The analysis of factors influencing the Frequency Response of the transformer winding

被引:0
|
作者
Banaszak, Szymon [1 ]
机构
[1] Zachodniopomorski Uniwersytet Technol Szczecinie, Katedra Elektrotechnol & Diagnostyki, PL-70313 Szczecin, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2012年 / 88卷 / 11A期
关键词
transformer; active part; Frequency Response Analysis - FRA; deformation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes results of two experiments based on frequency response measurements performed on HV transformer winding. The first of them was based on the controlled deformations of windings, while during the second one additional capacitance elements were attached to various points of the winding. These results were to be found similar to results taken from deformations, therefore it can be concluded that described axial, but also radial deformations depend mainly on capacitance changes (The analysis of factors influencing the Frequency Response of the transformer winding).
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Influence of Moisture Content Variation on Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Phung, B. T.
    Blackburn, Trevor
    2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 333 - 337
  • [22] Effect of Temperature Properties of Transformer Materials on Frequency Response Analysis of Winding
    Wang G.
    Niu C.
    Wang L.
    Li Y.
    Ye J.
    Wang T.
    Luo Y.
    He L.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (03): : 999 - 1008
  • [23] A Study on Suitability of Different Transformer Winding Models for Frequency Response Analysis
    Yousof, M. F. M.
    Ekanayake, Chandima
    Saha, Tapan K.
    Ma, Hui
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [24] Estimation of Transformer Winding Capacitances through Frequency Response Analysis - An Experimental Investigation
    Shah, Krupa
    Ragavan, K.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2013, 14 (06): : 549 - 559
  • [25] Investigation of Transformer Model Winding Deformation Using Sweep Frequency Response Analysis
    Ludwikowski, K.
    Siodla, K.
    Ziomek, W.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1957 - 1961
  • [26] Modeling of a power transformer winding for deformation detection based on frequency response analysis
    Almas, Shintemirov
    Tang, Wenhu
    Wu, Q. H.
    PROCEEDINGS OF THE 26TH CHINESE CONTROL CONFERENCE, VOL 5, 2007, : 506 - +
  • [27] Detection and quantitative diagnosis of axial displacement of transformer winding by frequency response analysis
    Miyazaki, Satoru
    Tahir, Mehran
    Tenbohlen, Stefan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (15) : 3493 - 3500
  • [28] Bushing Characteristic Impacts on On-line Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Naderi, Mohammad Salay
    Blackburn, Trevor
    Phung, B. T.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 956 - 961
  • [29] A novelty instrument inspecting transformer winding distortion based on frequency response analysis
    Dai, WJ
    Zhou, W
    Liu, BB
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 3, 2005, : 21 - 25
  • [30] Transformer Winding Deformation Diagnosis Using Middle Band Frequency Response Analysis
    Li, Yanming
    Liu, Gang
    Pang, Linhai
    Zhang, Longjun
    Lin, Zhiming
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 677 - +