The role of the ohmic contact on the efficiency of gallium arsenide radiation detectors

被引:3
|
作者
Castaldini, A
Cavallini, A
Polenta, L
Canali, C
delPapa, C
Nava, F
机构
[1] INFM,BOLOGNA,ITALY
[2] UNIV BOLOGNA,BOLOGNA,ITALY
[3] UNIV MODENA,DEPT ENGN SCI,I-41100 MODENA,ITALY
[4] UNIV UDINE,DEPT PHYS,I-33100 UDINE,ITALY
[5] UNIV MODENA,DEPT PHYS,I-41100 MODENA,ITALY
关键词
D O I
10.1016/S0168-9002(96)01263-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
It has recently been found that in gallium arsenide radiation detectors injecting ohmic contacts impede charge collection efficiency to get 100%, since breakdown occurs as soon as the electric field reaches the contact itself. In the present contribution, this phenomenon is investigated by comparing two sets of ohmic contacts realized by different technological procedures. While the overall defective state results to be nearly the same for both contacts, their performance significantly differs. Deep level junction spectroscopy shows that the defects are the same in both sets whilst there is much difference in density between a few of them.
引用
收藏
页码:417 / 420
页数:4
相关论文
共 50 条
  • [21] Gallium arsenide for vertex detectors
    DAuria, S
    Bates, R
    DaVia, C
    delPapa, C
    Gowdy, S
    OShea, V
    Raine, C
    Smith, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 386 (01): : 177 - 185
  • [22] Measurements of the quantum efficiency and depletion depth in gallium-arsenide detectors
    Erd, C
    Owens, A
    Brammertz, G
    Lumb, D
    Bavdaz, M
    Peacock, A
    Nenonen, S
    Andersson, H
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 386 - 393
  • [23] Quantum-Sensitive Ionizing Radiation Detectors Compensated by Gallium Arsenide
    O. P. Tolbanov
    Russian Physics Journal, 2003, 46 (8) : 800 - 810
  • [24] BAND BENDING IN GALLIUM-ARSENIDE DUE TO FORMATION OF AN OHMIC CONTACT (OPTICAL INVESTIGATION)
    BERKOVITS, VL
    LVOVA, TV
    KHASIEVA, RV
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1990, 24 (06): : 650 - 653
  • [25] OHMIC CONTACTS TO GALLIUM ARSENIDE SINGLE CRYSTALS
    SANDULOV.AV
    VARSHAVA, SS
    SCHERBAI, KS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (01): : 260 - &
  • [26] Use of epitaxial gallium arsenide in detectors
    V. M. Zaletin
    Yu. V. Tuzov
    V. F. Dvoryankin
    A. A. Sokolovskii
    Atomic Energy, 2007, 103 : 901 - 905
  • [27] Use of epitaxial gallium arsenide in detectors
    Zaletin, V. M.
    Tuzov, Yu. V.
    Dvoryankin, V. F.
    Sokolovskii, A. A.
    ATOMIC ENERGY, 2007, 103 (05) : 901 - 905
  • [28] Characteristics of nuclear radiation detectors based on semi-insulating gallium arsenide
    E. M. Verbitskaya
    V. K. Eremin
    A. M. Ivanov
    N. B. Strokan
    V. I. Vasil'ev
    V. N. Gavrin
    E. P. Veretenkin
    Yu. P. Kozlova
    V. B. Kulikov
    A. V. Markov
    A. Ya. Polyakov
    Semiconductors, 2004, 38 : 472 - 479
  • [29] Characteristics of nuclear radiation detectors based on semi-insulating gallium arsenide
    Verbitskaya, EM
    Eremin, VK
    Ivanov, AM
    Strokan, NB
    Vasil'ev, VI
    Gavrin, VN
    Veretenkin, EP
    Kozlova, YP
    Kulikov, VB
    Markov, AV
    Polyakov, AY
    SEMICONDUCTORS, 2004, 38 (04) : 472 - 479
  • [30] Gallium arsenide structures with deep centers and ionized radiation detectors based on them
    Khludkov S.S.
    Tolbanov O.P.
    Budnitskii D.L.
    Russian Physics Journal, 1998, 41 (8) : 768 - 772