Study of incipient bearing damage monitoring in variable-speed drive systems

被引:0
|
作者
Romanenko, Aleksei [1 ]
Ahola, Jero [1 ]
Muetze, Annette [2 ]
Niskanen, Ville [1 ]
机构
[1] Lappeenranta Univ Technol, FI-53851 Lappeenranta, Finland
[2] Graz Univ Technol, A-8010 Graz, Austria
关键词
Measurements; Induction motor; Converter machine interactions; Diagnostics; Wireless sensors; CURRENTS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Inverter-induced high-frequency bearing currents are a common root cause of bearing failures in frequency converter-fed motors and generators. Bearing faults are typically identified by vibration measurements. In our work, we experimentally submit bearings to electric discharge machining (EDM) bearing currents, use different means to measure the electrical stress placed on the bearings, measure the resulting vibration signal, and apply signal processing for feature extraction. All this is done 1184 hours of operation, so as to study the incipient bearing failure behavior.