Performance characteristics of ejector expander transcritical CO2 refrigeration cycle

被引:28
|
作者
Ersoy, H. Kursad [1 ]
Bilir, Nagihan [1 ]
机构
[1] Selcuk Univ, Dept Mech Engn, Fac Engn & Architecture, TR-42250 Konya, Turkey
关键词
Suction nozzle; pressure drop; ejector; expansion; turbine; coefficient of performance; exergy; 2-PHASE EJECTOR; EXERGY;
D O I
10.1177/0957650912446547
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects on the performance of the basic CO2 refrigeration cycle when using an ejector as the expander to recover expansion work were investigated. A two-phase constant area ejector flow model was used in the ejector analysis. The coefficient of cooling performance and gas cooler pressure that yielded the maximum exergy efficiency, suction nozzle pressure drop, and optimum values for the ejector area ratio were determined for various evaporator and gas cooler outlet temperatures. Parametric studies were performed using engineering equation solver. The suction nozzle pressure drop had a significant effect on the ejector area ratio, coefficient of cooling performance, and exergy efficiency. It is necessary to design an ejector with the optimum area ratio to achieve the optimum pressure drop and maximum performance. Cycle that use the ejector as an expander always has higher coefficient of performance and exergy efficiency than conventional cycle under any operating condition. The irreversibility decreases compared to the classic refrigeration cycle when the ejector or turbine are used as an expander. The analysis results showed that - under a gas cooler pressure of 9.5 MPa, gas cooler outlet temperature of 40 degrees C, evaporator temperature of 5 degrees C, and cooling capacity of 3.5kW - the total irreversibility of the ejector system was lower than those of the basic and turbine expander systems by 39.1% and 5.46%, respectively.
引用
收藏
页码:623 / 635
页数:13
相关论文
共 50 条
  • [21] Cycle improvements to ejector-expansion transcritical CO2 two-stage refrigeration cycle
    Yari, M.
    Sirousazar, M.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (07) : 677 - 687
  • [22] Thermodynamic Analysis of Transcritical CO2 Ejector Expansion Refrigeration Cycle with Dedicated Mechanical Subcooling
    Fu, Ruansong
    Wang, Jinhui
    Zheng, Minfeng
    Yu, Kaihong
    Liu, Xi
    Li, Xuelai
    [J]. ENTROPY, 2019, 21 (09)
  • [23] Performance optimization of transcritical CO2 refrigeration cycle with thermoelectric subcooler
    Sarkar, Jahar
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (02) : 121 - 128
  • [25] Dynamic model of a transcritical CO2 ejector expansion refrigeration system
    Zheng, Lixing
    Deng, Jianqiang
    He, Yang
    Jiang, Peixue
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 : 247 - 260
  • [26] EXPERIMENTAL COMPARISON OF THE PERFORMANCE OF A CO2 EJECTOR CYCLE FOR TRANSCRITICAL AND SUBCRITICAL OPERATION
    Lawrence, N.
    Elbel, S.
    [J]. 12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 527 - 534
  • [27] Thermodynamic analysis and optimization of novel ejector-expansion TRCC (transcritical CO2) cascade refrigeration cycles (Novel transcritical CO2 cycle)
    Yari, Mortaza
    Mahmoudi, S. M. S.
    [J]. ENERGY, 2011, 36 (12) : 6839 - 6850
  • [28] Theoretical evaluation on effect of internal heat exchanger in ejector expansion transcritical CO2 refrigeration cycle
    Zhang, Zhen-ying
    Ma, Yi-tai
    Wang, Hong-li
    Li, Min-xia
    [J]. APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 932 - 938
  • [29] Dynamic simulation on operating modes of ejector in transcritical CO2 ejector expansion refrigeration cycles
    Zheng, Lixing
    Deng, Jianqiang
    He, Yang
    Jiang, Peixue
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (01) : 15 - 29
  • [30] Performance analysis of a modified dual-ejector and dual-evaporator transcritical CO2 refrigeration cycle for supermarket application
    Liu, Jiarui
    Liu, Ye
    Yu, Jianlin
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 109 - 118