Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT

被引:10
|
作者
Yamashita, Shozo [1 ,2 ]
Yokoyama, Kunihiko [3 ]
Onoguchi, Masahisa [2 ]
Yamamoto, Haruki [1 ]
Hiko, Shigeaki [1 ]
Horita, Akihiro [1 ]
Nakajima, Kenichi [4 ]
机构
[1] Publ Cent Hosp Matto Ishikawa, Div Radiol, Haku San, Ishikawa 9248588, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Hlth Sci, Kanazawa, Ishikawa 9200942, Japan
[3] Publ Cent Hosp Matto Ishikawa, PET Imaging Ctr, Haku San, Ishikawa 9248588, Japan
[4] Kanazawa Univ Hosp, Dept Nucl Med, Kanazawa, Ishikawa 9208641, Japan
关键词
Deep-inspiration breath-hold (DIBH) PET/CT; Respiratory-gated (RG) PET/CT; Pulmonary lesion; Reconstruction parameters; CELL LUNG-CANCER; THORAX; IMPACT;
D O I
10.1007/s12149-013-0774-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [31] Determination of the optimal acquisition protocol of breath-hold PET/CT for the diagnosis of thoracic lesions
    Mitsumoto, Katsuhiko
    Abe, Koichiro
    Sakaguchi, Yuichi
    Zhang, Tiejiao
    Tachiya, Yosuke
    Ohya, Nobuyoshi
    Baba, Shingo
    Sasaki, Masayuki
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (12) : 1148 - 1154
  • [32] Inspiration breath-hold data acquisition for thoracic PET/CT without respiratory gating system: Comparison with a conventional method
    Ando, Akira
    Shuke, Noriyuki
    Onishi, Takuya
    Kimishima, Makoto
    Saito, Koji
    Yamamoto, Kouki
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [33] The impact of deep-inspiration breath-hold total-body PET/CT imaging on thoracic 18F-FDG avid lesions compared with free-breathing
    Cui, Yingpu
    Jia, Jin
    Yan, Qianqian
    He, Xiaoxiao
    Yuan, Keqing
    Li, Zhijian
    Zhang, Weiguang
    Wu, Runze
    Zhao, Yumo
    Tang, Si
    Fan, Wei
    Hu, Yingying
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 177
  • [34] Comparison of an original respiratory gated PET method, based on breath-hold CT, versus ungated PET.
    Daouk, J.
    Fin, L.
    Bailly, P.
    Meyer, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S145 - S145
  • [35] Comparison of a Free-Breathing CT and an Expiratory Breath-Hold CT with Regard to Spatial Alignment of Amplitude-Based Respiratory-Gated PET and CT Images
    van der Vos, Charlotte S.
    Grootjans, Willem
    Meeuwis, Antoi P. W.
    Slump, Cornelis H.
    Oyen, Wim J. G.
    de Geus-Oei, Lioe-Fee F.
    Visser, Eric P.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2014, 42 (04) : 269 - 273
  • [36] AW-OSEM parameter optimization for selected events related to the breath-hold CT position in respiratory-gated PET acquisitions
    Daouk, J.
    Fin, L.
    Bailly, P.
    Meyer, M-E.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1323 - 1326
  • [37] Respiratory-gated FDG PET/CT for evaluation of pulmonary nodules
    Aga, Fumitoshi
    Yamamoto, Yuka
    Maeda, Yukito
    Takahashi, Yosuke
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [38] Combined CT and SPECT deep inspiration breath-hold acquisition in myocardial imaging
    Clerc, Olivier
    Buechel, Ronny
    Fuchs, Tobias
    Possner, Mathias
    Svetlana, Dougoud
    Stehli, Julia
    Kaufmann, Philipp
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [39] Evaluation on the feasibility of a 20-second Breath-hold Acquisition in Total-body PET/CT in Pulmonary adenocarcinoma
    Duan, Yanhua
    Cui, Xiao
    Chai, Leiying
    Li, Kun
    Zhao, Minjie
    Zan, Keyu
    Li, Chenwei
    Wang, Ying
    Cheng, Zhaoping
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [40] Usefulness of a deep-inspiration breath-hold 18F-FDG PET/CT technique in diagnosing liver, bile duct, and pancreas tumors
    Nagamachi, Shigeki
    Wakamatsu, Hideyuki
    Kiyohara, Shogo
    Fujita, Seigo
    Futami, Shigemi
    Arita, Hideo
    Nishii, Ryuichi
    Tamura, Shozo
    Kawai, Keiichl
    NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (05) : 326 - 332