Handheld metal detector localization of ingested metallic foreign bodies -: Accurate in any hands?

被引:33
|
作者
Seikel, K
Primm, PA
Elizondo, BJ
Remley, KL
机构
[1] Univ Texas, SW Med Ctr, Dept Pediat, Dallas, TX 75235 USA
[2] Eastern Virginia Med Sch, Dept Pediat, Norfolk, VA 23501 USA
来源
关键词
D O I
10.1001/archpedi.153.8.853
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To demonstrate the accuracy of handheld metal detectors (HHMDs) for identification and localization of ingested metallic foreign bodies when used by experienced and inexperienced investigators. Design: Prospective study comparing HHMD scanning with radiography: Setting and Patients: A consecutive sample of all eligible patients (N = 176) presenting to the emergency departments of Children's Medical Center of Dallas, Dallas, Tex, and Children's Hospital of the King's Daughters, Norfolk, Va, who were known or suspected to have ingested a metallic foreign body. Intervention: Each patient under-went HHMD scanning and radiographic evaluation Main outcome Measures: Statistical evaluation compared HHMD scanning with radiography and experienced vs inexperienced investigator HHMD scanning to determine the accuracy of the screening tool and investigators. Results: Experienced investigators performed HHMD scans on 140 subjects; inexperienced investigators scanned all subjects. Disease was defined as a foreign body in the esophagus on radiograph. The 3 experienced investigators demonstrated sensitivity of 100% (95% confidence interval [CI], 94%-100%), specificity of 92.4% (95% CI, 84.2%-97.2%), positive predictive value (PPV) of 90.9% (95% CI, 81.3%-96.6%), and negative predictive value (NPV) of 100% (95% CI, 95.1%-100%); the proportion correct was 95.7% (95% CI, 90.8%-98.4%). The inexperienced investigators demonstrated sensitivity of 95.7% (95% CI, 88.0%-99.1%), specificity of 81.0% (95% CI, 72.1%-88.0%), PPV of 77.0% (95% CI, 66.8%-85.4%), and NPV of 96.6% (95% CI, 90.4%-99.3%); the proportion correct was 86.9% (95% CI, 80.9%-91.5%). The McNemar test demonstrated no statistically significant difference between HHMD scanning by experienced vs inexperienced investigators. Conclusions: Handheld metal detector scanning is an accurate, inexpensive, radiation-free screening tool and should be used for evaluation of patients suspected of ingesting coins and coinlike foreign bodies.
引用
收藏
页码:853 / 857
页数:5
相关论文
共 43 条
  • [21] PERFORATIONS OF THE SMALL INTESTINE BY INGESTED NON-METALLIC FOREIGN BODIES
    WADE, H
    BRITISH MEDICAL JOURNAL, 1952, 2 (4790): : 922 - 922
  • [22] Stomach full of ingested foreign bodies: More than a "metallic taste"
    Kilciler, Guldem
    Kantarcioglu, Murat
    Turan, Ilker
    Uygun, Ahmet
    Bagci, Sait
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2010, 21 (03): : 322 - 323
  • [23] Detection of coins ingested by children using a handheld metal detector: a systematic review
    Lee, JB
    Ahmad, S
    Gale, CP
    EMERGENCY MEDICINE JOURNAL, 2005, 22 (12) : 839 - 844
  • [24] Metal detector and swallowed metal foreign bodies in children
    Doraiswamy, NV
    Baig, H
    Hallam, L
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1999, 16 (02): : 123 - 125
  • [25] Detection of metallic ocular foreign bodies with handheld sonography in a porcine model
    Shiver, SA
    Lyon, M
    Blaivas, M
    JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (10) : 1341 - 1346
  • [26] Use of a commercially available metal detector for the localization of metallic foreign body ingestion in children
    Gooden, EA
    Forte, V
    Papsin, B
    JOURNAL OF OTOLARYNGOLOGY, 2000, 29 (04): : 218 - 220
  • [27] X-ray detection of ingested non-metallic foreign bodies
    Miguel Saps
    John M Rosen
    Jacob Ecanow
    World Journal of Clinical Pediatrics, 2014, 3 (02) : 14 - 18
  • [28] Removal of ingested metallic foreign bodies from children by orogastric magnetic tube
    Gurpinar, AN
    Kilic, N
    Dogruyol, H
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (5-6) : 469 - 471
  • [29] Localising ingested metallic foreign bodies to guide surgical planning: A novel use for the CT metal artefact reduction algorithm
    Abernethy, Peter
    McIntyre, Neil G.
    Sanchez-Cabello, Alexander
    Kruger, Ross
    Shetty, Dushyant
    BJR CASE REPORTS, 2021, 7 (05):
  • [30] A contribution to the localization of foreign bodies - A combined roentgenoscopic method for quick and accurate localization
    Gilbert, RJ
    Hertenstein, HU
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1941, 45 : 768 - 773