Research on Electromagnetic Radiated Disturbance of Pantograph Arc in High-speed Railway

被引:0
|
作者
Ma, Lan [1 ]
Wen, Yinghong [1 ]
Zhou, Kesheng [1 ]
Zhang, Jinbao [1 ]
Zhang, Dan [1 ]
Shan, Qin [2 ]
机构
[1] Beijing Jiaotong Univ, EMC Lab, Sch Elect & Informat Engn, Beijing, Peoples R China
[2] China Acad Elect & Informat Technol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
pantograph arc; radiated disturbance; electric field; TRACTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pantograph arc is one of the electromagnetic compatibility problems to affect the safety of the high speed railway and has become the key factors needed to be solved urgently. Based on the measured electromagnetic radiated disturbance of pantograph arc in field test, this paper analyzes the principle of pantograph arc and the arc signal in time domain and frequency domain respectively. According to the measured arc signal in time domain, the research sets up a pantograph arc space radiation model to simulate the radiated disturbance in railway. The high frequency radiated field outside the car decays faster than the low frequency along the distance from the pantograph. The disturbances of arc in all positions inside the car are almost the same intensity and have no relationship with the pantograph position. This could be certain reference to place the equipment and system inside and outside the car.
引用
收藏
页码:637 / 641
页数:5
相关论文
共 50 条
  • [21] Experimental Research on Radiated Electroma gnetic Noise of Pantograph Arc
    Wang, Zhiyong
    Guo, Fengyi
    Wang, Xili
    Zhang, Yanli
    Wang, Baowei
    Yan, Xiaoming
    PROCEEDINGS OF THE 2015 SIXTY-FIRST IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS (HOLM), 2015, : 256 - 261
  • [22] Research on the Arc Image Recognition Based on the Pantograph Videos of High-Speed Electric Multiple Unit (EMU)
    Yu, Liangliang
    Huang, Shize
    Zhang, Fan
    Li, Guanhua
    INTERNATIONAL SYMPOSIUM FOR INTELLIGENT TRANSPORTATION AND SMART CITY (ITASC) 2017 PROCEEDINGS, 2017, 62 : 290 - 301
  • [23] Optimization of high-speed railway pantographs for improving pantograph-catenary contact
    Jorge Ambrósio
    Joo Pombo
    Manuel Pereira
    Theoretical & Applied Mechanics Letters, 2013, 3 (01) : 51 - 57
  • [24] Application of SMA Composites in the Collectors of the Railway Pantograph for the Italian High-Speed Train
    Tuissi, A.
    Bassani, P.
    Casati, R.
    Bocciolone, M.
    Collina, A.
    Carnevale, M.
    Lo Conte, A.
    Previtali, B.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2009, 18 (5-6) : 612 - 619
  • [25] The Development of Pantograph-catenary Dynamics Testing Rig for High-speed Railway
    Wei Wei
    Yang Zhidong
    Gao Ting
    PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC), 2013, : 3535 - 3539
  • [26] Servo actuated railway pantograph for high-speed running with constant contact force
    Galeotti, G.
    Galanti, M.
    Magrini, S.
    Toni, P.
    Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit, 1993, 207 (01) : 37 - 49
  • [27] Research on the Development Laws of Articulated Phase Insulator Arc Movement in High-speed Railway
    Han Z.
    Chen C.
    Shen R.
    Liu S.
    Gao S.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (10): : 3154 - 3162
  • [28] Effect of Pantograph's Main Structure on the Contact Quality in High-Speed Railway
    Wang, Jiangwen
    Mei, Guiming
    SHOCK AND VIBRATION, 2021, 2021
  • [29] Optimal Control of Pantograph for High-Speed Railway Considering Actuator Time Delay
    Xie S.
    Zhang J.
    Song B.
    Liu Z.
    Gao S.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (02): : 505 - 514
  • [30] Experimental study of electromagnetic radiation characteristics of pantograph-catenary off-line arcs in high-speed railway
    Jin M.
    Liu S.
    Xing T.
    Yang C.
    Liu W.
    Fang Q.
    Hu M.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (12): : 177 - 183