis, R
    Sirutkaitis, V
    Kazakevich, V
    LASER-INDUCED DAMAGE IN OPTICAL MATERIALS: 2002 AND 7TH INTERNATIONAL WORKSHOP ON LASER BEAM AND OPTICS CHARACTERIZATION, 2003, 4932 : 520 - 526
  • [35] A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols
    Drzymala, R. E.
    Alvarez, P. E.
    Bednarz, G.
    Bourland, J. D.
    DeWerd, L. A.
    Ma, L.
    Meltsner, S. G.
    Neyman, G.
    Novotny, J., Jr.
    Petti, P. L.
    Rivard, M. J.
    Shiu, A. S.
    Goetsch, S. J.
    MEDICAL PHYSICS, 2015, 42 (11) : 6745 - 6756
  • [36] Critical view of the results of the 2nd international round-robin test on EIS measurements of organic coatings
    Bakalli, Mirdash
    Keil, Patrick
    Strunz, Werner
    Broeker, Thomas
    Herrmann, Rainer
    Vogelsang, Joerg
    PROGRESS IN ORGANIC COATINGS, 2023, 180
  • [37] EUSTAS Protocol and Round-Robin testing of steviol glycosides by an internal standard method
    Geuns, Jan M. C.
    Struyf, Tom
    Bartholomees, Uria
    Ceunen, Stijn
    STEVIA: SIX MONTHS BEYOND AUTHORIZATION, 2012, : 117 - 142
  • [38] Asynchronous Control for Markov Switching Lur'e Systems With Round-Robin Protocol
    Luan, Le
    Mo, Wenxiong
    Wang, Hongbin
    Xu, Zhong
    Luo, Simin
    Cui, Yiping
    IEEE ACCESS, 2020, 8 (08) : 224668 - 224676
  • [39] Actuator and Sensor Attacks Against Multisensor State Estimation With Round-Robin Protocol
    Jin, Kaijing
    Ye, Dan
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2025,
  • [40] Optimal sensor attacks in cyber-physical systems with Round-Robin protocol
    Zhang, Xiao-Guang