Assessment of the AMC-bioartificial liver in the anhepatic pig

被引:48
|
作者
Sosef, MN [1 ]
Abrahamse, LSL [1 ]
van de Kerkhove, MP [1 ]
Hartman, R [1 ]
Chamuleau, RAFM [1 ]
van Gulik, TM [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Surg, Surg Lab TWO 1 155, NL-1105 AZ Amsterdam, Netherlands
关键词
D O I
10.1097/00007890-200201270-00009
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The anhepatic pig model was used to evaluate a bioartificial liver developed in our institution (AMC-BAL). The bioartificial liver is based on oxygenated plasma perfusion of porcine hepatocytes attached to a polyester matrix. Methods. Pigs (n=15) underwent total hepatectomy with restoration of caval continuity using a polyethylene, three-way prosthesis. In group 1, pigs received limited intensive care under continuation of general anesthesia (n=5). Group II pigs (n=5) underwent, in addition, extracorporeal plasma perfusion of an AMC-BAL without hepatocytes (device control group). In group III (n=5), plasma perfusion occurred with an AMC-BAL loaded with autologous hepatocytes. Groups II and III were connected to the extracorporeal system 24 hr after hepatectomy, for a period of 24 hr. The main outcome parameters were as follows: survival time, liver enzymes (aspartate aminotransferase, alanine aminotransferase), blood ammonia, and total/direct bilirubin. Results. Survival (mean +/- SD) of the anhepatic pigs was significantly increased in the BAL-treated group (group III: 65+/-15 hr), as compared with the control groups (group I: 46+/-6 hr and group II: 43+/-14 hr). Mean blood ammonia levels during BAL treatment were significantly lower in the BAL-treated group in comparison with both control groups (P=0.02). Total and direct bilirubin levels gradually increased after hepatectomy and reached maximum values of 1.98 mg/dl and 1.50 mg/dl, respectively, showing no differences between the three groups. Conclusions. (1) Treatment of anhepatic pigs with the AMC-BAL containing autologous hepatocytes significantly increases survival time, which is associated with a significant decrease in blood ammonia. 2) Anhepatic pigs demonstrate increasing direct bilirubin levels as a result of extrahepatic bilirubin conjugation.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [31] Haemodynamic changes in ischaemic vs. anhepatic pig experimental model of acute liver failure
    Theodoraki, K
    Kostopanagiotou, G
    Smyrniotis, V
    Arkadopoulos, N
    Prachalias, A
    Pyrsopoulos, N
    Papadimitriou, J
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2002, 19 (01) : 40 - 46
  • [32] Short term cultivation of primary pig hepatocates in a bioartificial liver support system
    Lubei, Verena
    Wurm, Martin
    Tetta, Ciro
    Caronna, Marco
    Margreiter, Raimund
    Hengster, Paul
    XENOTRANSPLANTATION, 2007, 14 (05) : 534 - 534
  • [33] In vitro functional assessment of a porcine hepatocytes based bioartificial liver
    Donini, A
    Baccarani, U
    Risaliti, A
    Sanna, A
    Degrassi, A
    Bresadola, F
    TRANSPLANTATION PROCEEDINGS, 2001, 33 (7-8) : 3477 - 3479
  • [34] Bioartificial liver based on porcine hepatocyte: In vitro functional assessment
    Corno, V
    Donini, A
    Vianello, V
    Gonano, C
    Bonfreschi, V
    Pasqualotto, A
    Risaliti, A
    Belvedere, O
    Degrassi, A
    Bresadola, F
    TRANSPLANTATION PROCEEDINGS, 1998, 30 (05) : 2469 - 2470
  • [35] Bioartificial liver support
    Bain, VG
    Montero, JL
    de la Mata, M
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2001, 15 (05): : 313 - 318
  • [36] No septical complications in an anhepatic pig model with prolonged survival
    Etspueler, Alexander M. P.
    Thiel, Christian T.
    Knubben, Karolin M.
    Morgalla, Matthias H.
    Koenigsrainer, Alfred
    Schenk, Martin
    TRANSPLANT INTERNATIONAL, 2007, 20 : 296 - 296
  • [37] The Amsterdam bioartificial liver
    Chamuleau, RAFM
    ARTIFICIAL LIVER SUPPORT, 2006, 145 : 61 - 71
  • [38] Is there a future for the bioartificial liver?
    Brophy, Colleen M.
    Nyberg, Scott L.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2006, 11 (03) : 219 - 225
  • [40] Standardization of ischemic hepatic failure in pigs as a model for bioartificial liver assessment
    Miyashita, T
    Enosawa, S
    Tanaka, H
    Tamura, A
    Amemiya, H
    Aoki, T
    Koyanagi, Y
    Suzuki, S
    SURGERY TODAY, 2003, 33 (10) : 743 - 750