Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study

被引:0
|
作者
Bai Jing [1 ,2 ]
Shi Xiao-wei [1 ]
Du Ying-feng [1 ]
Xiang Bai [1 ]
Wang Shuai [1 ]
Cao De-ying [1 ]
机构
[1] Hebei Med Univ, Sch Pharm, Shijiazhuang 050017, Peoples R China
[2] Hebei Med Univ, Hosp 4, Dept Pharm, Shijiazhuang 050017, Peoples R China
关键词
Liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS/MS); Simultaneous determination; Metformin; Glimepiride; Glipizide; Bioequivalence; ORAL ANTIDIABETIC AGENTS; SOLID-PHASE EXTRACTION; FIXED-DOSE COMBINATION; GLYBURIDE; THERAPY; REGIMEN;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium acetate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, precision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepiride in beagle dogs.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [41] Determination of lansoprazole in human plasma by rapid resolution liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study on Chinese volunteers
    Wu, Guo-Lan
    Zhou, Hui-Li
    Shentu, Jian-Zhong
    He, Qiao-Jun
    Yang, Bo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (05) : 1485 - 1489
  • [42] Quantification of roxatidine in human plasma by liquid chromatography electrospray ionization tandem mass spectrometry: Application to a bioequivalence study
    Ryu, Ju-Hee
    Choi, Sang-Jun
    Lee, Heon-Woo
    Choi, Seung-Ki
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 143 - 147
  • [43] Determination of flumazenil in human plasma by liquid chromatography-electrospray ionisation tandem mass spectrometry
    Lavén, M
    Appel, L
    Moulder, R
    Tyrefors, N
    Markides, K
    Långström, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02): : 221 - 227
  • [44] Determination of berberine in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Hua, Wenyan
    Ding, Li
    Chen, Yan
    Gong, Bin
    He, Jianchang
    Xu, Guili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 931 - 937
  • [45] Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for Determination of Protopanaxadiol in Rat Plasma
    WU Yi1
    2. College of Life Science
    3. School of Chemistry and Life Science
    4. Jilin Provincial Corps Hospital
    Chemical Research in Chinese Universities, 2009, 25 (05) : 673 - 676
  • [46] Quantitative determination of rocuronium in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Farenc, C
    Enjalbal, C
    Sanchez, P
    Bressolle, F
    Audran, M
    Martinez, J
    Aubagnac, JL
    JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) : 61 - 67
  • [47] Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for Determination of Protopanaxadiol in Rat Plasma
    Wu Yi
    Teng Guo-sheng
    Liang Yong-tao
    Zhong Da-fang
    Liu Bing
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2009, 25 (05) : 673 - 676
  • [48] Determination of palonosetron in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Ding, Li
    Chen, Yan
    Yang, Lin
    Wen, Aidong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 575 - 580
  • [49] CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD
    Derezinski, Pawel
    Klupczynska, Agnieszka
    Sawicki, Wojciech
    Kokot, Zenon J.
    ACTA POLONIAE PHARMACEUTICA, 2016, 73 (02): : 303 - 313
  • [50] A rapid and highly sensitive method for the determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a pre-clinical pharmacokinetic study
    Chakradhar, Lagishetty
    Kallem, Rajareddy
    Karthik, Arumugam
    Sundari, Bala Tripura
    Ramesh, Srirangam
    Mullangi, Ramesh
    Srinivas, Nuggehally R.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) : 58 - 63