Development and Application of Stereo Camera-Based Upper Extremity Workspace Evaluation in Patients with Neuromuscular Diseases

被引:30
|
作者
Kurillo, Gregorij [1 ]
Han, Jay J. [2 ]
Abresch, Richard T. [2 ]
Nicorici, Alina [2 ]
Yan, Posu [1 ]
Bajcsy, Ruzena [1 ]
机构
[1] Univ Calif Berkeley, Coll Engn, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Univ Calif Davis, Sch Med, Dept Phys Med & Rehabil, Sacramento, CA 95817 USA
来源
PLOS ONE | 2012年 / 7卷 / 09期
基金
美国国家科学基金会;
关键词
RELIABILITY; GONIOMETER; VALIDITY; MOTION; RANGE; LIMBS; MODEL;
D O I
10.1371/journal.pone.0045341
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The concept of reachable workspace is closely tied to upper limb joint range of motion and functional capability. Currently, no practical and cost-effective methods are available in clinical and research settings to provide arm-function evaluation using an individual's three-dimensional (3D) reachable workspace. A method to intuitively display and effectively analyze reachable workspace would not only complement traditional upper limb functional assessments, but also provide an innovative approach to quantify and monitor upper limb function. Methodology/Principal Findings: A simple stereo camera-based reachable workspace acquisition system combined with customized 3D workspace analysis algorithm was developed and compared against a sub-millimeter motion capture system. The stereo camera-based system was robust, with minimal loss of data points, and with the average hand trajectory error of about 40 mm, which resulted to similar to 5% error of the total arm distance. As a proof-of-concept, a pilot study was undertaken with healthy individuals (n = 20) and a select group of patients with various neuromuscular diseases and varying degrees of shoulder girdle weakness (n = 9). The workspace envelope surface areas generated from the 3D hand trajectory captured by the stereo camera were compared. Normalization of acquired reachable workspace surface areas to the surface area of the unit hemi-sphere allowed comparison between subjects. The healthy group's relative surface areas were 0.618 +/- 0.09 and 0.552 +/- 0.092 (right and left), while the surface areas for the individuals with neuromuscular diseases ranged from 0.03 and 0.09 (the most severely affected individual) to 0.62 and 0.50 (very mildly affected individual). Neuromuscular patients with severe arm weakness demonstrated movement largely limited to the ipsilateral lower quadrant of their reachable workspace. Conclusions/Significance: The findings indicate that the proposed stereo camera-based reachable workspace analysis system is capable of distinguishing individuals with varying degrees of proximal upper limb functional impairments.
引用
收藏
页数:10
相关论文
共 38 条
  • [21] Development of a Novel Web Camera-Based Contact-Free Major Depressive Disorder Screening System Using Autonomic Nervous Responses Induced by a Mental Task and Its Clinical Application
    Unursaikhan, Batbayar
    Tanaka, Nobuaki
    Sun, Guanghao
    Watanabe, Sadao
    Yoshii, Masako
    Funahashi, Kazuki
    Sekimoto, Fumihiro
    Hayashibara, Fumiaki
    Yoshizawa, Yutaka
    Choimaa, Lodoiravsal
    Matsui, Takemi
    [J]. FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [22] Development and evaluation of a novel music-based therapeutic device for upper extremity movement training: A pre-clinical, single-arm trial
    Schaffert, Nina
    Janzen, Thenille Braun
    Ploigt, Roy
    Schlueter, Sebastian
    Vuong, Veronica
    Thaut, Michael H.
    [J]. PLOS ONE, 2020, 15 (11):
  • [23] Development and first application testing of a new protocol for CT-based stability evaluation of the injured upper cervical spine
    Jung, Matthias K.
    Hoernig, Lukas
    Stuebs, Michael M. A.
    Gruetzner, Paul A.
    Kreinest, Michael
    [J]. EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (02) : 1389 - 1399
  • [24] Development and first application testing of a new protocol for CT-based stability evaluation of the injured upper cervical spine
    Matthias K. Jung
    Lukas Hörnig
    Michael M. A. Stübs
    Paul A. Grützner
    Michael Kreinest
    [J]. European Journal of Trauma and Emergency Surgery, 2022, 48 : 1389 - 1399
  • [25] Smartphone-based application for self-management of patients with colorectal cancer: development and usability evaluation
    Salmani, Hosna
    Nahvijou, Azin
    Sheikhtaheri, Abbas
    [J]. SUPPORTIVE CARE IN CANCER, 2022, 30 (04) : 3249 - 3258
  • [26] Smartphone-based application for self-management of patients with colorectal cancer: development and usability evaluation
    Hosna Salmani
    Azin Nahvijou
    Abbas Sheikhtaheri
    [J]. Supportive Care in Cancer, 2022, 30 : 3249 - 3258
  • [27] Development and Validation of an Artificial Intelligence-Based Motion Analysis System for Upper Extremity Rehabilitation Exercises in Patients with Spinal Cord Injury: A Randomized Controlled Trial
    Lee, Hyun Jong
    Jin, Seung Mo
    Kim, Seck Jin
    Kim, Jea Hak
    Kim, Hogene
    Bae, EunKyung
    Yoo, Sun Kook
    Kim, Jung Hwan
    [J]. HEALTHCARE, 2024, 12 (01)
  • [28] Leap Motion Controller Video Game-Based Therapy for Upper Extremity Motor Recovery in Patients with Central Nervous System Diseases. A Systematic Review with Meta-Analysis
    Cortes-Perez, Irene
    Zagalaz-Anula, Noelia
    Montoro-Cardenas, Desiree
    Lomas-Vega, Rafael
    Obrero-Gaitan, Esteban
    Catalina Osuna-Perez, Maria
    [J]. SENSORS, 2021, 21 (06) : 1 - 22
  • [29] Design, development, and usability evaluation of a smartphone-based application for nutrition management in patients with type II diabetes
    Ehsan Nabovati
    Fatemeh Rangraz Jeddi
    Seyed Mashallah Tabatabaeizadeh
    Rahele Hamidi
    Reihane Sharif
    [J]. Journal of Diabetes & Metabolic Disorders, 2023, 22 : 315 - 323
  • [30] Design, development, and usability evaluation of a smartphone-based application for nutrition management in patients with type II diabetes
    Nabovati, Ehsan
    Jeddi, Fatemeh Rangraz
    Tabatabaeizadeh, Seyed Mashallah
    Hamidi, Rahele
    Sharif, Reihane
    [J]. JOURNAL OF DIABETES AND METABOLIC DISORDERS, 2023, 22 (01) : 315 - 323