Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT

被引:10
|
作者
Yamashita, Shozo [1 ,2 ]
Yokoyama, Kunihiko [3 ]
Onoguchi, Masahisa [2 ]
Yamamoto, Haruki [1 ]
Hiko, Shigeaki [1 ]
Horita, Akihiro [1 ]
Nakajima, Kenichi [4 ]
机构
[1] Publ Cent Hosp Matto Ishikawa, Div Radiol, Haku San, Ishikawa 9248588, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Hlth Sci, Kanazawa, Ishikawa 9200942, Japan
[3] Publ Cent Hosp Matto Ishikawa, PET Imaging Ctr, Haku San, Ishikawa 9248588, Japan
[4] Kanazawa Univ Hosp, Dept Nucl Med, Kanazawa, Ishikawa 9208641, Japan
关键词
Deep-inspiration breath-hold (DIBH) PET/CT; Respiratory-gated (RG) PET/CT; Pulmonary lesion; Reconstruction parameters; CELL LUNG-CANCER; THORAX; IMPACT;
D O I
10.1007/s12149-013-0774-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
    Shozo Yamashita
    Kunihiko Yokoyama
    Masahisa Onoguchi
    Haruki Yamamoto
    Shigeaki Hiko
    Akihiro Horita
    Kenichi Nakajima
    Annals of Nuclear Medicine, 2014, 28 : 1 - 10
  • [2] Respiratory-gated and deep inspiration breath-hold FDG PET/CT protocols for evaluation of pulmonary and abdominal lesions
    Aga, Fumitoshi
    Yamamoto, Yuka
    Maeda, Yukito
    Takahashi, Yousuke
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] Deep-inspiration breath-hold PET/CT of the thorax
    Nehmeh, Sadek A.
    Erdi, Yusuf E.
    Meirelles, Gustavo S. P.
    Squire, Olivia
    Larson, Steven M.
    Humm, John L.
    Schoder, Heiko
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (01) : 22 - 26
  • [4] Fundamental evaluation for optimized imaging methods between respiratory gated PET/CT and deep-inspiration breath hold PET/CT with rapid acquisition
    Yamashita, S.
    Onoguchi, M.
    Hiko, S.
    Yamamoto, H.
    Horita, A.
    Yokoyama, K.
    Tsuji, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S619 - S619
  • [5] Optimum emission time in deep-inspiration breath-hold PET–CT: a preliminary result
    Koichi Miyashita
    Ukihide Tateishi
    Yuji Nishiyama
    Ryogo Minamimoto
    Kazuya Shizukuishi
    Tomio Inoue
    Annals of Nuclear Medicine, 2010, 24 : 559 - 563
  • [6] Feasibility of a deep-inspiration breath-hold [18F]AlF-NOTA-LM3 PET/CT imaging on upper-abdominal lesions in NET patients: in comparison with respiratory-gated PET/CT
    Zhang, Haiqiong
    Liu, Meixi
    Shi, Ximin
    Ma, Jiangyu
    Ren, Chao
    Huang, Zhenghai
    Wang, Ying
    Jing, Hongli
    Huo, Li
    EJNMMI PHYSICS, 2024, 11 (01):
  • [7] Feasibility of a deep-inspiration breath-hold 18F-NOTA-LM3 PET/CT imaging in patients with upper-abdominal neuroendocrine tumors: in comparison with respiratory-gated PET/CT
    Zhang, Haiqiong
    Liu, Meixi
    Shi, Ximin
    Ma, Jiangyu
    Ren, Chao
    Huang, Zhenghai
    Wang, Ying
    Huo, Li
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [8] 20-s acquisition of deep-inspiration breath-hold PET/CT: Clinical feasibility for imaging of lung cancer
    Torizuka, Tatsuo
    Tanizaki, Yasuo
    Kanno, Toshihiko
    Futatsubashi, Masami
    Yoshikawa, Etsuji
    Okada, Hiroyuki
    Ouchi, Yasuomi
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [9] Single 20-Second Acquisition of Deep-Inspiration Breath-Hold PET/CT: Clinical Feasibility for Lung Cancer
    Torizuka, Tatsuo
    Tanizaki, Yasuo
    Kanno, Toshihiko
    Futatsubashi, Masami
    Yoshikawa, Etsuji
    Okada, Hiroyuki
    Ouchi, Yasuomi
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (10) : 1579 - 1584
  • [10] Reduction of respiratory effects on lung PET imaging with respiratory-gated acquisition associated with breath-hold CT
    Morvan, J.
    El Esper, I.
    Saidi, L.
    Moullart, V.
    Daouk, J.
    Fin, L.
    Bailly, P.
    Meyer, M. -E.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (12): : 600 - 606