Evaluation of the Durability of PE-HD Geosynthetic Barriers Using High-Pressure Autoclave Tests

被引:1
|
作者
Zanzinger, Helmut [1 ]
机构
[1] German Plast Ctr, SKZ, Friedrich Bergius Ring 22, D-97076 Wurzburg, Germany
关键词
Durability; High density polyethylene polymeric geosynthetic barrier; High-pressure autoclave test; Oxidation; Service life; LIFETIME;
D O I
10.1007/s40891-020-00221-2
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
To evaluate the resistance of a 2 mm thick polymeric geosynthetic barrier (GBR-P) made of high-density polyethylene (PE-HD), oxidation tests at 80 degrees C using high-pressure autoclaves at three different oxygen pressures were carried out. After different times, 18 different evaluations were performed on the aged test specimens of the GBR-P. The following characteristics were considered: thermoanalytical methods like oxidation induction time (OIT), crystallinity and oxidation onset temperature (OOT), viscosity measurements like melt mass-flow rate (MFR) and viscosity, mechanical properties of the short term tensile test as well as stress crack resistance methods with the notched constant tensile load (NCTL) test and the strain hardening test (SHT). The failure times extrapolated to atmospheric conditions at the test temperature of 80 degrees C were in the range of 450-550 days for the stress crack tests. For the analytical methods, the failure times were 620-780 days and for the tests in the short-time tensile test, the failure times were between 700 and 900 days, depending on the property. To evaluate the OIT measurements, investigations were carried out on the influence of the sampling, preparation and treatment of the OIT measurement samples. Furthermore, the influence of oxidation on the thickness of the test samples was investigated. For this purpose, test specimens with thicknesses of 1 mm, 2 mm, 4 mm and 10 mm were produced and tested with the same material. The consumption of antioxidants on the surface of the test specimens was twice as high as inside the specimens. It was shown that a wide range of parameters is suitable for representing the ageing states of a PE-HD GBR-P. With very few exceptions, it was possible to determine the time transitions up to which the properties hardly changed and from which a steep rise or steep fall occurred. The most reliable and practicable test methods for ageing tests in the study were: elongation at break in the tensile test, the strain hardening modulus, OIT and OOT.
引用
收藏
页数:23
相关论文
共 49 条
  • [31] DEVELOPMENT OF SCREENING TECHNOLOGY FOR HYDROGEN EMBRITTLEMENT COMPATIBILITY OF PIPELINE STEELS AND WELDS USING SIMPLE IN-SITU TESTS IN HIGH-PRESSURE ENVIRONMENTS
    Shin, Hyung-Seop
    Min, Eunsu
    Kang, Sungbeom
    Baek, Un-Bong
    PROCEEDINGS OF ASME 2022 PRESSURE VESSELS AND PIPING CONFERENCE, PVP2022, VOL 4B, 2022,
  • [32] CRITICAL-EVALUATION OF METHANE HYDROCARBON HIGH-PRESSURE EXPERIMENTAL VAPOR LIQUID EQUILIBRIUM DATA USING EQUATIONS OF STATE
    LEGRET, D
    RICHON, D
    RENON, H
    FLUID PHASE EQUILIBRIA, 1984, 17 (03) : 323 - 350
  • [33] RE-EVALUATION OF VANCOMYCIN PHARMACOKINETICS IN PREMATURE-INFANTS USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY (HPLC)
    NAQVI, SH
    REICHLEY, RM
    KEENAN, WJ
    FORTUNE, KP
    CLINICAL RESEARCH, 1984, 32 (04): : A804 - A804
  • [34] Evaluation of the aluminum migration from metallic seals to coffee beverage after using a high-pressure coffee pod machine
    Iscuissati, Isabelle Pereira
    Galazzi, Rodrigo Moretto
    Miro, Manuel
    Arruda, Marco Aurelio Zezzi
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 104
  • [35] EVALUATION OF A NORTH-SEA-OIL FOR RECOVERY BY IN-SITU COMBUSTION USING HIGH-PRESSURE DIFFERENTIAL SCANNING CALORIMETRY
    LUKYAA, ABA
    HUGHES, R
    MILLINGTON, A
    PRICE, D
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1994, 72 (A2): : 163 - 168
  • [36] Evaluation of putative differences in vessel density and flow area in normal tension and high-pressure glaucoma using OCT-angiography
    Martucci, Alessio
    Giannini, Clarissa
    Di Marino, Matteo
    Sorge, Roberto Pietro
    Aiello, Francesco
    Scuteri, Damiana
    Mancino, Raffaele
    Nucci, Carlo
    Cesareo, Massimo
    GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE RETINA AND BEYOND - PT B, 2020, 257 : 85 - 98
  • [37] Preparation, Characterization, and Safety Evaluation of a Submicron Emulsion Processed Using High-Pressure Homogenization to Protect Bitter Melon Seed Oil
    Wang, Huiling
    Guo, Heng
    Shuai, Xiaoyan
    Ma, Yan
    Zhang, Rui
    Wu, Muci
    He, Jingren
    Ling, Jiayan
    FOODS, 2025, 14 (05)
  • [38] EVALUATION OF THE GROWTH HORMONE-BINDING PROTEINS IN HUMAN PLASMA USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY GEL-FILTRATION
    TAR, A
    HOCQUETTE, JF
    SOUBERBIELLE, JC
    CLOT, JP
    BRAUNER, R
    POSTELVINAY, MC
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1990, 71 (05): : 1202 - 1207
  • [39] EVALUATION OF HYDROGEN EMBRITTLEM ENT BEHAVIORS IN PIPELINE STEEL WELDS USING IN-SITU SP TEST IN HIGH-PRESSURE HYDROGEN ENVIRONMENTS
    Shin, Hyung-Seop
    Custodio, N. A.
    Yeo, Juho
    Cho, Jae-Won
    Baek, Un-Bong
    Nahm, Seung-Hoon
    PROCEEDINGS OF ASME 2021 PRESSURE VESSELS AND PIPING CONFERENCE (PVP2021), VOL 4, 2021,
  • [40] EVALUATION OF SOUND-VELOCITY AND DENSITY OF LUBRICANTS UNDER HIGH-PRESSURE BY BRILLOUIN-SCATTERING USING DIAMOND-ANVIL CELL
    NAKAMURA, Y
    FUJISHIRO, I
    TAMURA, T
    JSME INTERNATIONAL JOURNAL SERIES C-DYNAMICS CONTROL ROBOTICS DESIGN AND MANUFACTURING, 1995, 38 (01): : 122 - 127