Development and Application of Stereo Camera-Based Upper Extremity Workspace Evaluation in Patients with Neuromuscular Diseases

被引:30
|
作者
Kurillo, Gregorij [1 ]
Han, Jay J. [2 ]
Abresch, Richard T. [2 ]
Nicorici, Alina [2 ]
Yan, Posu [1 ]
Bajcsy, Ruzena [1 ]
机构
[1] Univ Calif Berkeley, Coll Engn, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Univ Calif Davis, Sch Med, Dept Phys Med & Rehabil, Sacramento, CA 95817 USA
来源
PLOS ONE | 2012年 / 7卷 / 09期
基金
美国国家科学基金会;
关键词
RELIABILITY; GONIOMETER; VALIDITY; MOTION; RANGE; LIMBS; MODEL;
D O I
10.1371/journal.pone.0045341
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The concept of reachable workspace is closely tied to upper limb joint range of motion and functional capability. Currently, no practical and cost-effective methods are available in clinical and research settings to provide arm-function evaluation using an individual's three-dimensional (3D) reachable workspace. A method to intuitively display and effectively analyze reachable workspace would not only complement traditional upper limb functional assessments, but also provide an innovative approach to quantify and monitor upper limb function. Methodology/Principal Findings: A simple stereo camera-based reachable workspace acquisition system combined with customized 3D workspace analysis algorithm was developed and compared against a sub-millimeter motion capture system. The stereo camera-based system was robust, with minimal loss of data points, and with the average hand trajectory error of about 40 mm, which resulted to similar to 5% error of the total arm distance. As a proof-of-concept, a pilot study was undertaken with healthy individuals (n = 20) and a select group of patients with various neuromuscular diseases and varying degrees of shoulder girdle weakness (n = 9). The workspace envelope surface areas generated from the 3D hand trajectory captured by the stereo camera were compared. Normalization of acquired reachable workspace surface areas to the surface area of the unit hemi-sphere allowed comparison between subjects. The healthy group's relative surface areas were 0.618 +/- 0.09 and 0.552 +/- 0.092 (right and left), while the surface areas for the individuals with neuromuscular diseases ranged from 0.03 and 0.09 (the most severely affected individual) to 0.62 and 0.50 (very mildly affected individual). Neuromuscular patients with severe arm weakness demonstrated movement largely limited to the ipsilateral lower quadrant of their reachable workspace. Conclusions/Significance: The findings indicate that the proposed stereo camera-based reachable workspace analysis system is capable of distinguishing individuals with varying degrees of proximal upper limb functional impairments.
引用
收藏
页数:10
相关论文
共 38 条
  • [1] Evaluation of upper extremity reachable workspace using Kinect camera
    Kurillo, Gregorij
    Chen, Alic
    Bajcsy, Ruzena
    Han, Jay J.
    [J]. TECHNOLOGY AND HEALTH CARE, 2013, 21 (06) : 641 - 656
  • [2] Correlates of different upper extremity functional capacity evaluation methods in neuromuscular diseases
    Kilinc, Muhammed
    Atay, Sibel
    Oeksuez, Cigdem
    Aksu, Sibel
    Tan, Yildirim Ersin
    Kayihan, Huelya
    [J]. NEUROMUSCULAR DISORDERS, 2006, 16 : S170 - S170
  • [3] Relationship between respiratory functions and upper extremity functions in patients with neuromuscular diseases
    Safran, Ertugrul
    Yildiz, Aysel
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [4] Clinical validation of automated depth camera-based measurement of the Fugl-Meyer assessment for upper extremity
    Wang, Zhaoyang
    Zhang, Tao
    Fan, Jingyuan
    Gu, Fanbin
    Yu, Qiuhua
    Wang, Honggang
    Yang, Jiantao
    Zhu, Qingtang
    [J]. CLINICAL REHABILITATION, 2024, 38 (08) : 1091 - 1100
  • [5] Is proprioceptive neuromuscular facilitation treatment effective in increasing the upper extremity muscle strength and activities of daily living in patients with neuromuscular diseases?
    Aksu, S.
    Kilinc, M.
    Atay, S.
    Iyigun, G.
    Tan, E.
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2008, 15 : 377 - 377
  • [6] LiDAR-based benchmark approach development and validation for unloading-on-the-go systems incorporating stereo camera-based perception
    Jiang, Chufan
    Liu, Ziping
    Evans, John T.
    Shaver, Gregory M.
    Heusinger, Logan J.
    Puryk, Corwin M.
    [J]. BIOSYSTEMS ENGINEERING, 2023, 234 : 13 - 31
  • [7] Smartphone camera-based micron-scale displacement measurement: development and application in soft actuators
    Najathulla, Bhagavathi Chalil
    Deshpande, Atul Suresh
    Khandelwal, Mudrika
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2022, 50 (06) : 616 - 625
  • [8] Application development of camera-based driver assistance systems on a programmable multi-processor architecture
    Techmer, Axel
    [J]. 2007 IEEE INTELLIGENT VEHICLES SYMPOSIUM, VOLS 1-3, 2007, : 595 - 600
  • [9] Usefulness of Kinect sensor–based reachable workspace system for assessing upper extremity dysfunction in breast cancer patients
    Kyeong Eun Uhm
    Seunghwan Lee
    Gregorij Kurillo
    Jay J. Han
    Jung-Hyun Yang
    Young Bum Yoo
    Jongmin Lee
    [J]. Supportive Care in Cancer, 2020, 28 : 779 - 786
  • [10] Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients
    Annie K. Kogler
    Andrew M. Polemi
    Surabhi Nair
    Stanislaw Majewski
    Lynn T. Dengel
    Craig L. Slingluff
    Brian Kross
    S. J. Lee
    J. E. McKisson
    John McKisson
    Andrew G. Weisenberger
    Benjamin L. Welch
    Thomas Wendler
    Philipp Matthies
    Joerg Traub
    Michael Witt
    Mark B. Williams
    [J]. EJNMMI Research, 10