A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery

被引:28
|
作者
Suh, Yelin [1 ,2 ]
Weiss, Elisabeth [2 ]
Zhong, Hualiang [2 ]
Fatyga, Mirek [2 ]
Siebers, Jeffrey V. [2 ]
Keall, Paul J. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA USA
关键词
lung cancer; IMRT; 4D CT; DMLC tracking;
D O I
10.1016/j.ijrobp.2008.04.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a deliverable four-dimensional (41)) intensity-modulated radiation therapy (IMRT) planning method for dynamic multileaf collimator (MLC) tumor tracking delivery. Methods and Materials: The deliverable 4D IMRT planning method involves aligning MLC leaf motion parallel to the major axis of target motion and translating MLC leaf positions by the difference in the target centroid position between respiratory phases of the 4D CT scan. This method ignores nonlinear respiratory motion and deformation. A three-dimensional (3D) optimal method whereby an IMRT plan on each respiratory phase of the 4D CT scan was independently optimized was used for comparison. For 12 lung cancer patient 4D CT scans, individual phase plans and deformable dose-summed 4D plans using the two methods were created and compared. Results: For each of the individual phase plans, the deliverable method yielded similar isodose distributions and dose-volume histograms. The deliverable and 3D optimal methods yielded statistically equivalent dose-volume metrics for both individual phase plans and 4D plans (p > 0.05 for all metrics compared). The deliverable method was affected by 4D CT artifacts in one case. Both methods were affected by high vector field variations from deformable registration. Conclusions: The deliverable method yielded similar dose distributions for each of the individual phase plans and statistically equivalent dosimetric values compared with the 3D optimal method, indicating that the deliverable method is dosimetrically robust to the variations of fractional time spent in respiratory phases on a given 4D CT scan. Nonlinear target motion and deformation did not cause significant dose discrepancies. (C) 2008 Elsevier Inc.
引用
收藏
页码:1526 / 1536
页数:11
相关论文
共 50 条
  • [1] FOUR-DIMENSIONAL INTENSITY-MODULATED RADIOTHERAPY PLANNING FOR DYNAMIC MULTILEAF COLLIMATOR TRACKING RADIOTHERAPY
    Liang, Yueqiang
    Xu, Hongbing
    Yao, Jonathan
    Li, Zhihui
    Chen, Wendy
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 266 - 274
  • [2] A modified method of planning and delivery for dynamic multileaf collimator intensity-modulated radiation therapy
    Dogan, N
    Leybovich, LB
    Sethi, A
    Krasin, M
    Emami, B
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01): : 241 - 245
  • [3] Planning Four-Dimensional Intensity-Modulated Arc Therapy for Tumor Tracking
    Niu, Y.
    Betzel, G.
    Yang, X.
    Gui, M.
    Parke, W.
    Yi, B.
    Yu, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Delivery of intensity-modulated treatments with dynamic multileaf collimator
    Boyer, AL
    Strait, JP
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 13 - 15
  • [5] Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method
    Gui, Minzhi
    Feng, Yuanming
    Yi, Byongyong
    Dhople, Anil Arvind
    Yu, Cedric
    [J]. MEDICAL PHYSICS, 2010, 37 (05) : 1966 - 1975
  • [6] Planning 4D intensity-modulated arc therapy for tumor tracking with a multileaf collimator
    Niu, Ying
    Betzel, Gregory T.
    Yang, Xiaocheng
    Gui, Minzhi
    Parke, William C.
    Yi, Byongyong
    Yu, Cedric X.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04): : 1480 - 1500
  • [7] Intensity-modulated radiation therapy using a multileaf collimator
    Webb, S
    [J]. RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 660 - 663
  • [8] Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods
    Chui, CS
    Chan, MF
    Yorke, E
    Spirou, S
    Ling, CC
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2441 - 2449
  • [9] Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator
    Dai, JR
    Zhu, YP
    [J]. MEDICAL PHYSICS, 2001, 28 (10) : 2113 - 2120
  • [10] Intensity-modulated radiation therapy with dynamic multileaf collimators
    Boyer, AL
    Yu, CX
    [J]. SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) : 48 - 59