Three-dimensional artifact induced by projection weighting and misalignment

被引:16
|
作者
Hsieh, J [1 ]
机构
[1] GE, Med Syst, Appl Sci Lab, Milwaukee, WI 53201 USA
关键词
computed tomography; isocenter misalignment; projection weights; three-dimensional and multiplanar reformatted images;
D O I
10.1109/42.768846
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In recent years, the use of computer graphic techniques to produce three-dimensional (3-D) and reformatted images from a set of axial computed tomography (CT) images has gained significant interest. In most cases, the CT images are generated with the projection data set weighted prior to reconstruction, to combat motion artifacts, data inconsistency, or redundant data samples, In this paper, we investigate the potential bias introduced to the reconstruction as a result of the interaction of the projection weights and the isocenter misalignment (ISM). We demonstrate that when the weights applied to the conjugate rays are significantly different, bias will result which favors the sample with a higher weight, Although the error is not easily detected in axial CT images, it can be quite visible in 3-D or multiplanar reformatted (MPR) images. In this paper, we first present a theoretical framework to analyze and predict the bias, The theoretical prediction is validated by both computer simulations and phantom experiments, Several schemes to combat this artifact are subsequently presented; and their effectiveness is demonstrated.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [31] Dynamic (de)focused projection for three-dimensional reconstruction
    Lertrusdachakul, Intuon
    Fougerolle, Yohan D.
    Laligant, Olivier
    OPTICAL ENGINEERING, 2011, 50 (11)
  • [32] Three-dimensional profilometry by symmetrical fringes projection technique
    Harizanova, Jana
    Sainov, Ventseslav
    OPTICS AND LASERS IN ENGINEERING, 2006, 44 (12) : 1270 - 1282
  • [33] Image distortion correction for lenticula misalignment in three-dimensional lenticular displays
    Lee, YG
    Ra, JB
    OPTICAL ENGINEERING, 2006, 45 (01)
  • [34] Three-dimensional spatial compounding of ultrasound scans with weighting by incidence angle
    Leotta, DF
    Martin, RW
    ULTRASONIC IMAGING, 2000, 22 (01) : 1 - 19
  • [35] The simulation and application of three-dimensional electrostatic weighting field in MRPC detector
    Yu, Y.
    Han, D.
    Wang, Y.
    Wang, F.
    Chen, X.
    Lyu, P.
    Guo, B.
    Shen, C.
    Zhang, Q.
    Li, Y.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [36] Three-dimensional distribution mass weighting for noninverted convection skew upwinding
    Ogedengbe, EOB
    Naterer, GF
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2004, 18 (04) : 502 - 510
  • [37] Three-dimensional spatial compounding of ultrasound scans with incidence angle weighting
    Leotta, DF
    Martin, RW
    1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1605 - 1608
  • [38] Thermophoretic transport for a three-dimensional reacting flow impinging on a disk with burner misalignment
    Univ of California at Berkeley, Berkeley, United States
    J Mater Process Manuf Sci, 3 (217-242):
  • [39] Macro-photogrammetry as a tool for the accurate measurement of three-dimensional misalignment in welding
    Rodriguez-Martin, M.
    Rodriguez-Gonzalvez, P.
    Laguela, S.
    Gonzalez-Aguilera, D.
    AUTOMATION IN CONSTRUCTION, 2016, 71 : 189 - 197
  • [40] A three-dimensional solder shape model incorporating top pad inclination and misalignment
    Rayasam, Mahidhar
    Subbarayan, Ganesh
    JOURNAL OF ELECTRONIC PACKAGING, 2006, 128 (03) : 291 - 293