Development and application of a dispersive solid-phase extraction method for the simultaneous determination of chloroacetamide herbicide residues in soil by gas chromatography-tandem mass spectrometry (GC-MS/MS)

被引:12
|
作者
Yang, Juan [1 ,2 ]
Li, Qiwan [1 ,2 ]
Wang, Luxiang [1 ,2 ]
Shao, Jinliang [1 ,2 ]
Mei, Wenquan [1 ,2 ]
Wang, Li [1 ,2 ]
机构
[1] Yunnan Acad Agr Sci, Inst Qual Standard & Testing Technol, Kunming, Yunnan, Peoples R China
[2] Minist Agr, Ctr Inspect & Testing Qual & Safety Agr Prod, Kunming, Yunnan, Peoples R China
关键词
Soil; chloroacetamide herbicides; gas chromatography; triple quadrupole mass spectrometry; dispersive solid-phase extraction (DSPE); PRESSURIZED LIQUID EXTRACTION; SOLVENT-EXTRACTION; METABOLITES; WATER; PESTICIDES; QUECHERS; ACETOCHLOR; MS; DEGRADATION; METOLACHLOR;
D O I
10.1080/03067319.2019.1593398
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a convenient and sensitive analytical method based on dispersive solid-phase extraction (dSPE) and gas chromatography-tandem mass spectrometry in tandem was developed for the simultaneous determination of six chloroacetamide herbicides (acetochlor, alachlor, metolachlor, metazachlor, butachlor and pretilachlor) in soil. Parameters that could influence the extraction efficiency such as the varieties of solvents, the amount of solvents and sorbents were investigated. The optimized extractions were performed by mixing 5.0 g of dried soil with 10.0 mL acetonitrile, 10.0 mL deionized water and 4.0 g sodium chloride, and then the extract was purified with 50.0 mg N-propyl ethylenediamine (PSA), 50.0 mg C18, 10.0 mg graphitized carbon black (GCB) and 100.0 mg MgSO4 (5:5:1:10). At 5.0, 25.0 and 100.0 ng g(-1) fortification levels for each analyte, the average obtained recoveries ranged from 87.7% to 108.0% with relative standard deviation (RSD) between 3.8% and 10.9%. The soil matrix effect of the six compounds were lower than 11.0%. The linear relation was observed in the range of 5.0-500.0 ng g(-1) and the correlation coefficient (R-2) of these compounds were higher than 0.998. The detection limits (LODs) were in the range of 0.2-1.0 ng g(-1), and the limits of quantification (LOQs) were between 0.8 and 2.2 ng g(-1). Comparing with the gas chromatography-electron capture detector (GC-ECD), the GC-tandem mass spectrometry (MS/MS) method can improve the anti-interference ability and thus get better separation of the chloroacetamide herbicides. Additionally, this method was verified to fit for soil samples with broad organic matter range (16.2 to 83.0 g kg(-1)). The developed method was successfully applied for analysing 26 field soil samples collected from Dianchi lake basin in the southeast of China. About 42.0% soil samples were detected with these herbicides, of which butachlor was the most frequently detected and the highest concentration was up to 137.0 ng g(-1) in rape soil.
引用
收藏
页码:282 / 296
页数:15
相关论文
共 50 条
  • [41] Application of gas chromatography-tandem mass spectrometry (GC-MS-MS) with pulsed splitless injection for the determination of multiclass pesticides in vegetables
    Tong, L
    Ma, XD
    Li, CJ
    ANALYTICAL LETTERS, 2006, 39 (05) : 985 - 996
  • [42] Optimization of Solid Phase Extraction (SPE) for the determination of Synthetic Musks in water by Gas Chromatography-Mass Spectrometry (GC-MS)
    Sang, Wen-jing
    Zhou, Xue-fei
    Zhang, Ya-lei
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 6085 - 6088
  • [43] Simultaneous determination of 11 quinolones in hotpot ingredients by dispersive solid-phase extraction and ultra performance liquid chromatography-tandem mass spectrometry
    Cao Peng
    Mou Yan
    Gao Fei
    Geng Jinpei
    Zhang Xiqing
    Sui Tao
    Liang Junni
    Sha Meilan
    Guan Lili
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (09) : 862 - 868
  • [44] Gas-Chromatography - Tandem Mass Spectrometry (GC-MS) method for the determination of glycerol in human urine samples
    Dobrescu, Manuela
    Zorio, Mirela
    Ionica, Mihai
    ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES IX, 2018, 10977
  • [45] Determination of Preservative Allergens in Skincare Products by Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS) With Response Surface Methodology (RSM) Optimization
    Liu, Tongtong
    Han, Weina
    Wang, Lulu
    Hou, Xiaoyu
    Cao, Jin
    ANALYTICAL LETTERS, 2025, 58 (03) : 454 - 464
  • [46] Determination of Four Flavorings in Infant Formula by Solid-Phase Extraction and Gas Chromatography-Tandem Mass Spectrometry
    Shen, Yan
    Hu, Beizhen
    Chen, Xiangzhun
    Miao, Qian
    Wang, Chengjun
    Zhu, Zhenou
    Han, Chao
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (45) : 10881 - 10888
  • [47] Application of solid-phase microextraction for the determination of pyrethroid residues in vegetable samples by GC-MS
    J. Beltran
    A. Peruga
    E. Pitarch
    F. J. López
    F. Hernández
    Analytical and Bioanalytical Chemistry, 2003, 376 : 502 - 511
  • [48] Application of solid-phase microextraction for the determination of pyrethroid residues in vegetable samples by GC-MS
    Beltran, J
    Peruga, A
    Pitarch, E
    López, FJ
    Hernández, F
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) : 502 - 511
  • [49] Determination of 19 Acidic Pesticide Residues in Fruit by Dispersive Solid Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry
    Jin Fen
    Shi Xiao-Mei
    Yu Zhi-Yong
    Li Min-Jie
    Shao Hua
    Jin Mao-Jun
    Wang Jing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (03) : 354 - 359
  • [50] Determination of 16 Polycyclic Aromatic Hydrocarbons in Tea by Simultaneous Dispersive Solid-Phase Extraction and Liquid-Liquid Extraction Coupled with gas Chromatography-Tandem Mass Spectrometry
    Chen, Hongping
    Gao, Guanwei
    Liu, Pingxiang
    Pan, Rong
    Liu, Xin
    Lu, Chengyin
    FOOD ANALYTICAL METHODS, 2016, 9 (08) : 2374 - 2384