Experimental iodine-125 seed irradiation of intracerebral brain tumors in nude mice

被引:11
|
作者
Verhoeff, Joost J. C. [2 ]
Stalpers, Lukas J. A. [2 ]
Coumou, Annet W. [1 ]
Koedooder, Kees [2 ]
Lavini, Cristina [3 ]
Van Noorden, Cornelis J. F. [4 ]
Haveman, Jaap [2 ]
Vandertop, William P. [1 ]
van Furth, Wouter R. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Neurosurg, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiat Oncol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Cell Biol & Histol, NL-1105 AZ Amsterdam, Netherlands
关键词
D O I
10.1186/1748-717X-2-38
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: High-dose radiotherapy is standard treatment for patients with brain cancer. However, in preclinical research external beam radiotherapy is limited to heterotopic murine models-high-dose radiotherapy to the murine head is fatal due to radiation toxicity. Therefore, we developed a stereotactic brachytherapy mouse model for high-dose focal irradiation of experimental intracerebral (orthotopic) brain tumors. Methods: Twenty-one nude mice received a hollow guide-screw implanted in the skull. After three weeks, 5 x 10(5) U251-NG2 human glioblastoma cells were injected. Five days later, a 2 mCi iodine-125 brachytherapy seed was inserted through the guide-screw in 11 randomly selected mice; 10 mice received a sham seed. Mice were euthanized when severe neurological or physical symptoms occurred. The cumulative irradiation dose 5 mm below the active iodine-125 seeds was 23.0 Gy after 13 weeks (BEDtumor = 30.6 Gy). Results: In the sham group, 9/10 animals (90%) showed signs of lethal tumor progression within 6 weeks. In the experimental group, 2/11 mice (18%) died of tumor progression within 13 weeks. Acute side effects in terms of weight loss or neurological symptoms were not observed in the irradiated animals. Conclusion: The intracerebral implantation of an iodine-125 brachytherapy seed through a stereotactic guide-screw in the skull of mice with implanted brain tumors resulted in a significantly prolonged survival, caused by high-dose irradiation of the brain tumor that is biologically comparable to high-dose fractionated radiotherapy-without fatal irradiation toxicity. This is an excellent mouse model for testing orthotopic brain tumor therapies in combination with radiation therapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Experimental iodine-125 seed irradiation of intracerebral brain tumors in nude mice
    Joost JC Verhoeff
    Lukas JA Stalpers
    Annet W Coumou
    Kees Koedooder
    Cristina Lavini
    Cornelis JF Van Noorden
    Jaap Haveman
    William P Vandertop
    Wouter R van Furth
    Radiation Oncology, 2
  • [2] Iodine-125 seed implantation in the treatment of malignant tumors
    Pan Hu
    Jianwen Huang
    Yanling Zhang
    Huanqing Guo
    Guanyu Chen
    Fujun Zhang
    Journal of Interventional Medicine, 2023, 6 (03) : 111 - 115
  • [3] Permanent Iodine-125 Seed Implantation for the Treatment of Nonresectable Retroperitoneal Malignant Tumors
    Li, Qingchun
    Tian, Yuan
    Yang, Dongyan
    Liang, Yun
    Cheng, Xianbin
    Gai, Baodong
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [4] Preparation of iodine-125 seed Part I
    Chunfu Zhang
    Yongxian Wang
    Haibin Tian
    Duan Zhiyin
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 161 - 163
  • [5] Stereotactic iodine-125 brachytherapy for brain tumors: temporary versus permanent implantation
    Ruge, Maximilian I.
    Kickingereder, Philipp
    Grau, Stefan
    Treuer, Harald
    Sturm, Volker
    Voges, Juergen
    RADIATION ONCOLOGY, 2012, 7
  • [6] Stereotactic iodine-125 brachytherapy for brain tumors: temporary versus permanent implantation
    Maximilian I Ruge
    Philipp Kickingereder
    Stefan Grau
    Harald Treuer
    Volker Sturm
    Juergen Voges
    Radiation Oncology, 7
  • [7] Mass Production of Source Core for Iodine-125 Seed
    Lee, Jin Hee
    Park, Ul Jae
    Son, Kwang Jae
    Choi, Kang Hyuk
    Yu, Kook Hyun
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (07): : 2172 - 2174
  • [8] Preparation of the radioactive source core of iodine-125 seed
    He Jiaheng
    Jiang Lin
    Li Xingliang
    Zhong Wenbin
    Wang Jing
    Ma Zongping
    Jian Yuan
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (04) : 231 - 234
  • [9] Calibration Seed Sampling for Iodine-125 Prostate Brachytherapy
    Crowe, Scott
    Kairn, Tanya
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 459 - 462
  • [10] Seed-less iodine-125 ophthalmic applicator
    Puchalska, I
    Mielcarski, M
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (01) : 15 - 20