The diagnostic accuracy of single- and five-field fundus photography in diabetic retinopathy screening by primary care physicians

被引:20
|
作者
Srihatrai, Parinya [1 ]
Hlowchitsieng, Thanita [1 ]
机构
[1] Mahasarakham Univ, Suddhavej Hosp, Dept Ophthalmol, Fac Med, Mueang, Maha Sarakham, Thailand
关键词
Diabetic retinopathy; fundus camera; fundus photography; screening;
D O I
10.4103/ijo.IJO_657_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim is to evaluate the diagnostic accuracy of digital fundus photography in diabetic retinopathy (DR) screening at a single university hospital. Methods: This was a cross-sectional hospital-based study. One hundred and ninety-eight diabetic patients were recruited for comprehensive eye examination by two ophthalmologists. Five-field fundus photographs were taken with a digital, nonmydriatic fundus camera, and trained primary care physicians then graded the severity of DR present by single-field 45 degrees and five-field fundus photography. Sensitivity and specificity of DR grading were reported using the findings from the ophthalmologists' examinations as a gold standard. Results: When fundus photographs of the participants' 363 eyes were analyzed for the presence of DR, there was substantial agreement between the two primary care physicians, kappa = 0.6226 for single-field and 0.6939 for five-field photograph interpretation. The sensitivity and specificity of DR detection with single-field photographs were 70.7% (95% Confidence interval [CI]; 60.2%-79.7%) and 99.3% (95% CI; 97.4%-99.9%), respectively. Sensitivity and specificity for five-field photographs were 84.5% (95% CI; 75.8%-91.1%) and 98.6% (95% CI; 96.5%-99.6%), respectively. The receiver operating characteristic was 0.85 (0.80-0.90) for single-field photographs and 0.92 (0.88-0.95) for five-field photographs. Conclusion: The sensitivity and specificity of fundus photographs for DR detection by primary care physicians were acceptable. Single-and five-field digital fundus photography each represent a convenient screening tool with acceptable accuracy.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 50 条
  • [31] The sensitivity and specificity of single-field nonmydriatic monochromatic digital fundus photography with remote image interpretation for diabetic retinopathy screening: A comparison with ophthalmoscopy and standardized mydriatic color photography
    Lin, DY
    Blumenkranz, MS
    Brothers, RJ
    Grosvenor, DM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (02) : 204 - 213
  • [32] Diagnostic accuracy of non-mydriatic fundus camera for screening of diabetic retinopathy: A hospital based observational study in Pakistan
    Fahadullah, Muhammad
    Memon, Nasir Ahmed
    Salim, Sumaira
    Ahsan, Shahid
    Fahim, Muhammad Faisal
    Mumtaz, Seema Nigah
    Shaikh, Sikander Ali
    Memon, Muhammad Saleh
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2019, 69 (03) : 378 - 382
  • [33] Assessment of early diabetic retinopathy severity using ultra-widefield Clarus versus conventional five-field and ultra-widefield Optos fundus imaging
    Yuanyuan Xiao
    Handong Dan
    Xiaofeng Du
    Michel Michaelide
    Xiaodong Nie
    Wanxiao Wang
    Miao Zheng
    Dongdong Wang
    Zixu Huang
    Zongming Song
    Scientific Reports, 13 (1)
  • [34] Comparison of true-colour wide-field confocal scanner imaging with standard fundus photography for diabetic retinopathy screening
    Olvera-Barrios, Abraham
    Heeren, Tjebo F. C.
    Balaskas, Konstantinos
    Chambers, Ryan
    Bolter, Louis
    Tufail, Adnan
    Egan, Catherine
    Anderson, John
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (11) : 1579 - 1584
  • [35] Two-field photography can identify patients with vision-threatening diabetic retinopathy - A screening approach in the primary care setting
    Stellingwerf, C
    Hardus, PLLJ
    Hooymans, JMM
    DIABETES CARE, 2001, 24 (12) : 2086 - 2090
  • [36] Telemedicine for Diabetic Retinopathy Screening in an Urban, Insured Population Using Fundus Cameras in a Primary Care Office Setting
    Martinez, Jose Agustin
    Parikh, Pooja D.
    Wong, Robert W.
    Harper, Clio A.
    Dooner, James W.
    Levitan, Mark
    Nixon, Peter A.
    Young, Ryan C.
    Ghafoori, Shelley Day
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2019, 50 (11): : E274 - E277
  • [37] Assessment of early diabetic retinopathy severity using ultra-widefield Clarus versus conventional five-field and ultra-widefield Optos fundus imaging
    Xiao, Yuanyuan
    Dan, Handong
    Du, Xiaofeng
    Michaelide, Michel
    Nie, Xiaodong
    Wang, Wanxiao
    Zheng, Miao
    Wang, Dongdong
    Huang, Zixu
    Song, Zongming
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [38] Prevalence of diabetic retinopathy in an urban diabetic population based on a single-field nonnnydriatic digital fundus photographic screening modality
    Lin, DY
    Blumenkranz, MS
    Brothers, RJ
    Grosvenor, DM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U1263 - U1263
  • [39] Diagnostic accuracy and feasibility of artificial intelligence-based diabetic retinopathy screening in primary care settings: a real-world assessment
    Joseph, Sanil
    Shang, Xianwen
    Kiburg, Katerina
    Henwood, Jacqueline
    Zhu, Zhuoting
    Clark, Malcolm
    MacIsaac, Richard
    Ravilla, Thulasiraj D.
    van Wijngaarden, Peter
    He, Minguang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [40] Two-field non-mydriatic fundus photography for diabetic retinopathy screening: a protocol for a systematic review and meta-analysis
    Yu, Dongjing
    Dou, Xiaoyan
    Chen, Jiao
    Lu, Ying
    Ye, Baikang
    Wu, Xiaojun
    Wu, Zijing
    Li, Qi
    Tian, Xiaohe
    Zhou, Bo
    Deng, Ying
    Li, Wei
    Hu, Xinglin
    Mou, Lisha
    Pu, Zuhui
    BMJ OPEN, 2021, 11 (10):