Frequency-agile gyrotron for electron decoupling and pulsed dynamic nuclear polarization

被引:55
|
作者
Scott, Faith J. [1 ]
Saliba, Edward P. [1 ]
Albert, Brice J. [1 ]
Alaniva, Nicholas [1 ]
Sesti, Erika L. [1 ]
Gao, Chukun [1 ]
Golota, Natalie C. [1 ]
Choi, Eric J. [1 ]
Jagtap, Anil P. [2 ]
Wittmann, Johannes J. [3 ,4 ]
Eckardt, Michael [5 ,6 ]
Harneit, Wolfgang [5 ,6 ]
Corzilius, Bjorn [3 ,4 ]
Sigurdsson, Snorri Th. [2 ]
Barnes, Alexander B. [1 ]
机构
[1] Washington Univ, Dept Chem, One Brookings Dr, St Louis, MO 63130 USA
[2] Univ Iceland, Sci Inst, Dept Chem, Dunhaga 3, IS-107 Reykjavik, Iceland
[3] Goethe Univ Frankfurt, Inst Biophys Chem, Inst Phys & Theoret Chem, Max von Laue Str 7-9, D-60438 Frankfurt, Germany
[4] Goethe Univ Frankfurt, Ctr Biomol Magnet Resonance BMRZ, Max von Laue Str 7-9, D-60438 Frankfurt, Germany
[5] Johannes Gutenberg Univ Mainz, Inst Phys Chem, Duesbergweg 10-14, D-55099 Mainz, Germany
[6] Univ Osnabruck, Fachbereich Phys, Barbarastr 7, D-49076 Osnabruck, Germany
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Dynamic nuclear polarization; Electron decoupling; Gyrotron; Chirp pulses; Pulsed DNP; 250 GHZ GYROTRON; PARAMAGNETIC-RESONANCE; ADIABATIC PULSES; HIGH-POWER; NMR; MODULATION; DNP; TEMPERATURE; N-AT-C-60; INSTRUMENTATION;
D O I
10.1016/j.jmr.2018.02.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a frequency-agile gyrotron which can generate frequency-chirped microwave pulses. An arbitrary waveform generator (AWG) within the NMR spectrometer controls the microwave frequency, enabling synchronized pulsed control of both electron and nuclear spins. We demonstrate that the acceleration of emitted electrons, and thus the microwave frequency, can be quickly changed by varying the anode voltage. This strategy results in much faster frequency response than can be achieved by changing the potential of the electron emitter, and does not require a custom triode electron gun. The gyrotron frequency can be swept with a rate of 20 MHz/mu s over a 670 MHz bandwidth in a static magnetic field. We have already implemented time-domain electron decoupling with dynamic nuclear polarization (DNP) magic angle spinning (MAS) with this device. In this contribution, we show frequency-swept DNP enhancement profiles recorded without changing the NMR magnet or probe. The profile of endofullerenes exhibits a DNP profile with a <10 MHz linewidth, indicating that the device also has sufficient frequency stability, and therefore phase stability, to implement pulsed DNP mechanisms such as the frequency-swept solid effect. We describe schematics of the mechanical and vacuum construction of the device which includes a novel flanged sapphire window assembly. Finally, we discuss how commercially available continuous-wave gyrotrons can potentially be converted into similar frequency-agile high-power microwave sources. (C) 2018 Published by Elsevier Inc.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [11] Dynamic Distributed Pressure Measurement Using Frequency-Agile Fast BOTDA
    Qiu, Liqiang
    Zhou, Dengwang
    Wang, Ying
    Chu, Qi
    Zhu, Zongda
    Li, Tianfu
    Dong, Yongkang
    IEEE SENSORS JOURNAL, 2021, 21 (22) : 25743 - 25748
  • [12] Frequency swept microwaves for hyperfine decoupling and time domain dynamic nuclear polarization
    Hoff, Daniel E. M.
    Albert, Brice J.
    Saliba, Edward P.
    Scott, Faith J.
    Choi, Eric J.
    Mardini, Michael
    Barnes, Alexander B.
    SOLID STATE NUCLEAR MAGNETIC RESONANCE, 2015, 72 : 79 - 89
  • [13] Dynamic Nuclear Polarization with Electron Decoupling in Intact Human Cells and Cell Lysates
    Judge, Patrick T.
    Sesti, Erika L.
    Price, Lauren E.
    Albert, Brice J.
    Alaniva, Nicholas
    Saliba, Edward P.
    Halbritter, Thomas
    Sigurdsson, Snorri Th
    Kyei, George B.
    Barnes, Alexander B.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2020, 124 (12): : 2323 - 2330
  • [14] A Compact 395 GHz Gyrotron for Dynamic Nuclear Polarization
    Sirigiri, Jagadishwar R.
    Maly, Thorsten
    Tarricone, Lou
    2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
  • [15] Demonstration of a 263 GHz Gyrotron for Dynamic Nuclear Polarization
    Blank, M.
    Borchard, P.
    Cahalan, P.
    Cauffman, S.
    Felch, K.
    Rosay, M.
    Tometich, L.
    2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 172 - 172
  • [16] Dynamic distributed Brillouin sensing based on pump frequency-agile quadrupling modulation
    Bai, Xueqian
    Wang, Wenrui
    Zhou, Biying
    Hu, Jun
    Wang, Ruoqi
    Ye, Lingyun
    Song, Kaichen
    Optical Fiber Technology, 2024, 88
  • [17] First Tests of a 527 GHz Gyrotron for Dynamic Nuclear Polarization
    Felch, Kevin
    Blank, Monica
    Borchard, Philipp
    Cauffman, Stephen
    Rosay, Melanie
    Tometich, Leo
    2013 IEEE 14TH INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2013,
  • [18] Dynamic nuclear polarization in pulsed ENDOR experiments
    Kouskov, V
    Sloop, DJ
    Liu, SB
    Lin, TS
    JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) : 25 - 28
  • [19] High Frequency Dynamic Nuclear Polarization
    Ni, Qing Zhe
    Daviso, Eugenio
    Can, Thach V.
    Markhasin, Evgeny
    Jawla, Sudheer K.
    Swager, Timothy M.
    Temkin, Richard J.
    Herzfeld, Judith
    Griffin, Robert G.
    ACCOUNTS OF CHEMICAL RESEARCH, 2013, 46 (09) : 1933 - 1941
  • [20] Terahertz Gyrotron Used for Dynamic Nuclear-Polarization-Enhanced Nuclear Magnetic Resonance
    Song Tao
    Wang Wei
    Liu Diwei
    Liu Shenggang
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (06):