Acetabular All-Suture Anchor for Labral Repair: Incidence of Intraoperative Failure due to Pullout

被引:14
|
作者
Byrd, J. W. Thomas [1 ]
Jones, Kay S. [1 ]
Loring, Cynthia L. [2 ]
Sparks, Stephanie L. [2 ]
机构
[1] Nashville Sports Med Fdn, 2004 Hayes St,Suite 100, Nashville, TN 37203 USA
[2] St Thomas Surg Ctr Midtown, Nashville, TN USA
关键词
CLINICAL-OUTCOMES; HIP ARTHROSCOPY; INSERTION;
D O I
10.1016/j.arthro.2017.09.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To report on the incidence and features of intraoperative anchor pullout in a consecutive series of patients undergoing arthroscopic labral repair of the hip. Methods: Over an 18-month period, 434 consecutive cases underwent labral repair by a single surgeon with a particular anchor system. The following data were recorded: (1) age and gender of all cases; (2) number of anchors used; (3) number of cases in which intraoperative anchor failure occurred; (4) number of anchors that failed; and (5) age and gender of those cases in which anchor failure occurred. Failures were reported for 3-month intervals. One patient underwent repair with an alternative anchor system during this time period and was excluded. Results: Mean age was 34.2 (14-71) years with 180 males and 254 females. A total of 2,007 anchors were used, averaging 4.6 per case (1-8). Thirty-three anchors pulled out among 30 patients, representing a 1.6% incidence among all anchors. Mean age among pullouts was 37.8 (17-54) years with 11 males and 19 females. There was no difference compared with patient population in which no anchor pulled: mean 33.9 (14-71) years (P = .085) with 169 males and 235 females (P = .578). Pullouts were evenly distributed over the 3-month intervals (4, 4, 6, 6, 5, 8). Pullout was mostly due to failure to securely imbed the anchor in bone. Only 2 were known to pull out in the presence of being securely seated in bone. Conclusions: These data support that the security of this particular all-suture anchor at implantation is exceptionally reliable for a single experienced surgeon, and there is no demonstrable learning curve.
引用
收藏
页码:1213 / 1216
页数:4
相关论文
共 50 条
  • [31] Analysis of glenoid inter-anchor distance with an all-suture anchor system
    Kramer, Jonathan D.
    Robinson, Sean
    Purviance, Connor
    Montgomery, William, III
    JOURNAL OF ORTHOPAEDICS, 2018, 15 (01) : 102 - 106
  • [32] Maximum load to failure and tensile displacement of an all-suture glenoid anchor compared with a screw-in glenoid anchor
    Dwyer, Tim
    Willett, Thomas L.
    Dold, Andrew P.
    Petrera, Massimo
    Wasserstein, David
    Whelan, Danny B.
    Theodoropoulos, John S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (02) : 357 - 364
  • [33] All-Suture Anchor Settling After Arthroscopic Repair of Small and Medium Rotator Cuff Tears
    Ro, Kyunghan
    Rhee, Sung-Min
    Kim, Jung Youn
    Kim, Myung Seo
    Kim, Jong Dae
    Lee, Hojin
    Rhee, Yong Girl
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (14): : 3483 - 3490
  • [34] Cyclic and Load to Failure Properties of All-Suture Anchors in Synthetic Acetabular and Glenoid Cancellous Bone
    Douglass, Nathan P.
    Behn, Anthony W.
    Safran, Marc R.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (05): : 977 - 985.e5
  • [35] Comparison of Clinical Outcomes and Computed Tomography Analysis for Tunnel Diameter After Arthroscopic Bankart Repair With the All-Suture Anchor and the Biodegradable Suture Anchor
    Lee, Jae-Hoo
    Park, In
    Hyun, Hwan-Sub
    Kim, Sang-Woo
    Shin, Sang-Jin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (05): : 1351 - 1358
  • [36] Subpectoral Biceps Tenodesis: All-Suture Anchor Onlay Technique
    Lacheta, Lucca
    Imhoff, Andreas B.
    Siebenlist, Sebastian
    Scheiderer, Bastian
    ARTHROSCOPY TECHNIQUES, 2020, 9 (05): : E651 - E655
  • [37] Trapeziectomy and All-Suture Anchor Suspensionplasty for Basal Joint Arthritis
    Roebke, Austin J.
    Julka, Abhishek
    TECHNIQUES IN ORTHOPAEDICS, 2022, 37 (01) : 62 - 64
  • [38] Subpectoral Biceps Tenodesis Using an All-Suture Knotless Anchor
    Moroski, Nathan
    Eskew, Joshua
    Cole, Austin
    ARTHROSCOPY TECHNIQUES, 2023, 12 (06): : e937 - e942
  • [39] Arthroscopic Hip Labral Repair With Knotless FiberTak Suture Anchor
    Nasra, Matthew
    Vasavada, Kinjal
    Yao, Kaisen
    Sugarman, Etan
    ARTHROSCOPY TECHNIQUES, 2024, 13 (07):
  • [40] Arthroscopic separate labral repair and capsular plication with a suture anchor
    Kim, Kyung Cheon
    Rhee, Kwang Jin
    Shin, Hyun Dae
    Kim, Young Mo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (05) : 535 - 538