The value of virtual touch tissue imaging quantification combined with color Doppler ultrasound and CA153 in diagnosing early breast cancer

被引:0
|
作者
Wang, Aizhu [1 ]
Wang, Bin [2 ]
Huang, Xuning [1 ]
Wang, Lehua [1 ]
Wu, Huangfu [3 ]
Fan, Huiwen [1 ]
机构
[1] Hainan Med Univ, Affiliated Hosp 2, Dept Ultrasound Med, 48 Baishuitang Rd, Haikou 570311, Hainan, Peoples R China
[2] Hainan Med Univ, Affiliated Hosp 2, Dept Intervent Radiol, Haikou, Hainan, Peoples R China
[3] Hainan Med Univ, Affiliated Hosp 2, Dept Breast & Thyroid Surg, Haikou, Hainan, Peoples R China
关键词
Breast cancer; virtual touch tissue imaging quantification; color Doppler ultrasound; carbohydrate antigen 153; diagnostic value; ELASTOGRAPHY; CHEMOTHERAPY; CELLS; CEA;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To explore the value of virtual touch tissue imaging quantification combined with color Doppler ultrasound and carbohydrate antigen 153 (CA153) in diagnosis of early breast cancer. Methods: Clinical data of 196 patients with breast masses were collected and analyzed proactively. Among these patients, 89 patients were confirmed with malignant breast tumor and 107 patients were confirmed with benign breast tumor according to final pathological report. The breast imaging reporting and data system (BI-RADS) grading quantitative score, transverse shear wave velocity (SWV), and CA153 level of all patients were analyzed. Results: The BI-RADS grading quantitative score, SWV, and CA153 level of the malignant tumor group were all significantly higher than those of the benign tumor group (all P<0.05). The area under the receiver operating characteristic curve (AUC) of SWV in diagnosing breast cancer was 0.855, and when SWV was 4.205 m/s, its sensitivity and specificity were 0.640 and 0.981, respectively; The AUC of BI-RADS score in diagnosing breast cancer was 0.797, and when the BI-RADS grading quantitative score was 3.5 points, its sensitivity and specificity were 0.798 and 0.636, respectively. The AUC of CA153 in diagnosing breast cancer was 0.838, and when the CA153 level was 19.99 U/mL, its sensitivity and specificity were 0.663 and 0.981, respectively. In addition, the AUC of SWV combined with BI-RADS grading quantitative score and CA153 in diagnosing breast cancer was 0.978, and its sensitivity and specificity were 0.910 and 0.953, respectively. Conclusion: Virtual touch tissue imaging quantification combined with color Doppler ultrasound and CA153 is of a high value in the diagnosis of breast cancer, so it is worthy of clinical application.
引用
收藏
页码:8102 / 8109
页数:8
相关论文
共 50 条
  • [41] Monitoring of postoperative neutrophil-to-lymphocyte ratio, D-dimer, and CA153 in: Diagnostic value for recurrent and metastatic breast cancer
    Ren, Zhiyao
    Yang, Jing
    Liang, Jiahui
    Xu, Yunfeng
    Lu, Guanda
    Han, Yanxun
    Zhu, Jie
    Tan, Husheng
    Xu, Tao
    Ren, Min
    FRONTIERS IN SURGERY, 2023, 9
  • [42] Clinical value of serum biomarkers CA153, CEA, and white blood cells in predicting sentinel lymph node metastasis of breast cancer
    Fan, Yuan
    Chen, Xiuyuan
    Li, Hongjiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2020, 13 (11): : 2889 - 2894
  • [43] CONVENTIONAL US AND 2-D SHEAR WAVE ELASTOGRAPHY OF VIRTUAL TOUCH TISSUE IMAGING QUANTIFICATION: CORRELATION WITH IMMUNOHISTOCHEMICAL SUBTYPES OF BREAST CANCER
    Liu, Hui
    Wan, Jing
    Xu, Guang
    Xiang, Li-Hua
    Fang, Yan
    Ding, Shi-Si
    Jiang, Xiao
    Sun, Li-Ping
    Zhang, Yi-Feng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (10): : 2612 - 2622
  • [44] Relationship between parameters from virtual touch tissue quantification (VTQ) imaging with clinicopathologic prognostic factors in women with invasive ductal breast cancer
    Xie, Juan
    Wu, Rong
    Xu, Hui-Xiong
    Yao, Ming-Hua
    Xu, Guang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (10): : 6644 - 6652
  • [45] Virtual touch imaging quantification shear-wave elastography for breast lesions: the diagnostic value of qualitative and quantitative features
    Luo, T.
    Zhang, J. W.
    Zhu, Y.
    Jia, X. H.
    Dong, Y. J.
    Zhan, W. W.
    Zhou, J. Q.
    CLINICAL RADIOLOGY, 2021, 76 (04) : 316.e1 - 316.e8
  • [46] Application value of conventional ultrasound combined with shear wave elastography in diagnosing triple negative breast cancer
    Sheng, Changrui
    Gao, Shanshan
    Yan, Liming
    Yin, Hua
    Hu, Jingjing
    Ye, Zhiying
    Wei, Xiuzhi
    GLAND SURGERY, 2021, 10 (06) : 1980 - 1988
  • [47] Application of color doppler ultrasound combined with X-ray molybdenum target in the diagnosis of breast cancer
    Peng, Guiping
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2023, 44 (02) : 130 - 130
  • [48] Diagnostic value of ultrasound and color Doppler in identifying axillary lymph node metastases in patients with breast cancer
    Couto, D
    Dias, M
    Gonçalo, M
    Pinto, E
    de Oliveira, CF
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2004, 25 (05) : 568 - 570
  • [49] Reliability Analysis of Acoustic Radiation Force Impulse Ultrasound Imaging With Virtual Touch Tissue Quantification Ex Vivo Ox Liver
    Yang, Long
    Yuan, Jianjun
    Wang, Qi
    Wu, Gang
    Guo, Wen-Qing
    Wang, Wen-Wei
    Zhao, Bing
    ULTRASOUND QUARTERLY, 2015, 31 (01) : 59 - 62
  • [50] Diagnostic value of ultrasound combined with magnetic resonance imaging in different stages of breast cancer
    Pan, Qiaohong
    Ji, Jianwu
    ONCOLOGY LETTERS, 2019, 17 (01) : 209 - 214