Wavelet-based event detection in implantable cardiac rhythm management devices

被引:12
|
作者
Åström, M
Olmos, S
Sörnmo, L
机构
[1] Lund Univ, Dept Elect Engn, SE-22100 Lund, Sweden
[2] Univ Zaragoza, Dept Elect Engn & Commun, Zaragoza 50009, Spain
关键词
electrogram; event detection; implantable cardiac devices; pacemakers; wavelets;
D O I
10.1109/TBME.2005.869775
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a novel event detector for implantable devices. The algorithm is based on a signal model which describes an event as a linear combination of basis functions. The linear combination involves two fundamental electrogram waveforms represented at different time scales. An efficient, low-complexity detector is developed using the dyadic wavelet transform with integer filter coefficients, and a generalized likelihood ratio test. The results show that reliable detection is obtained at an intermediate signal-to-noise ratio (SNR = 25 dB) for various common noise sources. In terms of probabilities of missed events and false alarms, an over-all performance of 0.7% and 0.1%, respectively, was achieved on electrograms corrupted by the different noise types at an intermediate SNR.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [1] Detection of atrial arrhythmia for cardiac rhythm management by implantable devices
    Morris, MM
    KenKnight, BH
    Lang, DJ
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 : 133 - 139
  • [2] Two Implantable Devices for Cardiac Rhythm Management
    Tang, Jonathan E.
    Ryu, Jasmine N.
    Essandoh, Michael K.
    Savona, Salvatore J.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (02) : 326 - 329
  • [3] Future of Implantable Devices for Cardiac Rhythm Management
    Lau, Chu-Pak
    Siu, Chung-Wah
    Tse, Hung-Fat
    CIRCULATION, 2014, 129 (07) : 811 - 822
  • [4] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (04): : 475 - 486
  • [5] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    BILITCH, M
    HAUSER, RG
    GOLDMAN, BS
    MALONEY, JD
    HARTHORNE, JW
    FURMAN, S
    PARSONNET, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 389 - 398
  • [6] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    FURMAN, S
    GROSS, J
    FRAME, R
    JOHNSTON, D
    PARSONNET, V
    ROTHBART, ST
    ZIMMERMAN, J
    KAWANISHI, DT
    SONG, SL
    HASHIMOTO, KK
    BUCKINGHAM, TA
    GOLDIN, MD
    DENKER, ST
    LIPTON, IH
    CASTLE, LW
    SHEWCHIK, JM
    HARTHORNE, JW
    RUSKIN, JN
    GARAN, H
    MCGOVERN, BA
    GRIFFIN, JC
    SCHEINMAN, MM
    LESH, MD
    DORIAN, P
    NEWMAN, D
    DENES, P
    DAHL, W
    SAKSENA, S
    KROL, RB
    FOGOROS, RN
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (01): : 131 - 133
  • [7] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (10): : 1559 - 1561
  • [8] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (04): : 589 - 602
  • [9] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (01): : 120 - 121
  • [10] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    BILITCH, M
    DENES, P
    GOLDMAN, BS
    MALONEY, JD
    HARTHORNE, JW
    GRIFFIN, JC
    FURMAN, S
    PARSONNET, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (03): : 371 - 380