High-repetition-rate 12 fs pulse amplification by a Ti:sapphire regenerative amplifier system

被引:21
|
作者
Takada, H [1 ]
Kakehata, M [1 ]
Torizuka, K [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058568, Japan
关键词
D O I
10.1364/OL.31.001145
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate the direct generation of 12 fs pulses from a Ti :sapphire regenerative amplifier system at a 1 kHz repetition rate utilizing properly designed broadband components for chirped-pulse amplification. Optimized designs of a regenerative amplifier with a multilayer gain-narrowing compensator and an adaptive dispersion compensator with a spatial light modulator contribute to the shorter pulse amplification. (c) 2006 Optical Society of America.
引用
收藏
页码:1145 / 1147
页数:3
相关论文
共 50 条
  • [41] HIGH-REPETITION-RATE FEMTOSECOND MIDINFRARED PULSE GENERATION
    DEBARROS, MRX
    MIRANDA, RS
    JEDJU, TM
    BECKER, PC
    OPTICS LETTERS, 1995, 20 (05) : 480 - 482
  • [42] Compact high-repetition-rate pseudospark pulse generator
    Wang, F
    Kuthi, A
    Wang, XD
    Gundersen, M
    Proceedings of the 26th International Power Modulator Symposium and 2004 High Voltage Workshop, Conference Record, 2004, : 137 - 140
  • [43] HIGH-REPETITION-RATE FEMTOSECOND PULSE GENERATION IN THE BLUE
    ELLINGSON, RJ
    TANG, CL
    OPTICS LETTERS, 1992, 17 (05) : 343 - 345
  • [44] 0.09-terawatt pulses with a 31% efficient, kilohertz repetition-rate Ti:sapphire regenerative amplifier
    Yang, JZH
    Walker, BC
    OPTICS LETTERS, 2001, 26 (07) : 453 - 455
  • [45] CHIRPED PULSE AMPLIFICATION OF 300-FS PULSES IN AN ALEXANDRITE REGENERATIVE AMPLIFIER
    PESSOT, M
    SQUIER, J
    BADO, P
    MOUROU, G
    HARTER, DJ
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1989, 25 (01) : 61 - 66
  • [46] 12-fs pulses from a continuous-wave-pumped 200-nJ Ti:sapphire amplifier at a variable repetition rate as high as 4 MHz
    Huber, R
    Adler, F
    Leitenstorfer, A
    Beutter, M
    Baum, P
    Riedle, E
    OPTICS LETTERS, 2003, 28 (21) : 2118 - 2120
  • [47] High-repetition-rate, high-average-power, mode-locked Ti:sapphire laser with an intracavity continuous-wave amplification scheme
    Liu, ZL
    Izumida, S
    Ono, S
    Ohtake, H
    Sarukura, N
    APPLIED PHYSICS LETTERS, 1999, 74 (24) : 3622 - 3623
  • [48] High-repetition-rate chirped-pulse-amplification thin-disk laser system with joule-level pulse energy
    Tuemmler, J.
    Jung, R.
    Stiel, H.
    Nickles, P. V.
    Sandner, W.
    OPTICS LETTERS, 2009, 34 (09) : 1378 - 1380
  • [49] RECENT ADVANCES OF THE TI-SAPPHIRE-PUMPED HIGH-REPETITION-RATE FEMTOSECOND OPTICAL PARAMETRIC OSCILLATOR
    POWERS, PE
    ELLINGSON, RJ
    PELOUCH, WS
    TANG, CL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1993, 10 (11) : 2162 - 2167
  • [50] HIGH-REPETITION-RATE CW-PUMPED CR3+LISRALF6 FEMTOSECOND REGENERATIVE AMPLIFIER
    BALEMBOIS, F
    GEORGES, P
    SALIN, F
    BRUN, A
    OPTICS LETTERS, 1993, 18 (15) : 1250 - 1252