A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

被引:0
|
作者
Mousavi, Syed Husain Hashemi [1 ]
Kobarfard, Farzad [2 ]
Husain, Syed Waqif [1 ]
Tehrani, Mohammad Saber [1 ]
Azar, Parviz Abroomand [1 ]
Ahmadkhaniha, Reza [3 ]
Mehdizadeh, Amir [4 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Chem, Tehran, Iran
[2] SBMU, Phytochem Res Ctr, Dept Med Chem, Sch Pharm, Tehran, Iran
[3] Univ Tehran Med Sci, Pharmacut Sci Res Ctr, Tehran, Iran
[4] Kimia R&D Inst, Tehran, Iran
来源
关键词
Electrospray ionization (ESI); Finasteride; Ion trap; Liquid chromatography-mass spectrometry (LC-MS); Pharmacokinetic; BIOLOGICAL-FLUIDS; PICOGRAM; SEPARATION; EXTRACTION;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse (R) C-8 analytical column using a mobile phase consisted of acetonitrile, 2 mM ammonium formate buffer (58:42, pH adjusted at 2.5 using formic acid); the flow rate was 0.25 mLmin(-1) and the column oven was set to 50 degrees C. Tamoxifen citrate was used as internal standard. This method involved the use of [M +H] ions of finasteride and IS at m/z 373 and 372 respectively with the selected ion monitoring (SIM) mode. The calibration curve was linear over the range of 0.1-60 ng mL(-1). The limit of quantification for finasteride in plasma was 0.1 ng mL(-1). The intra-day and inter-day repeatability (precision) were 2.68-13.87% and 2.14-14.69% respectively. Intra-day and inter-day accuracy were 98-101.57% and 99.7-110%. The assay method has been successfully used to estimate the pharmacokinetics of finasteride after oral administration of a 5 mg tablet of finasteride in 12 healthy volunteers.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 50 条
  • [31] Quantitative determination of rhein in human plasma by liquid chromatography-negative electrospray ionization tandem mass/mass spectrometry and the application in a pharmacokinetic study
    Jiang, Jun-yi
    Yang, Ming-wei
    Qian, Wei
    Lin, Hui
    Geng, Yan
    Zhou, Zhi-qun
    Xiao, Da-wei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 57 : 19 - 25
  • [32] Highly sensitive method for the determination of omeprazole in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study
    Vittal, Shivva
    Ganneboina, Ramesh
    Layek, Buddhadev
    Trivedi, Ravi Kumar
    Hotha, Kishore Kumar
    Bharathi, D. Vijaya
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (04) : 390 - 396
  • [33] Simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method for the quantification of lacidipine in human plasma
    Ramakrishna, NVS
    Vishwottam, KN
    Puran, S
    Manoj, S
    Santosh, M
    Koteshwara, M
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (07): : 824 - 832
  • [34] Determination of midazolam and its hydroxy metabolites in human plasma and oral fluid by liquid chromatography/electrospray ionization ion trap tandem mass spectrometry
    Link, Bettina
    Haschke, Manuel
    Wenk, Markus
    Kraehenbuehl, Stephan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (09) : 1531 - 1540
  • [35] Liquid chromatography-electrospray ionization-mass spectrometric method for the determination of hydrochlorothiazide in human plasma: Application to a pharmacokinetic study
    Li, Lin
    Sun, Jin
    Yang, Ping
    He, Zhonggui
    ANALYTICAL LETTERS, 2006, 39 (15) : 2797 - 2807
  • [36] Liquid chromatography/negative ion electrospray tandem mass spectrometry method for the quantification of rosuvastatin in human plasma: Application to a pharmacokinetic study
    Gao, Jun
    Zhong, Dafang
    Duan, Xiaotao
    Chen, Xiaoyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 35 - 40
  • [37] Determination and pharmacokinetic study of amlodipine in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry
    Ma, Yuanyuan
    Qin, Feng
    Sun, Xiaohong
    Lu, Xiumei
    Li, Famei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1540 - 1545
  • [38] Simultaneous determination of phentermine and topiramate in human plasma by liquid chromatography-tandem mass spectrometry with positive/negative ion-switching electrospray ionization and its application in pharmacokinetic study
    Ni, Yang
    Zhou, Ying
    Xu, Mingzhen
    He, Xiaomeng
    Li, Huqun
    Haseeb, Satter
    Chen, Hui
    Li, Weiyong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 107 : 444 - 449
  • [39] Determination of finasteride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry with flow rate gradient
    Yuan, Lihua
    Ding, Meijuan
    Ma, Jing
    Xu, Jinhui
    Wu, Xiaoli
    Feng, Jing
    Shen, Fei
    Zhou, Xuemin
    EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 2011, 35 (3-4) : 137 - 146
  • [40] Determination of vinflunine in rat plasma by liquid chromatography-electrospray ionization mass spectrometry for a pharmacokinetic study
    Zhao, Xiaoping
    Liu, Xiaoquan
    Wang, Yongsheng
    Zhong, Jiao
    Chen, Yan
    Wang, Guangji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 906 - 911