Comparison study between static and dynamic responses of optical fiber weight in motion sensor

被引:2
|
作者
Hanto, D. [1 ]
Ula, R. K. [1 ]
Setiono, A. [1 ]
Puranto, P. [1 ]
Adinanta, H. [1 ]
Waluyo, T. B. [1 ]
Widiyatmoko, B. [1 ]
机构
[1] Indonesian Inst Sci, Res Ctr Phys, South Tangerang, Indonesia
关键词
D O I
10.1088/1742-6596/817/1/012041
中图分类号
O59 [应用物理学];
学科分类号
摘要
This research investigates responses of Optical Fiber Weight in Motion (WIM) sensors when static and dynamic weighing vehicle are applied. The vehicle used in the experiment was a replica of Mitsubishi FE 71 with weight of 23.01 kg. The WIM measurement system consisted of LED 1310 nm, optical fiber based WIM sensor, transimpedance amplified photodetector Ge PDA50 from Thorlabs, data acquisition DT translation 9816 S, speed sensors, and software program for WIM Evaluation. Static weighing was performed when the vehicle stopped. Besides performing static weighing on WIM sensor, measurement was also conducted on Kenko scale as validation. Meanwhile, measurement of dynamic weight was only conducted when the vehicle moved at a constant speed of about 1 km/h through WIM sensor. Experimental results showed two curves corresponded to the front axle load and the rear axle load. During static weighing, both WIM sensor and Kenko scales indicated similar output, which were flat curves. On the other hand, during dynamic weighing, WIM sensor had different output that was a pulse response. This preliminary study resulted in changes of amplitude and output shape. Unlike static weighing, moving vehicles contributed to the output of WIM sensor.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] COMPARISON OF HEMODYNAMIC-RESPONSES TO STATIC AND DYNAMIC EXERCISE
    BEZUCKA, G
    LENSER, M
    NAGLE, F
    HANSON, P
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1981, 13 (02): : 130 - 130
  • [22] COMPARISON OF HEMODYNAMIC-RESPONSES TO STATIC AND DYNAMIC EXERCISE
    BEZUCHA, GR
    LENSER, MC
    HANSON, PG
    NAGLE, FJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (06) : 1589 - 1593
  • [23] Competition between static and dynamic organisations in apparent motion
    Gepshtein, S.
    Kubovy, M.
    PERCEPTION, 1999, 28 : 43 - 44
  • [24] On the static and dynamic selectivity study of a sodium sensor
    Attari, M
    Fabry, P
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (04) : 732 - 735
  • [25] Optical Fiber Based Dynamic Displacement Measurement Sensor Using Polymer optical Fiber
    Ghaffar, Abdul
    Ali, Sikandar
    Zhang, HuiXin
    Hou, Yulong
    Liu, Wenyi
    Khan, Saeed Ahmed
    2019 2ND INTERNATIONAL CONFERENCE ON COMPUTING, MATHEMATICS AND ENGINEERING TECHNOLOGIES (ICOMET), 2019,
  • [26] Development of a Weight-in-Motion Measurement System with an Optical Sensor
    Janota, Ales
    Simak, Vojtech
    Hrbcek, Jozef
    SMART SOLUTIONS IN TODAY'S TRANSPORT, 2017, 715 : 234 - 247
  • [27] Comparison study of elasto plastic behavior on static and dynamic responses for plane lattice structures
    Taniguchi Y.
    Tokuda K.
    Journal of Structural and Construction Engineering, 2016, 81 (723): : 859 - 869
  • [28] Optical fiber reflectometry detecting static and dynamic Rayleigh spectra
    Zhang, Chao
    Ito, Fumihiko
    Yoshimura, Yuichi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (10)
  • [29] Static and Dynamic Structural Monitoring Based on Optical Fiber Sensors
    Antunes, Paulo
    Lima, Hugo
    Varum, Humberto
    Andre, Paulo
    2010 12TH INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS (ICTON), 2011,
  • [30] OPTICAL-FIBER SENSOR ARRAY FOR DYNAMIC VARIABLES
    NIEWISCH, J
    BARTELT, H
    SENSORS AND ACTUATORS A-PHYSICAL, 1994, 42 (1-3) : 562 - 566