Confocal multiple-transmitted-light interference microscope with increased lateral resolution

被引:0
|
作者
Qiu, Lirong [1 ]
Zhao, Weiqian [1 ]
机构
[1] Beijing Inst Technol, Beijing Key Lab Precis Optoelect Measurement Inst, Sch Optoelect, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
confocal microscopy; confocal interference; lateral resolution; resolution enhancement; SPATIAL-RESOLUTION; PROBE;
D O I
10.1117/1.OE.52.10.100504
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A plane-parallel plate of a specific thickness placed in front of the collecting lens in a confocal microscope (CM) is used to produce multiple-transmitted-light interference to sharpen the Airy main lobe so that the lateral resolution in the x-direction can be further improved. Numerical experiments show that the lateral full-width at half maximum in the x-direction has been narrowed down to 50 nm, and the lateral resolution has been improved by 80% in comparison with a conventional CM when thickness d = 5 mm, reflectivity R = 0.7, and NA = 0.65. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:3
相关论文
共 29 条
  • [21] Reliable Evaluation of the Lateral Resolution of a Confocal Raman Microscope by Using the Tungsten-dot Array Certified Reference Material
    Itoh, Nobuyasu
    Hanari, Nobuyasu
    ANALYTICAL SCIENCES, 2020, 36 (08) : 1009 - 1013
  • [22] Reliable Evaluation of the Lateral Resolution of a Confocal Raman Microscope by Using the Tungsten-dot Array Certified Reference Material
    Nobuyasu Itoh
    Nobuyasu Hanari
    Analytical Sciences, 2020, 36 : 1009 - 1013
  • [23] Demonstration of lateral resolution enhancement by focusing amplitude modulated radially polarized light in a confocal imaging system
    Meng, Peiwen
    Pham, Hong-Lien
    Pereira, Silvania F.
    Urbach, H. Paul
    JOURNAL OF OPTICS, 2020, 22 (04)
  • [24] Nondestructive measurement of an optical fiber refractive-index profile by a transmitted-light differential interference contact microscope
    Liu, ZY
    Dong, XM
    Chen, QH
    Yin, CY
    Xu, YX
    Zheng, YJ
    APPLIED OPTICS, 2004, 43 (07) : 1485 - 1492
  • [25] An All-Fiber-Optic Confocal Interference Microscope Using Low-Coherence Near-Infrared Light Source
    Kim, Do-Hyun
    Waynant, Ronald W.
    Ilev, Ilko K.
    Kang, Jin U.
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 1882 - +
  • [26] White-light interference microscopy: a way to obtain high lateral resolution over an extended range of heights
    Roy, Maitreyee
    Sheppard, Colin J. R.
    Cox, Guy
    Hariharan, Parameswaran
    OPTICS EXPRESS, 2006, 14 (15): : 6788 - 6793
  • [27] DEVELOPMENT OF A 500-A SPATIAL-RESOLUTION LIGHT-MICROSCOPE .1. LIGHT IS EFFICIENTLY TRANSMITTED THROUGH GAMMA-16 DIAMETER APERTURES
    LEWIS, A
    ISAACSON, M
    HAROOTUNIAN, A
    MURAY, A
    ULTRAMICROSCOPY, 1984, 13 (03) : 227 - 231
  • [28] A high-resolution MACROscope with differential phase contrast, transmitted light, confocal fluorescence, and hyperspectral capabilities for large-area tissue imaging
    Constantinou, P
    Nicklee, T
    Hedley, DW
    Damaskinos, S
    Wilson, BC
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2005, 11 (04) : 766 - 777
  • [29] Speckle-free quantitative phase and amplitude imaging using common-path lateral shearing interference microscope with pseudo-thermal light source illumination
    Tayal, Shilpa
    Usmani, Kashif
    Singh, Veena
    Dubey, Vishesh
    Mehta, Dalip Singh
    OPTIK, 2019, 180 : 991 - 996