Preparation of iodine-125 seed Part I

被引:0
|
作者
Chunfu Zhang
Yongxian Wang
Haibin Tian
Duan Zhiyin
机构
[1] Academia Sinica Shanghai,Institute of Nuclear Research
关键词
Physical Chemistry; Inorganic Chemistry; Iodine; Preparation Method; Valuable Data;
D O I
暂无
中图分类号
学科分类号
摘要
We studied the preparation method of 125I seeds and found that silver was a good carrier body for 125I and the ion-exchange technique was simple and effective for the preparation. Carrier iodine was critical for dose uniformity of the seeds and the minimal pH value for the reaction was 6.5. This paper provided valuable data for the development and preparation of 125I seed.
引用
收藏
页码:161 / 163
页数:2
相关论文
共 50 条
  • [1] Preparation of iodine-125 seed - Part I: Iodination of the silver rod
    Zhang, CF
    Wang, YX
    Tian, HB
    Duan, ZY
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (01) : 161 - 163
  • [2] Preparation of the radioactive source core of iodine-125 seed
    He Jiaheng
    Jiang Lin
    Li Xingliang
    Zhong Wenbin
    Wang Jing
    Ma Zongping
    Jian Yuan
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (04) : 231 - 234
  • [3] Preparation of the radioactive source core of iodine-125 seed
    HE Jiaheng JIANG Lin LI Xingliang ZHONG Wenbin WANG Jing MA Zongping JIAN Yuan Institute of Nuclear Physics and Chemistry
    Nuclear Science and Techniques, 2009, 20 (04) : 231 - 234
  • [4] An approach to the preparation of iodine-125 seed-type sources
    Cieszykowska, I
    Piasecki, A
    Mielcarski, M
    NUKLEONIKA, 2005, 50 (01) : 17 - 22
  • [5] Mass Production of Source Core for Iodine-125 Seed
    Lee, Jin Hee
    Park, Ul Jae
    Son, Kwang Jae
    Choi, Kang Hyuk
    Yu, Kook Hyun
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (07): : 2172 - 2174
  • [6] Iodine-125 seed implantation in the treatment of malignant tumors
    Pan Hu
    Jianwen Huang
    Yanling Zhang
    Huanqing Guo
    Guanyu Chen
    Fujun Zhang
    Journal of Interventional Medicine, 2023, 6 (03) : 111 - 115
  • [7] Calibration Seed Sampling for Iodine-125 Prostate Brachytherapy
    Crowe, Scott
    Kairn, Tanya
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 459 - 462
  • [8] Seed-less iodine-125 ophthalmic applicator
    Puchalska, I
    Mielcarski, M
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (01) : 15 - 20
  • [9] Iodine-125 seed prostate brachytherapy: seed prediction and class solutions
    Lau, Y. G. J.
    Al-Qaisieh, B.
    Wright, G.
    Brearley, E.
    Mason, J.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S334 - S334
  • [10] Clinical efficacy of iodine-125 (125I) seed implantation in patients with iodine-refractory differentiated thyroid cancer
    Su, Yingrui
    Wang, Jianlin
    Huang, Liqun
    Xie, Long
    Yu, Xiaopeng
    Zha, Jinshun
    AMERICAN JOURNAL OF CANCER RESEARCH, 2023, 13 (10): : 4794 - +