MEA Recording System Circuit Implementation

被引:0
|
作者
Fambrini, Francisco [1 ]
Saito, Jose Hiroki [1 ,2 ]
Del Val Cura, Luis Mariano [2 ]
机构
[1] Fed Univ Sao Carlos UFSCar, Sao Carlos, SP, Brazil
[2] Fac Campo Limpo Paulista FACCAMP, Grad Course Comp Sci, Campo Limpo Paulista, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
micro-electrode array; MEA; amplifier; filters; analog multiplexer; electrophysiological signal; AD converter;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a Micro-Electrode Array (MEA) recording system with novel concept of a multiplexer coupled prior to the amplifier and filtering stages. It is described all the recording system, since the pre-amplifier, analog channel multiplexing, amplifier and filter, and AD conversion. For the AD conversion, it was used a commercial module called BeagleBoneBlack, which is an open source board, based on a 32-bit microprocessor, making it much easier to search for neuronal signals from the in-vitro culture on MEA. As result, it is presented the first one second recording data at 1 kHz frequency of Wistar rat embryo hippocampal neuron culture. One importance of such an in-vitro culture recording in human factor is in pharmacological drug tests, before its approval for medicinal use.
引用
收藏
页码:8515 / 8520
页数:6
相关论文
共 50 条
  • [1] Design and implementation of an embedded surveillance system with video streaming recording triggered by an infrared sensor circuit
    Bai, Ying-Wen
    Hsu, Jui-Po
    Teng, Hen
    Lin, Hsing-Eng
    [J]. 2007 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES, VOLS 1-3, 2007, : 335 - 340
  • [2] NANOSECOND COINCIDENCE CIRCUIT FOR A MULTICHANNEL RECORDING SYSTEM
    SUVOROV, VM
    SHCHETKO.AI
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (04): : 776 - &
  • [3] A 32-Channel Neural Recording System with a Liquid-Crystal Polymer MEA
    Na, Seung-In
    Kim, Susie
    Kim, Taehoon
    Lee, Hyongmin
    Lee, Hyunjoong
    Kim, Suhwan
    [J]. 2013 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2013, : 13 - 16
  • [4] A recording transmission measuring system for telephone circuit testing
    Best, FH
    [J]. BELL SYSTEM TECHNICAL JOURNAL, 1933, 12 : 22 - 34
  • [5] Mea-based recording of neuronal activity in vitro
    Jimbo, Y.
    [J]. ARCHIVES ITALIENNES DE BIOLOGIE, 2007, 145 (3-4): : 289 - 297
  • [6] Design and Implementation of hybrid shingled recording RAID system
    Lu, Zheng-wu
    Zhou, Gang
    [J]. 2016 IEEE 14TH INTL CONF ON DEPENDABLE, AUTONOMIC AND SECURE COMPUTING, 14TH INTL CONF ON PERVASIVE INTELLIGENCE AND COMPUTING, 2ND INTL CONF ON BIG DATA INTELLIGENCE AND COMPUTING AND CYBER SCIENCE AND TECHNOLOGY CONGRESS (DASC/PICOM/DATACOM/CYBERSC, 2016, : 937 - 942
  • [7] Implementation of a Parallel Fuzzy System in the FPGA Circuit
    Poplawski, Marek
    [J]. ARTIFICIAL INTELLIGENCE AND SOFT COMPUTING, ICAISC 2016, 2016, 9692 : 276 - 283
  • [8] Circuit design and implementation of a unified chaotic system
    Li, Yuxia
    Tang, Wallace K. S.
    Chen, Guanrong
    [J]. 2006 INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS PROCEEDINGS, VOLS 1-4: VOL 1: SIGNAL PROCESSING, 2006, : 2569 - 2572
  • [9] A novel hyperchaotic system and its circuit implementation
    Fang, Jie
    Deng, Wei
    Wu, Yanmin
    Ding, Guoqiang
    [J]. OPTIK, 2014, 125 (20): : 6305 - 6311
  • [10] A Sinusoidally Driven Lorenz System and Circuit Implementation
    Han, Chunyan
    Yu, Simin
    Wang, Guangyi
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2015, 2015