EVALUATION OF AN AUTOMATIC SYSTEM FOR DETECTION AND POSITIONING OF SMALL PORE DEFECTS USING DIGITAL RADIOGRAPHY

被引:3
|
作者
Lindgren, Erik [1 ]
Hammar, Lars [1 ]
机构
[1] Chalmers, Dept Mat & Mfg Technol, SE-41296 Gothenburg, Sweden
关键词
X-ray Imaging; Digital Radiography; Non Destructive Testing; CALIBRATION; TOMOGRAPHY; GEOMETRY;
D O I
10.1063/1.4789239
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A recently developed algorithm for positioning of small defects within metal bodies using digital radiography has been experimentally validated. The algorithm has been validated in the high contrast to noise limit. A calibration method has also been developed and validated. The average error in defect interspacings are found to be approximately 0.03 mm with a maximum at 0.2 mm, this is at the same order as the errors predicted by simulations. The relative error in interspacings are all less than 2% which is comparable to simulated ideal case at 0.25%.
引用
收藏
页码:1646 / 1653
页数:8
相关论文
共 50 条
  • [31] Radiopacity evaluation of different types of resin restorative materials using a digital radiography system
    Ceyda Gündoğdu
    Sinem Akgül
    [J]. Oral Radiology, 2023, 39 : 646 - 653
  • [32] Radiopacity evaluation of different types of resin restorative materials using a digital radiography system
    Guendogdu, Ceyda
    Akguel, Sinem
    [J]. ORAL RADIOLOGY, 2023, 39 (04) : 646 - 653
  • [33] Detection of Natural and Simulated Periodontal Defects Using Cone-Beam Computed Tomography and Digital Intraoral Radiography
    Misirli, Melis
    Aksoy, Secil
    Tumer, Hayriye
    Bilginaylar, Kani
    Karaoglulari, Suzan
    Berberoglu, Atilla
    Orhan, Kaan
    Icen, Murat
    [J]. JOURNAL OF CONTEMPORARY MEDICAL SCIENCES, 2022, 8 (01): : 38 - 43
  • [34] Evaluation of a Real-Time Positioning Assistance Simulator System for Skull Radiography Using the Microsoft Kinect
    Kurata, T.
    Ono, M.
    Kozono, K.
    Fukuyoshi, R.
    Sato, S.
    Toyofuku, F.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 170 - 170
  • [35] Nodule detection in digital chest radiography:: Effect of system noise
    Håkansson, M
    Båth, M
    Börjesson, S
    Kheddache, S
    Johnsson, ÅA
    Månsson, LG
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 97 - 101
  • [36] Comparative Evaluation of Periodontal Osseous Defects Using Direct Digital Radiography and Cone-Beam Computed Tomography
    Mark, Ruhi
    Mohan, Ranjana
    Gundappa, M.
    Balaji, M. D. Saravana
    Vijay, V. K.
    Umayal, M.
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 306 - 311
  • [37] Quality and dose optimization in canine chest radiography using a digital radiography system
    Santana de Souza, Sergio Augusto
    Fattori Alves, Allan Felipe
    Mamprim, Maria Jaqueline
    Pina, Diana Rodrigues
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 195
  • [38] Automatic Detection of Missing Access Points in Indoor Positioning System
    Gorak, Rafal
    Luckner, Marcin
    [J]. SENSORS, 2018, 18 (11)
  • [39] Automatic System for Detection and Positioning of Impacts in Metals Based on Arduino
    Moron, Carlos
    Ferrandez, Daniel
    Saiz, Pablo
    Moron, Alberto
    [J]. SHOCK AND VIBRATION, 2019, 2019
  • [40] A system for automatic detection of defects in welding radiographic images
    Vilar, R
    Zapata, J
    Ruiz, R
    [J]. Proceedings of the Fifth IASTED International Conference on Visualization, Imaging, and Image Processing, 2005, : 1 - 6