Radiation Exposure During Continuous and Pulsed Fluoroscopy

被引:49
|
作者
Smith, Damien L. [1 ]
Heldt, Jonathan P. [1 ]
Richards, Gideon D. [1 ]
Agarwal, Gautum [1 ]
Brisbane, Wayne G. [1 ]
Chen, Catherine J. [1 ]
Chamberlin, Joshua D. [1 ]
Baldwin, D. Duane [1 ]
机构
[1] Loma Linda Univ, Dept Urol, Loma Linda, CA 92354 USA
关键词
DOSE REDUCTION; CARDIAC-CATHETERIZATION; IMAGE QUALITY;
D O I
10.1089/end.2012.0213
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and Purpose: Previous studies using pulsed fluoroscopy have shown variable effects on radiation exposure because of the ramp and trail effect in older C-arm systems. This study compares radiation delivered in pulsed and continuous modalities using a modern C-arm system. Materials and Methods: Thermoluminescent dosimeters (TLDs) positioned in three body locations directly measured radiation dose during simulated ureteroscopy. Thirty pedal activations were administered using a pulsed or continuous mode to visualize an implanted guidewire and a radiopaque stone. TLD absorbed radiation and image quality were compared between imaging modes. Results: Pulsed fluoroscopy delivered less radiation compared with continuous fluoroscopy at each site: Anterior skin (0.10 vs 0.26 mGy, P < 0.001), kidney (0.15 vs 0.40 mGy, P < 0.001), and posterior skin (0.92 vs 2.62 mGy, P < 0.001). Mean fluoroscopy time differed between continuous and pulsed modes (12.5 vs 3.0 seconds; P < 0.001). Fluoroscopy time positively correlated with radiation exposure at all sites: Anterior skin (0.017 mGy/s, R-2 = 0.90), left kidney (0.026 mGy/s, R-2 = 0.96), and posterior skin (0.18 mGy/sec, R-2 = 0.98). When evaluated by blinded urologists, 100% of reviewers felt pulsed images were adequate to identify guidewire position and 90.5% felt pulsed images were adequate for stone localization. Conclusion: Pulsed fluoroscopy reduced fluoroscopy time by 76% and radiation dose by 64% compared with continuous fluoroscopy. Pulsed fluoroscopy images were adequate for most tasks of ureteroscopy and should be considered for reduction of radiation during ureteroscopy.
引用
收藏
页码:384 / 388
页数:5
相关论文
共 50 条
  • [21] Tracking Intraoperative Fluoroscopy Utilization Reduces Radiation Exposure During Ureteroscopy
    Ngo, Tin C.
    Macleod, Liam C.
    Rosenstein, Daniel I.
    Reese, Jeffrey H.
    Shinghal, Rajesh
    JOURNAL OF ENDOUROLOGY, 2011, 25 (05) : 763 - 767
  • [22] TRACKING INTRAOPERATIVE FLUOROSCOPY UTILIZATION REDUCES RADIATION EXPOSURE DURING URETEROSCOPY
    Ngo, Tin
    Macleod, Liam
    Rosenstein, Daniel
    Reese, Jeffrey
    Shinghal, Rajesh
    JOURNAL OF UROLOGY, 2011, 185 (04): : E678 - E679
  • [23] RADIATION EXPOSURE DURING GASTROENTEROLOGIC FLUOROSCOPY - RISK ASSESSMENT FOR PREGNANT WORKERS
    KRUEGER, KJ
    HOFFMAN, BJ
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1992, 87 (04): : 429 - 431
  • [24] A multi-system comparison of entrance exposure rates from continuous and pulsed fluoroscopy systems
    Tkacik, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1373 - 1373
  • [25] Reduction of radiation exposure during catheter ablation for paroxysmal supraventricular tachycardia: The effect of a low frame rate of digital pulsed fluoroscopy
    Lee, Soo-Yong
    Kim, Jun
    Lee, Sang-Hyun
    Choi, Jin-Hee
    Kim, Jeong-Su
    Park, Yong-Hyun
    Kim, June-Hong
    Chun, Kook -Jin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (02) : 573 - 574
  • [26] Medical radiation exposure Exposure from fluoroscopy in theatre
    Duarte, Rui V.
    Raphael, Jon H.
    Hanu-Cernat, Dalvina
    BMJ-BRITISH MEDICAL JOURNAL, 2011, 342
  • [27] PATIENT EXPOSURE DURING FLUOROSCOPY
    MILLER, ER
    KAFAFIAN, J
    MADDISON, FE
    RADIOLOGY, 1963, 80 (03) : 477 - 485
  • [28] Radiation dose to the radiologist during continuous CT fluoroscopy-guided interventions
    Schulz, E
    Leibecke, T
    Melchert, UH
    Weiss, HD
    Stoeckelhuber, BM
    RADIOLOGY, 2002, 225 : 194 - 194
  • [29] SCATTER RADIATION DURING FLUOROSCOPY
    MORSE, D
    ANNALS OF THORACIC SURGERY, 1981, 32 (06): : 621 - 621
  • [30] Dynamics of the trapping of microparticles by an interference field on exposure to continuous and pulsed radiation
    Katarkevich V.M.
    Rubinov A.N.
    Éfendiev T.Sh.
    Journal of Applied Spectroscopy, 2004, 71 (1) : 115 - 121