Impact of cement-augmented condylar screws in locking plate osteosynthesis for distal femoral fractures - A biomechanical analysis

被引:14
|
作者
Bliemel, Christopher [1 ]
Oberkircher, Ludwig [1 ]
Bockmann, Benjamin [1 ]
Petzold, Eric [1 ]
Aigner, Rene [1 ]
Heyse, Thomas Jan [1 ]
Ruchholtz, Steffen [1 ]
Buecking, Benjamin [1 ]
机构
[1] Univ Hosp Giessen & Marburg, Ctr Orthopaed & Trauma Surg, Baldingerstr, D-35043 Marburg, Germany
关键词
Distal femoral fracture; Polyaxial angular stable plate osteosynthesis; Cement augmentation; Osteoporosis; Biomechanical analysis; INVASIVE STABILIZATION SYSTEM; FEMUR FRACTURES; IMPLANT AUGMENTATION; INTERNAL-FIXATION; BLADE PLATE; BONE; TRIAL; NAIL;
D O I
10.1016/j.injury.2016.10.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Compromised bone quality and the need for early mobilization continue to lead to implant failure in elderly patients with distal femoral fractures. The cement augmentation of screws might facilitate improving implant anchorage. The aim of this study was to analyse the impact of cement augmentation of the condylar screws on implant fixation in a human cadaveric bone model. Material and methods: Ten pairs of osteoporotic femora (mean age: 90 years, range: 84-99 years) were used. A 2-cm gap osteotomy was created in the metaphyseal region to simulate an unstable AO/OTA 33-A3 fracture. All specimens were treated with a polyaxial locking plate. Specimens randomly assigned to the augmented group received an additional cement augmentation of the condylar screws using bone cement. A servohydraulic testing machine was used to perform incremental cyclic axial loading using a load-to-failure mode. Results: All specimens survived at least 800 N of axial compressive force. The mean compressive forces leading to failure were 1620 N (95% CI: 1382-1858 N) in the non-augmented group and 2420 N (95% CI: 2054-2786 N) in the group with cement-augmented condylar screws (p = 0.005). Deformation with cutting out of the condylar screws and condylar fracture were the most common reasons for failure in both groups. Whereas axial stiffness was comparable between both osteosyntheses (p = 0.508), significant differences were observed for the plastic deformation of the constructs (p = 0.014). Conclusion: The results of the present study showed that the cement augmentation of the condylar screws might be a promising technique for the fixation of distal femoral fractures in elderly patients with osteoporotic bones. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2688 / 2693
页数:6
相关论文
共 50 条
  • [41] Biomechanical Comparison of Osteoporotic Distal Radius Fractures Fixed by Distal Locking Screws with Different Length
    Liu, Xiong
    Wu, Wei-dong
    Fang, Ya-feng
    Zhang, Mei-chao
    Huang, Wen-hua
    PLOS ONE, 2014, 9 (07):
  • [42] Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
    Onder, Yilmaz
    Bulut, Tugrul
    Eroglu, Osman Nuri
    Ciklacandir, Samet
    Isler, Yalcin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (06)
  • [43] Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures
    Kim, Joon-Woo
    Oh, Chang-Wug
    Oh, Jong-Keon
    Park, Il-Hyung
    Kyung, Hee-Soo
    Park, Kyeong-Hyeon
    Yoon, Seong-Dae
    Kim, Seong-Min
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (03): : 751 - 757
  • [44] Cement augmentation of an angular stable plate osteosynthesis for supracondylar femoral fractures - biomechanical investigation of a new fixation device
    Martin Bäumlein
    Antonio Klasan
    Christine Klötzer
    Benjamin Bockmann
    Daphne Eschbach
    Matthias Knobe
    Benjamin Bücking
    Steffen Ruchholtz
    Christopher Bliemel
    BMC Musculoskeletal Disorders, 21
  • [45] Percutaneous Cement-Augmented Screws Short Fixation for the Treatment of Severe Osteoporotic Vertebra Burst Fractures
    Fiore, Giorgio
    Tariciotti, Leonardo
    Borsa, Stefano
    Nicoli, Daniele
    Schisano, Luigi
    Bertani, Giulio Andrea
    Locatelli, Marco
    Pluderi, Mauro
    WORLD NEUROSURGERY, 2022, 163 : E522 - E531
  • [46] A new guide for condylar blade-plate on distal femoral fractures
    Çullu, E
    Özkan, I
    Baltaci, E
    Alparslan, E
    ORTHOPEDICS, 2005, 28 (05) : 447 - 449
  • [47] Management of distal femoral periprosthetic fractures by distal femoral locking plate: A retrospective study.
    Thukral, Rajiv
    Marya, S. K. S.
    Singh, Chandeep
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 199 - 207
  • [48] Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures
    Gogna Paritosh
    Mukhopadhyay Reetadyuti
    Singh Amanpreet
    Devgan Ashish
    Arora Sahil
    Batra Amit
    Yadav Sushil Kumar
    中华创伤杂志英文版, 2015, 18 (05) : 279 - 283
  • [49] Application of distal femoral 90° locking plate in children with supracondylar femoral fractures
    Zhang, Y. -J.
    Wang, Y. -J.
    Wang, S. -H.
    Song, X. -L.
    Zhao, N.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (17) : 7956 - 7967
  • [50] Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures
    Gogna, Paritosh
    Mukhopadhyay, Reetadyuti
    Singh, Amanpreet
    Devgan, Ashish
    Arora, Sahil
    Batra, Amit
    Yadav, Sushil Kumar
    CHINESE JOURNAL OF TRAUMATOLOGY, 2015, 18 (05) : 279 - 283