Bismuth-based porous screen-printed carbon electrode with enhanced sensitivity for trace heavy metal detection by stripping voltammetry

被引:72
|
作者
Chen, Chen [1 ,2 ]
Niu, Xiangheng [1 ,2 ]
Chai, Yan [1 ,2 ]
Zhao, Hongli [4 ]
Lan, Minbo [1 ,2 ,3 ]
机构
[1] E China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] E China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China
[3] E China Univ Sci & Technol, Minist Educ, Key Lab Ultrafine Mat, Shanghai 200237, Peoples R China
[4] E China Univ Sci & Technol, Inst Appl Chem, Shanghai 200237, Peoples R China
关键词
Porous screen-printed carbon electrode; Bismuth film; Stripping voltammetry; Lead(II); Cadmium(II); ANTIMONY FILM ELECTRODE; POWDER;
D O I
10.1016/j.snb.2012.12.109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we report a new disposable bismuth-coated porous screen-printed carbon electrode (Bi-P-SPCE) for trace heavy metal ions detection. The Bi-P-SPCE was fabricated by two processes: firstly, the porous screen-printed carbon electrode (P-SPCE) was prepared by combing a printing procedure of a graphite-based layer doped with CaCO3 powders with a subsequent dissolution of these powders; secondly, a Bi film layer was formed on the P-SPCE by in situ electrodepositing Bi(III) along with accumulating analytes. Due to the rough surface, large active area and low background noise of P-SPCE, the electrode exhibited significantly enhanced sensitivity, for lead(II) and cadmium(II) detection compared to screen-printed carbon electrode (SPCE) and glassy carbon electrode (GCE). With a preconcentration at -1.2 V (vs. Ag/AgCl) for 300 s, the detection limits obtained on the proposed Bi-P-SPCE are 0.03 mu g/L and 0.34 mu g/L (S/N = 3) for lead(II) and cadmium(II), respectively. This easy-to-prepare and low-cost electrode was also successfully applied to real water sample analysis. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 342
页数:4
相关论文
共 50 条
  • [21] Bismuth-coated screen-printed electrodes for stripping voltammetric measurements of trace lead
    Wang, J
    Lu, JM
    Hocevar, SB
    Ogorevc, B
    ELECTROANALYSIS, 2001, 13 (01) : 13 - 16
  • [22] Disposable screen-printed bismuth electrode modified with multi-walled carbon nanotubes for electrochemical stripping measurements
    Shanghai Key Laboratory of Functional Materials Chemistry, Research Centre of Analysis, Test, East China University of Science and Technology, No. 130 Meilong Road, Shanghai 200237, China
    不详
    Anal. Sci., 12 (1237-1241):
  • [23] Disposable Screen-printed Bismuth Electrode Modified with Multi-walled Carbon Nanotubes for Electrochemical Stripping Measurements
    Xiangheng Niu
    Hongli Zhao
    Minbo Lan
    Analytical Sciences, 2011, 27 : 1237 - 1241
  • [24] Disposable Screen-printed Bismuth Electrode Modified with Multi-walled Carbon Nanotubes for Electrochemical Stripping Measurements
    Niu, Xiangheng
    Zhao, Hongli
    Lan, Minbo
    ANALYTICAL SCIENCES, 2011, 27 (12) : 1237 - 1241
  • [25] Rapid and Easy Detection of Deoxynivalenol on a Bismuth Oxide Screen-printed Electrode
    Maria-Hormigos, Roberto
    Jesus Gismera, Maria
    Teresa Sevilla, Maria
    Rumbero, Angel
    Procopio, Jesus R.
    ELECTROANALYSIS, 2017, 29 (01) : 60 - 66
  • [26] Bismuth nanoparticles decorated graphenated carbon nanotubes modified screen-printed electrode for mercury detection
    Jeromiyas, Nithiya
    Elaiyappillai, Elanthamilan
    Kumar, Annamalai Senthil
    Huang, Sheng-Tung
    Mani, Veerappan
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2019, 95 : 466 - 474
  • [27] Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry
    Honeychurch, KC
    Hart, JP
    Cowell, DC
    Arrigan, DWM
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (03) : 642 - 652
  • [28] Uric Acid Determination by Adsorptive Stripping Voltammetry on Multiwall Carbon Nanotubes Based Screen-Printed Electrodes
    Fanjul-Bolado, Pablo
    Hernandez Santos, David
    Macho Montoya, Virgilio
    Costa-Garcia, Agustin
    ELECTROANALYSIS, 2015, 27 (05) : 1276 - 1281
  • [29] Simple and Sensitive Determination of Sibutramine in Slimming Tea Beverages Using a Carbon Screen-printed Electrode with Adsorptive Stripping Voltammetry
    Lima, Amanda B.
    dos Santos, Wallans T. P.
    Compton, Richard G.
    ELECTROANALYSIS, 2019, 31 (05) : 975 - 980
  • [30] Discrimination of Beers by Cyclic Voltammetry Using a Single Carbon Screen-Printed Electrode
    Rosello, Adam
    Serrano, Nuria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    ELECTROANALYSIS, 2021, 33 (04) : 864 - 872