Final report: international comparison APMP.QM-S7 methane in nitrogen at 2000 μmol/mol

被引:4
|
作者
Kim, Byungmoon [1 ]
Bae, Hyounkil [1 ]
Lee, Sangil [1 ]
Oh, Sanghyub [1 ]
Lin, Tsai-Yin [2 ]
Huang, Chiug-Kun [2 ]
Sinweeruthai, Ratirat [3 ]
Rattanasombat, Soponrat [3 ]
Laongsri, Bunthoon [3 ]
Wongjuk, Arnuttachai [3 ]
Li, Hou
Hui, Liu
Keat, Teo Beng
Mogale, David
Johri, Prabha
Tarhan, Tanil
Engin, Erinc
机构
[1] KRISS, Ctr Gas Anal, 267 Gajeong Ro, Daejeon 305340, South Korea
[2] Ind Technol Res Inst, Ctr Measurement Stand, Hsinchu 30011, Taiwan
[3] Natl Inst Metrol Thailand, Pathum Thani 12120, Thailand
关键词
D O I
10.1088/0026-1394/52/1A/08013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Methane is one of the major greenhouse gases that affect climate change. To mitigate anthropogenic CH4 emissions effectively, it is necessary to measure and monitor CH4 emissions from fossil fuel combustion. Therefore, it is important for NMIs to have the capability of an accurate CH4 emissions measurement. The first key comparison on methane in nitrogen or air is the key comparison of CCQM-K82 (ambient level methane in air). As a supplementary comparison, the purpose of this comparison is to cover a concentration level that is not covered by previous key comparisons: this report describes the results of a supplementary comparison for methane in nitrogen at 2000 mu mol/mol. Results from all participants, except two, agree well within their associated uncertainties.
引用
收藏
页数:1
相关论文
共 50 条
  • [41] Final report on supplementary comparison on step heights standards (APMP.L-S7)
    Sharma, Rina
    Moona, Girija
    Tonmueanwai, Anusorn
    Buajarern, Jariya
    Wang Shihua
    Matus, Michael
    Doi, Takuma
    Sugawara, Kentaro
    METROLOGIA, 2021, 58 (1A)
  • [43] Final report on International Key Comparison COOMET.QM-K1: Carbon monoxide in nitrogen
    Konopelko, L A
    Kustikov, Y A
    Gromova, E V
    Rozhnov, M S
    Ananyin, V N
    Kluchits, A S
    Heine, H-J
    METROLOGIA, 2010, 47
  • [44] Final report of the pilot study CCQM-P110-B1: A comparison of nitrogen dioxide (NO2) in nitrogen standards at 10 μmol/mol by Fourier Transform Infrared Spectroscopy (FT-IR)
    Flores, Edgar
    Idrees, Faraz
    Moussay, Philippe
    Viallon, Joele
    Wielgosz, Robert
    Fernandez, Teresa
    Rojo, Andres
    Ramirez, Sergio
    Aoki, Nobuyuki
    Kato, Kenji
    Jeongsoon, Lee
    Moon, Dongmin
    Kim, Jin-Seog
    Harling, A.
    Milton, M.
    Smeulders, Damian
    Guenther, Franklin R.
    Gameson, Lyn
    Botha, Angelique
    Tshilongo, James
    Ntsasa, Napo Godwill
    Valkova, Miroslava
    Konopelko, Leonid A.
    Kustikov, Yury A.
    Ballandovich, Vladimir S.
    Gromova, Elena V.
    Tuma, Dirk
    Kohl, Anka
    Schulz, Gert
    METROLOGIA, 2012, 49
  • [45] Final report on APMP.QM-K18.2016 key comparison on pH measurement of carbonate buffer
    Asakai, Toshiaki
    Maksimov, Igor
    Onuma, Sachiko
    Bastkowski, Frank
    Sander, Beatrice
    Aparicio, Jose Luis Ortiz
    Manzano, Judith Velina Lara
    Lo, Samuel M. F.
    Poon, Desmond K. F.
    Delgado, Mabel
    Avendano, Paola
    Amaya, Ronald Cristancho
    Quezada, Henry Torres
    Gonzaga, Fabiano Barbieri
    Pardellas, Leonardo da Silva
    Dias, S. D. I.
    Gunawardana, D.
    Xiu Hongyu
    Bing, Wu
    Tangpaisarnkul, Nongluck
    Rodruangthum, Patumporn
    Gavrilkin, Vladimir V.
    Petrenko, Anton V.
    Prokunin, Sergey
    Vengina, Darya
    Dobrovolskiy, Vladimir
    METROLOGIA, 2021, 58 (1A)
  • [46] CCQM-K121-Monoterpenes in Nitrogen at 2.5 nmol mol-1 Final Report
    Liaskos, Christina
    Rhoderick, George
    Hodges, Joseph
    Possolo, Antonio
    Goodman, Cassie
    Kim, Yong Doo
    Kim, Dal Ho
    Lee, Sangil
    Allen, Nicholas
    Corbel, Marivon
    Worton, David
    Brown, Richard
    Brewer, Paul
    METROLOGIA, 2018, 55
  • [48] Final report of the APMP water flow supplementary comparison (APMP.M.FF-S1)
    Chun S.
    Furuichi N.
    Metrologia, 59 (1A):
  • [49] APMP Supplementary Comparison APMP.L-S3 Calibration of gauge blocks by mechanical comparison Final Report
    Drijarkara, Praba
    Kang, Chu-Shik
    METROLOGIA, 2012, 49
  • [50] Report on APMP Supplementary Comparison High precision roundness measurement APMP.L-S4 Final report
    Buajarern, J.
    Naoi, K.
    Baker, A.
    Zi, X.
    Tsai, C. L.
    Eom, T. B.
    Tan, S. L.
    Kruger, O.
    METROLOGIA, 2016, 53