Performance assessment of an integrated free cooling and solar powered single-effect lithium bromide-water absorption chiller

被引:93
|
作者
Ali, Ahmed Hamza H. [1 ]
Noeres, Peter [2 ]
Pollerberg, Clemens [2 ]
机构
[1] Assiut Univ, Fac Engn, Dept Mech Engn, Assiut 71516, Egypt
[2] UMSICHT, Fraunhofer Inst Environm Safety & Energy Technol, D-46047 Oberhausen, Germany
关键词
Solar cooling; Free cooling; Absorption chillers; Lithium bromide-water;
D O I
10.1016/j.solener.2008.04.011
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, performance assessment of an integrated cooling plant having both free cooling system and solar powered single-effect lithium bromide-water absorption chiller in operation since August 2002 in Oberhausen, Germany, was performed. A floor space of 270 m(2) is air-conditioned by the plant. The plant includes 35.17 kW cooling (10-RT) absorption chiller, vacuum tube collectors' aperture area of 108 m(2), hot water storage capacity of 6.8 m(3), cold water storage capacity of 1.5 m(3) and a 134 kW cooling tower. The results show that free cooling in some cooling months can be up to 70% while it is about 25% during the 5 years period of the plant operation. For sunny clear sky days with equal incident solar radiation, the daily solar heat fraction ranged from 0.33 to 0.41, collectors' field efficiency ranged from 0.352 to 0.492 and chiller COP varies from 0.37 to 0.81, respectively. The monthly average value of solar heat fraction varies from 31.1% up to 100% and the five years average value of about 60%. The monthly average collectors' field efficiency value varies from 34.1% up 41.8% and the five-year average value amounts about 28.3%. Based on the obtained results, the specific collector area is 4.23 (m(2)/kW(cold)) and the solar energy system support of the institute heating system for the duration from August 2002 to November 2007 is 8124 kWh. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1021 / 1030
页数:10
相关论文
共 50 条
  • [31] Energy analysis of lithium bromide-water and lithium chloride-water based single effect vapour absorption refrigeration system: A comparison study
    Ahmad, Tausif
    Azhar, Md
    Sinha, M. K.
    Meraj, Md
    Mahbubul, Islam Mohammed
    Ahmad, Akbar
    [J]. CLEANER ENGINEERING AND TECHNOLOGY, 2022, 7
  • [32] Performance analysis of a solar single-effect absorption/compression hybrid refrigeration system with integrated absorption energy storage
    Song, Mengyu
    Li, Nianping
    Shi, Fangning
    A, Yongga
    Liu, Qingqing
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2024, 312
  • [33] Experimental studies of a single-effect absorption refrigerator using aqueous lithium-bromide: Effect of operating condition to system performance
    Aphornratana, Satha
    Sriveerakul, Thanarath
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (02) : 658 - 669
  • [34] DAILY EXERGY ASSESSMENT OF LIBR-WATER ABSORPTION CHILLER USED FOR SOLAR COOLING
    Onan, Cenk
    Ozkan, Derya B.
    [J]. ES2010: PROCEEDINGS OF ASME 4TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 1, 2010, : 869 - 878
  • [35] Modeling an integral dual solar/gas fired generator for a water-lithium bromide absorption chiller
    Department of Mechanical Engineering, Ohio State University, Columbus, OH 43210, United States
    [J]. ASME Adv Energy Syst Div Publ AES, (159-165):
  • [36] Thermo-economic analysis, energy modeling and reconstructing of components of a single effect solar-absorption lithium bromide chiller for energy performance enhancement
    FathiAlmas, Yousef
    Ghadamian, Hossein
    Aminy, Mohammad
    Moghadasi, Meisam
    Amirian, Hajar
    Hoseinzadeh, Siamak
    Garcia, Davide Astiaso
    [J]. ENERGY AND BUILDINGS, 2023, 285
  • [37] Experimental evaluation of a direct air-cooled lithium bromide-water absorption prototype for solar air conditioning
    Gonzalez-Gil, A.
    Izquierdo, M.
    Marcos, J. D.
    Palacios, E.
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (16) : 3358 - 3368
  • [38] Influence of the Average Daily Outdoor Air Parameters on the Efficiency of Solar Lithium Bromide-Water Absorption Refrigeration Machine
    Malinina, O. S.
    Baranenko, A. V.
    Zaitsev, A. V.
    [J]. OIL AND GAS ENGINEERING (OGE-2018), 2018, 2007
  • [39] Research on increasing the gas turbine generating capacity by intake air cooling using a lithium bromide-water absorption system
    Jiang, Zhoushu
    Hu, Yacai
    Tu, Chuanjiang
    Tu, Jin
    [J]. Dongli Gongcheng/Power Engineering, 1999, 19 (04): : 300 - 304
  • [40] The development of a dynamic single effect, lithium bromide absorption chiller model with enhanced generator fidelity
    Misenheimer, Corey T.
    Terry, Stephen D.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 574 - 587