PVC-based cobalt and manganese phthalocyanine coated graphite electrodes for determination of thiocyanate

被引:43
|
作者
Amini, MK [1 ]
Shahrokhian, S [1 ]
Tangestaninejad, S [1 ]
机构
[1] Univ Esfahan, Dept Chem, Esfahan 81744, Iran
关键词
potentiometry; ionophores; thiocyanate selective electrode; cobalt phthalocyanine; manganese phthalocyanine; PVC; graphite rods;
D O I
10.1080/00032719908543002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thiocyanate selective electrodes were prepared by incorporating cobalt and manganese phthalocyanines into plasticized ploy(vinyl chloride) membranes which were directly coated on the surface of graphite electrodes. A calibration plot with Nernstian slope for thiocyanate was observed over a linear range of five decades of concentration (1x10(-6)-1x10(-1) M). The electrode has a fast response time, very low detection limit (5x10(-7) M thiocyanate), is easy to prepare, and could be used for over a month. The proposed sensor revealed good selectivity for thiocyanate over several anions and could be used over a wide pH range. Applications of the electrode to the potentiometric titration of silver ion with thiocyanate and determination of thiocyanate in urine samples are reported.
引用
收藏
页码:2737 / 2750
页数:14
相关论文
共 50 条
  • [31] Determination of thiocyanate ions at nanolevel in real samples using coated graphite electrode based on synthesised macrocyclic Zn(II) complex
    Prerna Singh
    Ashok K. Singh
    Analytical and Bioanalytical Chemistry, 2011, 400 : 2261 - 2269
  • [32] Determination of thiocyanate ions at nanolevel in real samples using coated graphite electrode based on synthesised macrocyclic Zn(II) complex
    Singh, Prerna
    Singh, Ashok K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (07) : 2261 - 2269
  • [33] PVC membrane and coated graphite potentiometric sensors based on Et4todit for selective determination of samarium(III)
    Shamsipur, M
    Hosseini, M
    Alizadeh, K
    Talebpour, Z
    Mousavi, MF
    Ganjali, MR
    Arca, M
    Lippolis, V
    ANALYTICAL CHEMISTRY, 2003, 75 (21) : 5680 - 5686
  • [34] Azithromycin-molecularly imprinted polymer based on PVC membrane for Azithromycin determination in drugs using coated graphite electrode
    Abu-Dalo, Muna A.
    Nassory, Nabil S.
    Abdulla, Najwa I.
    Al-Mheidat, Ismaeel R.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 751 : 75 - 79
  • [35] Thiocyanate-selective PVC membrane electrodes based on organotin(IV) compounds as neutral carriers
    Li, ZQ
    Song, XP
    Yuan, R
    Ying, M
    Shen, GL
    Yu, RQ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1999, 20 (01): : 47 - 49
  • [36] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF THIOCYANATE AND SELENOCYANATE AT A COBALT PHTHALOCYANINE MODIFIED CARBON-PASTE ELECTRODE
    COOKEAS, EG
    EFSTATHIOU, CE
    ANALYST, 1994, 119 (07) : 1607 - 1612
  • [37] Thiocyanate-selective PVC Membrane Electrodes Based on Organotin(IV) Compounds as Neutral Carriers
    Li, Zhi-Qiang
    Song, Xiao-Ping
    Yuan, Ruo
    Ying, Min
    Shen, Guo-Li
    Yu, Ru-Qin
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 20 (01):
  • [38] NEW SILVER ION-SELECTIVE PVC MEMBRANE AND COATED-GRAPHITE ELECTRODES BASED ON A NOVEL CALIX[4]ARENE DERIVATIVE
    Erol, Sibel
    Ozel, Ayca Demirel
    Yilmaz, Mustafa
    Kilic, Esma
    REVIEWS IN ANALYTICAL CHEMISTRY, 2009, 28 (01) : 27 - 49
  • [39] Electrochemical determination of perchlorate ion by polymeric membrane and coated graphite electrodes based on zinc complexes of macrocyclic ligands
    Gupta, Vinod Kumar
    Singh, Ashok Kumar
    Singh, Prerna
    Upadhyay, Anjali
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 : 201 - 209
  • [40] Cobalt(II)-selective coated graphite PVC-membrane electrode based on a recently synthesized dibenzopyridino-substituted macrocyclic diamide
    Shamsipur, M
    Rouhani, S
    Poursaberi, T
    Ganjali, MR
    Sharghi, H
    Niknam, K
    ELECTROANALYSIS, 2002, 14 (11) : 729 - 735