Enhancement of the resolution of full-field optical coherence tomography by using a colour image sensor

被引:0
|
作者
Kalyanov, A. L. [1 ]
Lychagov, V. V. [1 ]
Smirnov, I. V. [1 ]
Ryabukho, V. P. [1 ,2 ]
机构
[1] NG Chernyshevskii Saratov State Univ, Saratov 410012, Russia
[2] Russian Acad Sci, Inst Precis Mech & Control, Saratov 410028, Russia
基金
俄罗斯基础研究基金会;
关键词
full-field interferometry; interferometry in white light; white balance; fill-field optical coherence tomography; IN-VIVO; TEMPORAL COHERENCE; LENGTH;
D O I
10.1070/QE2013v043n08ABEH014984
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of white balance in a colour image detector on the resolution of a full-field optical coherence tomograph (FFOCT) is studied. The change in the interference pulse width depending on the white balance tuning is estimated in the cases of a thermal radiation source (incandescent lamp) and a white light emitting diode. It is shown that by tuning white balance of the detector in a certain range, the FFOCT resolution can be increased by 20% as compared to the resolution, attained with the use of a monochrome detector.
引用
收藏
页码:762 / 767
页数:6
相关论文
共 50 条
  • [1] Image enhancement for multilayer information retrieval by using full-field optical coherence tomography
    Chang, Shoude
    Cai, Xianyang
    Flueraru, Costel
    [J]. APPLIED OPTICS, 2006, 45 (23) : 5967 - 5975
  • [2] Nonlocally adaptive image enhancement system for full-field optical coherence tomography
    Cho, Po Chuan
    Chen, Wen Hui
    Shih, Cheng Yuan
    Chang, Jui Hsuan
    [J]. OPTICAL ENGINEERING, 2021, 60 (07)
  • [3] Ultrahigh-resolution full-field optical coherence tomography
    Dubois, A
    Grieve, K
    Moneron, G
    Lecaque, R
    Vabre, L
    Boccara, C
    [J]. APPLIED OPTICS, 2004, 43 (14) : 2874 - 2883
  • [4] High resolution full-field optical coherence tomography using high dynamic range image processing
    Leong-Hoi, A.
    Claveau, R.
    Montgomery, P. C.
    Serio, B.
    Uhring, W.
    Anstotz, F.
    Flury, M.
    [J]. OPTICAL MICRO- AND NANOMETROLOGY VI, 2016, 9890
  • [5] Effects of temporal and spatial coherence on resolution in full-field optical coherence tomography
    Gao, Wanrong
    [J]. JOURNAL OF MODERN OPTICS, 2015, 62 (21) : 1764 - 1774
  • [6] Imaging of ocular tissues using ultrahigh resolution full-field optical coherence tomography
    Le Gargasson, JF
    Grieve, K
    Paques, M
    Dubois, A
    Boccara, C
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U1003 - U1003
  • [7] Stroboscopic ultrahigh-resolution full-field optical coherence tomography
    Moneron, G
    Boccara, AC
    Dubois, A
    [J]. OPTICS LETTERS, 2005, 30 (11) : 1351 - 1353
  • [8] Full-field optical coherence tomography system with controllable longitudinal resolution
    Nitta, Kouichi
    Li, Tingyu
    Motoyama, Toshiki
    Matoba, Osamu
    Yoshimura, Takeaki
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (11): : 8897 - 8903
  • [9] Image contrast reduction mechanism in full-field optical coherence tomography
    Gao, Wanrong
    [J]. JOURNAL OF MICROSCOPY, 2016, 261 (03) : 199 - 216
  • [10] Image contrast correction method in full-field optical coherence tomography
    Mu, Ning
    Gao, Wanrong
    Zhou, Yawen
    [J]. OPTICAL ENGINEERING, 2019, 58 (07)