Experimental analysis on reinforced concrete beams enlarged with ferrocement retrofit system

被引:1
|
作者
Linh Van Hong Bui [1 ,2 ]
Saiwimarn, Supawit [3 ]
Sirimontree, Sayan [3 ]
Thongchom, Chanachai [5 ]
Keawsawasvong, Suraparb [3 ]
Phuoc Trong Nguyen [4 ]
Yen Thi Hai Nguyen [5 ]
Lawongkerd, Jintara [3 ]
Ngamkhanong, Chayut [6 ]
Thanh-Truong Nguyen [7 ,8 ]
机构
[1] Ton Duc Thang Univ, Inst Computat Sci, Div Construct Computat, Ho Chi Minh City, Vietnam
[2] Ton Duc Thang Univ, Fac Civil Engn, Ho Chi Minh City, Vietnam
[3] Thammasat Univ, Thammasat Sch Engn, Dept Civil Engn, Khlong Luang 12120, Pathum Thani, Thailand
[4] Ho Chi Minh City Open Univ, Fac Civil Engn, 97 Vo Van Tan,Dist 3, Ho Chi Minh City 700000, Vietnam
[5] Ind Univ Ho Chi Minh City, Fac Civil Engn, 12 Nguyen Van Bao St,Ward 4, Ho Chi Minh City, Vietnam
[6] Chulalongkorn Univ, Fac Engn, Dept Civil Engn, Bangkok 10330, Thailand
[7] Ho Chi Minh City Univ Technol HCMUT, Ind Maintenance Training Ctr, Ward 14,Dist 10, Ho Chi Minh City, Vietnam
[8] Vietnam Natl Univ Ho Chi Minh City, Ho Chi Minh City, Vietnam
关键词
Ferrocement; Flexural behavior; Adhesion; Strengthening; Retrofit; THROUGH-SECTION TECHNIQUE; RC BEAMS; BOND STRENGTH; SHEAR; BEHAVIOR; PERFORMANCE; SUBSTRATE; REPAIR; CARBON;
D O I
10.1007/s41062-022-00935-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports the experimental results obtained from the first phase of the study involving the loading tests for reinforced concrete (RC) beams retrofitted with the jacketing ferrocement system. Five beams, in which one is the control beam, and the other four beams are enlarged with ferrocement jacket, are prepared for the four-point bending tests. The obtained results indicate that the retrofit of the RC beams with ferrocement jacket alone induces the adverse influence on the member performance in terms of the load-carrying capacity, stiffness, safety, and ductility. In contrast, the strengthening with the ferrocement jacket incorporating addition of the steel tension bars noticeably improves the flexural efficiency of the RC beams. In such circumstance, besides the amelioration in the capacity, stiffness, and ductility, the strengthened beams exhibit numerous flexural cracks with narrow spacing and small width following the yielding of longitudinal reinforcement and the crushing of concrete at loading area. In addition, the continuity for the stress transfer at the ferrocement-concrete bonded interface remarkably governs the failure mechanism and ductility of the retrofitted beams. The discontinuity of the adherence between ferrocement and concrete by shear connector with anchored bars coupling the addition of the tensile reinforcement positively impacts the performance of the ferrocement-retrofitted beams. Sectional analysis cannot predict the flexural strength of the beams retrofitted with only ferrocement, while it can accurately assess the maximum capacity of the control beam and the beams with both ferrocement jacket and additional steels.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Applying the Ferrocement Concept in Construction of Concrete Beams Incorporating Reinforced Mortar Permanent Forms
    Fahmy, Ezzat H.
    Shaheen, Yousry B. I.
    Abdelnaby, Ahmed Mahdy
    Abou Zeid, Mohamed N.
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2014, 8 (01) : 83 - 97
  • [23] Hybrid shear strengthening system for reinforced concrete beams: An experimental study
    Ebead, Usama
    Saeed, Huda
    ENGINEERING STRUCTURES, 2013, 49 : 421 - 433
  • [24] Moment Capacity and Ductility of Reinforced Concrete Beams Strengthened with Ferrocement Including Steel Bars
    Xiong, Guangjing
    Ye, Surong
    Zhu, Zhanxian
    ADVANCED SCIENCE LETTERS, 2011, 4 (8-10) : 3249 - 3255
  • [25] Local Retrofit of Reinforced Concrete Structures by the ACM System
    Sorace, Stefano
    Terenzi, Gloria
    Fuso, Elena
    BUILDINGS, 2021, 11 (12)
  • [26] Flexural behavior of reinforced concrete beams strengthened with a hybrid inorganic matrix - steel fiber retrofit system
    Papakonstantinou, Christos G.
    Katakalos, Konstantinos
    STRUCTURAL ENGINEERING AND MECHANICS, 2009, 31 (05) : 567 - 585
  • [27] Experimental Study on Seismic Retrofit of Reinforced Concrete Buildings using Combination of Column-Jacketing and Supplemental Beams
    Huang, Chao-Hsun
    Lin, Min-Lang
    Chen, Wei-Hong
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ARCHITECTURAL, CIVIL AND HYDRAULICS ENGINEERING (ICACHE 2015), 2016, 44 : 46 - 49
  • [28] An Application of an Optical Measuring System to Reinforced Concrete Beams Analysis
    Tworzewski, Pawel
    Goszczynska, Barbara
    2016 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-CHENGDU), 2016,
  • [29] Experimental study and statistical analysis of crack patterns of reinforced concrete beams
    Zhao, Shun-Bo
    Guan, Jun-Feng
    Zhang, Xue-Peng
    Cheng, Xiao-Tian
    Huang, Cheng-Kui
    Gongcheng Lixue/Engineering Mechanics, 2008, 25 (12): : 141 - 146
  • [30] Experimental and Numerical Analysis of the Fire Resistance of Reinforced Geopolymer Concrete Beams
    Wu, Borui
    Wang, Ke
    Yao, Yao
    Journal of Structural Engineering, 2025, 151 (01)