A gamma-ray imaging camera for ambient radioactivity detection

被引:2
|
作者
Altomare, C. [1 ,2 ]
Di Venere, L. [1 ]
Fanchini, E. [3 ]
Giordano, F. [1 ,2 ]
Loparco, F. [1 ,2 ]
Morichi, M. [3 ]
Pantaleo, F. R. [1 ,2 ]
Spinelli, P. [1 ,2 ]
Swiderski, L. [4 ]
机构
[1] Ist Nazl Fis Nucl, Sez Bari, Bari, Italy
[2] Univ & Politecn Bari, Dipartimento Interateneo Fis, Bari, Italy
[3] CAEN Spa Viareggio, Viareggio, Italy
[4] Natl Ctr Nucl Res NCBJ, PL-05400 Otwock, Poland
关键词
Gamma camera; Gamma imaging; Scintillator CsI(Tl); Silicon Photomultiplier SiPM;
D O I
10.1016/j.nima.2020.164492
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this work is to design a camera for gamma-ray imaging based on the coded mask technique widely used in astrophysics. The camera proposed is a compact, lightweight instrument, ideal for real-time analysis, with a low power consumption. The proof of concept consist in 16 CsI(Tl) scintillators coupled to photo-multiplier tubes (PMTs) with a digital readout. The scintillators are arranged in a 4 x 4 matrix and packaged in a metallic frame. We used a 7 x 7 mask composed by transparent and opaque files to encode and decode a radioactive gamma-rays point source image through a reconstruction algorithm. The system was tested using gamma-ray radioactive sources placed at a fixed distance from the mask. The performance of the prototype camera in terms of energy and spatial resolution will be shown. An upgrade of this prototype will employ Silicon Photomultipliers (SiPMs) in place of the PMTs. A comparison of the two configurations will be also provided.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] MEASUREMENT OF LOW GAMMA-RAY WITH THE SCINTILLATION CAMERA
    KLOSE, E
    RITTER, EP
    ENDERT, G
    RADIOBIOLOGIA-RADIOTHERAPIA, 1979, 20 (06) : 826 - 826
  • [42] PERFORMANCE OF A COAXIAL GERMANIUM GAMMA-RAY CAMERA
    STRAUSS, MG
    SHERMAN, IS
    BRENNER, R
    LENKSZUS, FR
    JOURNAL OF NUCLEAR MEDICINE, 1974, 15 (12) : 1196 - 1200
  • [43] THE EFFECT OF GAMMA-RAY EXPOSURE ON CAMERA FILMS
    CORNEY, GM
    PHOTOGRAPHIC SCIENCE AND ENGINEERING, 1960, 4 (05): : 291 - 295
  • [44] THE EFFECT OF GAMMA-RAY EXPOSURES ON CAMERA FILMS
    CORNEY, GM
    PHOTOGRAPHIC SCIENCE AND ENGINEERING, 1959, 3 (05): : 250 - 250
  • [45] GAMMA-RAY ATTENUATION AND QUANTITATIVE GAMMA-CAMERA STUDIES
    TURNER, J
    RUTLAND, MD
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1988, 18 (03): : 509 - 509
  • [46] Gamma-ray tomography in fluidised beds using a gamma camera
    Bom, VR
    van Eijk, CWE
    Jonkers, G
    Por, PT
    van de Vorst, JGG
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 1998, 20 (04) : 178 - 185
  • [47] DETECTION OF GAMMA-RAY LINES
    PETERSON, LE
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1981, 301 (1462): : 669 - 669
  • [48] Gamma-ray tracking for high energy gamma-ray imaging in pixelated CdZnTe
    Shy, Daniel
    He, Zhong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [49] Experimental Results of the Gamma-Ray Imaging Capability With a Si/CdTe Semiconductor Compton Camera
    Takeda, Shin'ichiro
    Aono, Hiroyuki
    Okuyama, Sho
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Watanabe, Shin
    Kokubun, Motohide
    Takahashi, Tadayuki
    Nakazawa, Kazuhiro
    TajimaHiro, Hiroyasu
    Kawachi, Naoki
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 783 - 790
  • [50] Development of a prompt gamma-ray analysis combined with multiple gamma-ray detection
    Toh, Y
    Oshima, A
    Koizumi, A
    Osa, A
    Kimura, A
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2006, 819 : 603 - +