Performance Evaluation of External Light Shelves by Applying a Prism Sheet

被引:16
|
作者
Lee, Heangwoo [1 ]
Seo, Janghoo [2 ]
机构
[1] Sangmyung Univ, Coll Design, Cheonan Si 31066, Chungcheongnam, South Korea
[2] Kookmin Univ, Sch Architecture, Seoul 02707, South Korea
基金
新加坡国家研究基金会;
关键词
external light shelf; prism sheet; performance evaluation; energy saving; VENTILATION; INTEGRATION; LOUVERS; DESIGN; BLINDS; SYSTEM;
D O I
10.3390/en13184618
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To address the increased use of lighting energy in the building sector, research on the use of light shelves has been increasing. Previous studies have focused on applying operating techniques to improve daylighting performance, which reduces the economic efficiency of light shelves and the building energy savings. This study proposes the use of prism sheets to improve the performance of light shelves, a concept which was validated by evaluating the performance related to saving building energy and improving indoor light uniformity through a full-scale testbed. This study used an external light shelf with no prism sheet, a window with a prism sheet applied, and a window with both an external light shelf and prism sheet applied as Case 1, Case 2, and Case 3, respectively, and analyzed the illuminance distribution and lighting energy consumption required to maintain the optimal indoor illumination for each case. This study also derived the optimal specifications for each case to save building energy and considered the flow of natural light to analyze the performance evaluation results. The main findings are as follows: (1) the optimal specifications to improve daylighting performance were derived for Case 1, requiring the application of operating techniques; (2) Case 2 was not suitable for saving energy and improving light uniformity when compared to Case 1; and (3) Case 3 was effective in saving building energy. In Case 3, even when the light shelf was fixed at 20 degrees without moving, it saved building energy and improved light uniformity compared to Case 1. However, the prism sheet in Case 3 should be detached during winter to maximize building energy savings.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] AN EVALUATION OF THE EFFECTS OF FILLED BASESTOCK ON COATED SHEET PERFORMANCE
    DAHLQUIST, RW
    WELCH, LJ
    HARDY, RE
    TAPPI JOURNAL, 1990, 73 (12): : 151 - 157
  • [32] Performance evaluation of a large rotational single sheet tester
    Nencib, N.
    Kedous-Lebouc, A.
    Cornut, B.
    Journal of Magnetism and Magnetic Materials, 1996, 160 : 174 - 176
  • [33] Evaluation of Spatial Characteristics of Corroded Situations in Service Steel Sheet Piles by Applying Geostatistics
    Hagiwara T.
    Yokobori S.
    Shimamoto Y.
    Suzuki T.
    Zairyo/Journal of the Society of Materials Science, Japan, 2023, 72 (03) : 188 - 195
  • [34] Deposition of Protective Layer on Stealth Sheet and Evaluation of the Protected Sheet's Mechanical Performance
    So, Sang Yeon
    Hahn, Jae Won
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2023, 34 (05) : 185 - 191
  • [35] Postgraduate Training Performance Evaluation Applying Weighting and Comprehensive Fuzzy Evaluation Methods
    Wang, Mei
    Zhang, Zeng
    Xu, Mi
    INTERNATIONAL JOURNAL OF EMERGING TECHNOLOGIES IN LEARNING, 2021, 16 (01): : 124 - 133
  • [36] Energy and Daylighting Evaluation of Integrated Semitransparent Photovoltaic Windows with Internal Light Shelves in Open-Office Buildings
    Mesloub, Abdelhakim
    Ghosh, Artira
    Albaqawy, Ghazy Abdullah
    Noaime, Emad
    Alsolami, Badr M.
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [38] Improvement of light-shelf performance through the use of a diffusion sheet
    Lee, Heangwoo
    Seo, Janghoo
    Kim, Suktae
    BUILDING AND ENVIRONMENT, 2018, 144 : 248 - 258
  • [39] Assessing the imaging performance of light sheet microscopies in highly scattering tissues
    Glaser, A. K.
    Wang, Y.
    Liu, J. T. C.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (02): : 454 - 466
  • [40] Impact of mismatched and misaligned laser light sheet profiles on PIV performance
    Grayson, K.
    de Silva, C. M.
    Hutchins, N.
    Marusic, I.
    EXPERIMENTS IN FLUIDS, 2018, 59 (01)