Metal Artifact Reduction Based on Beam Hardening Correction and Statistical Iterative Reconstruction for X-ray Computed Tomography

被引:7
|
作者
Zhang, Yanbo [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Shaanxi, Peoples R China
关键词
Computed tomography; metal artifacts; beam hardening; statistical reconstruction; IMAGE-RECONSTRUCTION; TRANSMISSION TOMOGRAPHY; CT; SIMULATION;
D O I
10.1117/12.2008176
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Metal artifact is a main cause to degrade CT image quality, but there is still no standard solution to this issue. The cause of introduction of metal artifacts is due to several physical effects, in which beam hardening and noise are two major factors. Accordingly, in this paper these two factors are alleviated by using beam hardening correction based on polynomial fitting and statistical iterative reconstruction based on Poisson log-likelihood approach. Unlike other metal artifact reduction (MAR) methods by using iterative image reconstruction from polychromatic projection dataset, the proposed method in this work does not require a priori knowledge about the X-ray spectrum and attenuations of the materials to be reconstructed. A conventional linear interpolation MAR algorithm and two MAR methods based on beam hardening correction are performed for comparison. Simulation results illustrate that the proposed method can suppress metal artifacts greatly and restore low contrast tissues well.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A stopping criterion for iterative reconstruction of X-ray computed tomography
    Yang, Yirong
    Liang, Kaichao
    Xing, Yuxiang
    Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2020, 11312
  • [32] A Stopping Criterion for iterative reconstruction of X-ray computed tomography
    Yang, Yirong
    Liang, Kaichao
    Xing, Yuxiang
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [33] Metal artifact correction for x-ray computed tomography using kV and selective MV imaging
    Wu, Meng
    Keil, Andreas
    Constantin, Dragos
    Star-Lack, Josh
    Zhu, Lei
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2014, 41 (12)
  • [34] X-ray beam hardening correction for measuring density in linear accelerator industrial computed tomography
    Zhou Ri-Feng
    Wang Jue
    Chen Wei-Min
    CHINESE PHYSICS C, 2009, 33 (07) : 599 - 602
  • [35] X-ray beam hardening correction for measuring density in linear accelerator industrial computed tomography
    周日峰
    王珏
    陈伟民
    中国物理C, 2009, 33 (07) : 599 - 602
  • [36] Novel methods for metal artifact reduction in x-ray tomography
    Cho, Seungryong
    Lee, Jung Ryun
    2018 INTERNATIONAL WORKSHOP ON ADVANCED IMAGE TECHNOLOGY (IWAIT), 2018,
  • [37] Image-based Metal Artifact Reduction in X-ray Computed Tomography utilizing Local Anatomical Similarity
    Dong, Xue
    Yang, Xiaofeng
    Rosenfield, Jonathan
    Elder, Eric
    Dhabaan, Anees
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [38] Fast iterative beam hardening correction based on frequency splitting in computed tomography
    Yang, Qiao
    Elter, Matthias
    Schasiepen, Ingo
    Maass, Nicole
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [39] Statistical image reconstruction for polyenergetic X-ray computed tomography
    Elbakri, IA
    Fessler, JA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) : 89 - 99
  • [40] X-ray attenuation models to account for beam hardening in computed tomography
    Yang, Q.
    Fullagar, W. K.
    Myers, G. R.
    Latham, S. J.
    Varslot, T.
    Sheppard, A. P.
    Kingston, A. M.