Miniature Implantable Antennas for Biomedical Telemetry: From Simulation to Realization

被引:51
|
作者
Kiourti, Asimina [1 ,2 ]
Costa, Jorge R. [3 ,4 ]
Fernandes, Carlos A. [5 ,6 ]
Santiago, Andre G. [6 ]
Nikita, Konstantina S. [1 ,2 ]
机构
[1] Natl Tech Univ Athens, Sch Elect & Comp Engn, Athens 15780, Greece
[2] Natl Tech Univ Athens, Inst Commun & Comp Syst, Athens 15780, Greece
[3] Inst Univ Lisboa ISCTE IUL, Inst Telecomunicacoes, P-1649026 Lisbon, Portugal
[4] Inst Univ Lisboa ISCTE IUL, Dept Ciencias & Tecnol Informacao, P-1649026 Lisbon, Portugal
[5] Univ Tecn Lisboa, Inst Telecomunicacoes, P-1049001 Lisbon, Portugal
[6] Univ Tecn Lisboa, Inst Super Tecn, P-1049001 Lisbon, Portugal
关键词
Biomedical telemetry; dielectric measurements; implantable antenna; in vitro; medical implant communications service (MICS) band; MICROSTRIP ANTENNA; REFLECTION; RADIATION; DESIGN; MHZ;
D O I
10.1109/TBME.2012.2202659
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We address numerical versus experimental design and testing of miniature implantable antennas for biomedical telemetry in the medical implant communications service band (402-405 MHz). A model of a novel miniature antenna is initially proposed for skin implantation, which includes varying parameters to deal with fabrication-specific details. An iterative design-and-testing methodology is further suggested to determine the parameter values that minimize deviations between numerical and experimental results. To assist in vitro testing, a low-cost technique is proposed for reliably measuring the electric properties of liquids without requiring commercial equipment. Validation is performed within a specific prototype fabrication/testing approach for miniature antennas. To speed up design while providing an antenna for generic skin implantation, investigations are performed inside a canonical skin-tissue model. Resonance, radiation, and safety performance of the proposed antenna is finally evaluated inside an anatomical head model. This study provides valuable insight into the design of implantable antennas, assessing the significance of fabrication-specific details in numerical simulations and uncertainties in experimental testing for miniature structures. The proposed-methodology can be applied to optimize antennas for several fabrication/testing approaches and biotelemetry applications.
引用
下载
收藏
页码:3140 / 3147
页数:8
相关论文
共 50 条
  • [41] A Novel Wideband and Multi-band Implantable Antenna Design for Biomedical Telemetry
    Behih, Mohamed
    Bouttout, Farid
    Fortaki, Tarek
    Dumond, Christophe
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2022, 37 (04): : 441 - 457
  • [42] A Double-Carrier Wireless Power and Data Telemetry for Implantable Biomedical Systems
    Najjarzadegan, M.
    Ghotbi, I.
    Ashtiani, S. Jafarabadi
    Shoaei, O.
    2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 2038 - 2041
  • [43] Novel implantable antenna with miniaturized footprint size for wideband biomedical telemetry applications
    Ahmad, Sarosh
    Manzoor, Bilal
    Shair, Muhammad Muzamil
    Khan, Shahid
    Akram, Ayesha
    Ghaffar, Adnan
    Al-Gburi, Ahmed Jamal Abdullah
    Ali, Esraa Mousa
    Arpanaei, Farhad
    Alibakhshikenari, Mohammad
    FREQUENZ, 2023, 77 (5-6) : 293 - 301
  • [44] A miniature pressure system with a capacitive sensor and a passive telemetry link for use in implantable applications
    Chatzandroulis, S
    Tsoukalas, D
    Neukomm, PA
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) : 18 - 23
  • [45] Efficient Simulation of Graphene Antennas for Biomedical Applications
    Ahmed, Iftikhar
    Khoo, Eng Huat
    Li, Dongying
    2013 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2013, : 80 - 82
  • [46] Electrical Properties of Nude Rat Skin and Design of Implantable Antennas for Wireless Data Telemetry
    Karacolak, Tutku
    Topsakal, Erdem
    2008 IEEE MTT-S International Microwave Symposium Digest, Vols 1-4, 2008, : 1169 - 1172
  • [47] Dual-Band (2.4 / 4.8 GHz) Implantable Antenna for Biomedical Telemetry Applications
    Blauert, John
    Kiourti, Asimina
    2018 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2018,
  • [48] Implantable High-Gain Dental Antennas for Minimally Invasive Biomedical Devices
    Yang, Chin-Lung
    Tsai, Chi-Lin
    Chen, Sheng-Hao
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2013, 61 (05) : 2380 - 2387
  • [49] Implantable Antennas for Biomedical Applications: An Overview on Alternative Antenna Design Methods and Challenges
    Damaj, Adel
    El Misilmani, Hilal M.
    Abou Chahine, Soubhi
    PROCEEDINGS 2018 INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE COMPUTING & SIMULATION (HPCS), 2018, : 31 - 37
  • [50] On the Design of Telemetry Coils and Implantable Small Antennas for a Retinal Prosthesis to Restore Partial Vision to the Blind
    Lazzi, Gianluca
    Qusba, Amit
    Singh, Vinit
    2008 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, VOLS 1-9, 2008, : 592 - 594