Microfluidic electrophoresis chip coupled to microdialysis for in vivo monitoring of amino acid neurotransmitters

被引:88
|
作者
Sandlin, ZD
Shou, MS
Shackman, JG
Kennedy, RT [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac051044z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microfluidic electrophoresis devices were coupled on-fine to microdialysis for in vivo monitoring of primary amine neurotransmitters in rat brain. The devices contained a sample introduction channel for dialysate, a precolumn reactor for derivatization with o-phthaldialdehyde, a flow-gated injector, and a separation channel. Detection was performed using confocal laser-induced fluorescence. In vitro testing revealed that the initial device design had detection limits for amino acids of similar to 200 nM, relative standard deviation of peak heights of 2%, and separations within 95 s with up to 30 200 theoretical plates when applying an electric field of 370 V/cm. A second device design that allowed electric fields of 1320 V/cm to be applied while preserving the reaction time allowed separations within 20 s with up to 156 000 theoretical plates. Flow splitting into the electrokinetic network from hydrodynamic flow in the sample introduction channel was made negligible for sampling flow rates from 0.3 to 1.2 mu L/min by placing a 360-mu m-diameter fluidic access hole that had flow resistance (0.15-7.2) x 10(8)-fold lower than that of the electrokinetic network at the junction of the sample introduction channel and the electrokinetic network. Using serial injections, the device allowed the dialysate stream to be analyzed at 130-s intervals. In vivo monitoring was demonstrated by using the microdialysis/microfluidic device to record glutamate concentrations in the striatum of an anesthetized rat during infusion of the glutamate uptake inhibitor L-trans-pyrrolidine-2,4-dicarboxylic acid. These results prove the feasibility of using a microfabricated fluidic system coupled to sampling probes for chemical monitoring of complex media such as mammalian brain.
引用
收藏
页码:7702 / 7708
页数:7
相关论文
共 50 条
  • [11] In vivo monitoring of the monoamine neurotransmitters in the rat brain by microdialysis coupled with the liquid chromatography dual electrochemical detector
    Lu, JX
    Zhang, S
    Wang, AB
    Zhang, W
    Jin, LT
    TALANTA, 2000, 52 (05) : 807 - 815
  • [12] In Vivo Monitoring of Amino Acid Biomarkers from Inguinal Adipose Tissue Using Online Microdialysis-Capillary Electrophoresis
    Weisenberger, Megan M.
    Bowser, Michael T.
    ANALYTICAL CHEMISTRY, 2017, 89 (01) : 1009 - 1014
  • [13] Analysis of amino acid neurotransmitters in hypothalamus of rats during cerebral ischemia-reperfusion by microdialysis and capillary electrophoresis
    Li, Hua
    Yan, Zhi-ying
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (11) : 1185 - 1192
  • [14] In vivo monitoring of cerebral agmatine by microdialysis and capillary electrophoresis
    Betancourt, Luis
    Rada, Pedro
    Paredes, Daniel
    Hernandez, Luis
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 880 : 58 - 65
  • [15] MONITORING EXCITATORY AMINO-ACID RELEASE INVIVO BY MICRODIALYSIS WITH CAPILLARY ELECTROPHORESIS ELECTROCHEMISTRY
    OSHEA, TJ
    WEBER, PL
    BAMMEL, BP
    LUNTE, CE
    LUNTE, SM
    SMYTH, MR
    JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 189 - 195
  • [16] Capillary electrophoresis combined with microdialysis in the human spinal cord: A new tool for monitoring rapid peroperative changes in amino acid neurotransmitters within the dorsal horn
    Parrot, S
    Sauvinet, V
    Xavier, JM
    Chavagnac, D
    Mouly-Badina, L
    Garcia-Larrea, L
    Mertens, P
    Renaud, B
    ELECTROPHORESIS, 2004, 25 (10-11) : 1511 - 1517
  • [17] A review of microdialysis coupled to microchip electrophoresis for monitoring biological events
    Saylor, Rachel A.
    Lunte, Susan M.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1382 : 48 - 64
  • [18] Microfluidic Chip for High Efficiency Electrophoretic Analysis of Segmented Flow from a Microdialysis Probe and in Vivo Chemical Monitoring
    Wang, Meng
    Roman, Gregory T.
    Perry, Maura L.
    Kennedy, Robert T.
    ANALYTICAL CHEMISTRY, 2009, 81 (21) : 9072 - 9078
  • [19] In vivo monitoring of gabapentin in rats:: A microdialysis study coupled to capillary electrophoresis and laser-induced fluorescence detection
    Rada, P
    Tucci, S
    Pérez, J
    Teneud, L
    Chuecos, S
    Hernández, L
    ELECTROPHORESIS, 1998, 19 (16-17) : 2976 - 2980
  • [20] INVIVO MICRODIALYSIS OF AMINO-ACID NEUROTRANSMITTERS IN THE HIPPOCAMPUS IN AMYGDALOID KINDLED RAT
    MINAMOTO, Y
    ITANO, T
    TOKUDA, M
    MATSUI, H
    JANJUA, NA
    HOSOKAWA, K
    OKADA, Y
    MURAKAMI, TH
    NEGI, T
    HATASE, O
    BRAIN RESEARCH, 1992, 573 (02) : 345 - 348